8. LW3 Programmers' Reference
Hybrid Modular Matrix Switcher series – User's Manual
68
Applied firmware package: v1.0.0 | LDC software: v2.4.0b3
8.4.
System Commands
8.4.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
#producttype
ç
GET·/.ProductName
æ
pr·/.ProductName=
<Product_name>
Example
ç
GET /.ProductName
æ
pr /.ProductName=MX2M-FR24R
8.4.2.
Set the Device Label
INFO:
The device label can be changed to a custom text in the
tab of the LDC software. This
writable parameter is not the same as the ProductName parameter.
Command and Response
#devicelabel #label
ç
SET·/MANAGEMENT/LABEL/DeviceLabel=
<Custom_name>
æ
pw·/MANAGEMENT/LABEL/DeviceLabel=
<Custom_name>
The Device Label can be 39 character length and ASCII characters are allowed. Longer names are truncated.
Example
ç
SET /MANAGEMENT/LABEL.DeviceLabel=MX2M_Conference
æ
pw /MANAGEMENT/LABEL.DeviceLabel=MX2M_Conference
8.4.3. Query the Serial Number
Command and Response
#serialnumber
ç
GET·/.SerialNumber
æ
pr·/.SerialNumber=
<serial_number>
Example
ç
GET /.SerialNumber
æ
pr /.SerialNumber=87654321
8.4.4. Query the Firmware Version
Command and Response
#firmwareversion
ç
GET·/MANAGEMENT/UID/PACKAGE.Version
æ
pr·/MANAGEMENT/UID/PACKAGE.Version=
<firmware_version>
Example
ç
GET /MANAGEMENT/UID/PACKAGE.Version
æ
pr /MANAGEMENT/UID/PACKAGE.Version=1.0.0b20
8.4.5. Query the Date and Time of the System
The query returns with the current date and time which is set in the matrix. The format is based on the
ISO 8601 standard.
Command and Response
#time #date
ç
GET·/MANAGEMENT/DATETIME.CurrentTime
æ
pr·/MANAGEMENT/DATETIME.CurrentTime=
<date_time>
Parameters
Parameter
Description
Formula
<date_time>
Current date and time
YYYY
-
MM
-
DD
T
HH
:
MM
:
SS
Example
ç
GET /MANAGEMENT/DATETIME.CurrentTime
æ
pr /MANAGEMENT/DATETIME.CurrentTime=2020-09-01T17:38:37
8.4.6.
Setting of the Date and Time Manually
The date and time format is based on the ISO 8601 standard.
Command and Response
ç
CALL·/MANAGEMENT/DATETIME:setTime=
<date_time>
æ
mO·/MANAGEMENT/DATETIME:setTime=
Parameters
Parameter
Description
Formula
<date_time>
Current date and time
YYYY
-
MM
-
DD
T
HH
:
MM
:
SS
Example
ç
CALL /MANAGEMENT/DATETIME:setTime=2020-12-24T20:00:15
æ
mO /MANAGEMENT/DATETIME.setTime=