3. Front Panel Control
MMX8x4-HT series – User's Manual
20
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
3.2.1.
System Settings Menu
Network Submenu
#dhcp #ipaddress #network
The parameters of the network connection can be set in this submenu. IP, Subnet,
Gateway and MAC parameters show the current settings. If the DHCP option is
disabled, three more parameters are listed which can be set for a static IP address:
▪
Static IP,
▪
Static Subnet,
▪
Static Gateway.
ATTENTION!
If you change the network settings, always press the Save option under Network menu (not
only in the submenu of the parameter) to apply the new settings.
RS-232 Submenu
#rs232 #rs-232
When entering the submenu the available serial ports are listed. Select the desired
port and enter to see the settings.
Adjustable parameters of the serial ports:
▪
Mode (Disconnect/ Control/ Command injection),
▪
Baud Rate* (4800/ 7200/ 9600/ 14400/ 19200/ 38400/ 57600/ 115200)
▪
Protocol (LW2/ LW3).
*At Mixed IR /TTL serial port, only this setting is available.
Front Panel Submenu
The following front panel-related parameters can be set in this submenu:
▪
Display Backlight (1-10)
The brightness of the LCD can be set from 1 to 10 on a scale.
▪
Rotary Direction (CW Down/ CCW Down)
Device Info Submenu
#firmwareversion
In this submenu you can check basic information about the matrix unit:
▪
Serial number
▪
Hardware Version
▪
Firmware Version
Factory Defaults Submenu
#factory
Factory default settings will be restored by choosing
Yes
.
Reset Device Submenu
#restart
There is a possibility to reset the device.
Bootload Mode Submenu
#bootload
Special function for entering the bootload mode.