4. Installation
MMX8x4-HT series – User's Manual
28
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
4.1.
Mounting Options -Standard Rack Installation
The matrix can be mounted in several ways by the supplied two rack ears. Allen head screws fix them to the
housing.
ATTENTION!
M4x10 size is the longest allowed screw for fixing the ears to the housing. A longer screw
may touch internal parts.
Two rack ears are supplied with the product, which are fixed on left and right side as shown in the picture.
The default position allows mounting the device as a standard rack unit installation.
Standard rack installation
ATTENTION!
Always use all the four screws for fixing the rack shelf ears to the rack rail. Choose properly
sized screws for mounting. Keep minimum two threads left after the nut screw.
Mounting the device to the rack rail
INFO: The matrix switcher is one rack wide and 2U high.
WARNING! Never block the ventilation holes on any side of the matrix! Ensure the proper ventilation by
letting the free airflow.
Direction of the airflow