7. LW3 Programmers’ Reference
MODEX-F15-OPTS, MODEX-F15-OPTM series – User's Manual
56
7.5.
System Commands
7.5.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command format:
GET
●
/.ProductName
Response format:
pr
●
/.ProductName=<Product_name>
Example:
˃
GET
/.ProductName
˂
pr
/.ProductName=MEX-110-***-410-715-721
7.5.2. Query the Serial Number
Command format:
GET
●
/.SerialNumber
Response format:
pr
●
/.SerialNumber=<serial_nr>
Example:
˃
GET
/.SerialNumber
˂
pr
/.SerialNumber=00004550
7.5.3. Query the Firmware Version
Command format:
GET
●
/SYS/MB.FirmwareVersion
Response format:
pr
●
/SYS/MB.FirmwareVersion=<firmware_version>
Example:
˃
GET /SYS/MB.FirmwareVersion
˂
pr /SYS/MB.FirmwareVersion=2.1.1b2 r30
7.5.4.
Set the Background Light of the LCD Screen
Command format:
SET
●
/MANAGEMENT/UI.LcdMenuBackLightMode=0|1|2
Response format:
pw
●
/MANAGEMENT/UI.LcdMenuBackLightMode=0|1|2
Example:
˃
SET /MANAGEMENT/UI.LcdMenuBackLightMode=0
˂
pw /MANAGEMENT/UI.LcdMenuBackLightMode=0
Parameters:
0
: background light:
OFF
/
1
: background light:
ON / 2
: background light:
BLINKING
7.5.5.
Set the Displayed Text on the LCD Screen
Two-line long message can be displayed on the LCD screen.
Command format:
CALL
●/MANAGEMENT/UI:LcdMenuMessage(<time>;<1stline_text>;<2ndline_text>)
Response format:
mO
●
/MANAGEMENT/UI:LcdMenuMessage
Example:
˃
CALL /MANAGEMENT/UI:LcdMenuMessage(100;first line;second line)
˂
mO /MANAGEMENT/UI:LcdMenuMessage
Parameters:
<time>:
The displayed text is shown a definite time (100 means 1 second.)
<1stline_text>;<2ndline_text>:
The displayed text can be 19 character length and ASCII characters are
allowed. Longer names are truncated.
7.5.6.
Resetting the Extender
The matrix can be restarted – the current connections (LAN, RS-232) will be terminated.
Command format:
CALL
●
/SYS:reset()
Response format:
mO
●
/SYS:reset=
Example:
˃
CALL
/SYS:reset()
˂
mO
/SYS:reset=
7.5.7.
Restore the Factory Default Settings
Command format:
CALL
●
/SYS:factoryDefaults()
Response format:
mO
●
/SYS:factoryDefaults=
Example:
˃
CALL
/SYS:factoryDefaults()
˂
mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the