7.9.7. Query the Command Injection Mode
Command and Response
ç
GET·/MEDIA/UART/
<port>
.CommandInjectionStatus
æ
pr·/MEDIA/UART/
<port>
.CommandInjectionStatus=
<logical_value>
Parameters
Identifier
Parameter description
Value
Parameter value
<logical_value>
Command injection mode
status
true
Command injection mode is enabled.
false
Command injection mode is disabled.
Example
ç
SET /MEDIA/UART/P1.CommandInjection=true
æ
pw /MEDIA/UART/P1.CommandInjectionEnable=true
7.9.8.
Change the Command Injection Mode
Command and Response
ç
SET·/MEDIA/UART/
<port>
.CommandInjectionEnable=
<logical_value>
æ
pw·/MEDIA/UART/
<port>
.CommandInjectionEnable=
<logical_value>
Parameters
Identifier
Parameter description
Value
Parameter value
<logical_value>
Command injection mode
setting
true
Command injection mode is enabled.
false
Command injection mode is disabled.
Example
ç
SET /MEDIA/UART/P1.CommandInjectionEnable=true
æ
pw /MEDIA/UART/P1.CommandInjectionEnable=true
ATTENTION!
The local RS-232 and TPS serial link are mirrored. If you change the RS-232 mode on P1
(local) port, the P2 (TPS serial link) will also be changed.
7.10.
RS-232 Recognizer
This tool is able to recognize the incoming RS-232 message. It stores the incoming serial data from the first
bit, until the previously defined string (delimiter) or the elapsing timeout after the last bit. The last incoming
serial string is saved in different formats (string, hex, and hash).
7.10.1.
Enable the Recognizer
ç
SET·/MEDIA/UART/
<port>
.RecognizerEnable=
<logical_value>
æ
pw·/MEDIA/UART/
<port>
.RecognizerEnable=
<logical_value>
Parameters
Identifier
Parameter description
Value
Parameter value
<logical_value>
Recognizer enable/
disable setting
true
Enabled
false
Disabled
Example
ç
SET /MEDIA/UART/P1.RecognizerEnable=true
æ
pw /MEDIA/UART/P1.RecognizerEnable=true
7.10.2.
Set the Delimiter Hex
When the delimiter hex string is detected in the incoming serial
data, the device saves the RS-232 message data from the first
bit, until the delimiter (or the data between the two delimiter).
ç
SET·/MEDIA/UART/RECOGNIZER.DelimiterHex=
<delimiter
>
æ
pw·/MEDIA/UART/RECOGNIZER.DelimiterHex=
<delimiter>
Parameters
<delimiter>
It can be max. 8-character long (or 16 hex digit) in
hex
format.
Example
ç
SET /MEDIA/UART/RECOGNIZER.DelimiterHex=3a
æ
pw /MEDIA/UART/RECOGNIZER.DelimiterHex=3a
... Password :
Login name :
...
Delimiter (hex format: 3A)