
7. LW3 Programmer's Reference
HDMI-TPS-RX220AK – User's Manual
78
Applied firmware package: v1.4.0 | LDC software: v2.4.0b3
7.5.20.
HDCP Setting (Output Port)
HDCP capability can be set to Auto/Always on the output ports, thus, non-encrypted content can be
transmitted to a non-HDCP compliant display. See more information in the
Command and Response
#hdcp
ç
SET·/MEDIA/VIDEO/
<out>
.HdcpModeSetting=
<HDCP_mode>
æ
pw·/MEDIA/VIDEO/
<out>
.HdcpModeSetting=
<HDCP_mode>
Parameters
Identifier
Parameter description
Value
Parameter value
<HDCP_mode>
HDCP mode
0
Auto
1
Always
Example
ç
SET /MEDIA/VIDEO/O1.HdcpModeSetting=0
æ
pw /MEDIA/VIDEO/O1.HdcpModeSetting=0
7.5.21.
Test Pattern Generator Mode
The output port can send a special image towards the sink device for testing purposes. The setting is
available on the input ports with the below-listed parameters.
Command and Response
#testpattern #nosyncscreen #diagnostic
ç
SET·/MEDIA/VIDEO/
<out>
.TpgMode=
<mode>
æ
pw·/MEDIA/VIDEO/
<out>
.TpgMode=
<mode>
Parameters
Identifier
Parameter description
Value
Parameter value
<mode>
Test pattern generator
mode
0
Always off
: the test pattern is not displayed on
the output.
1
Always on
: the test pattern is displayed on the
output.
2
Auto
: the test pattern is displayed if there is no
signal on the input port.
Example
ç
SET /MEDIA/VIDEO/O1.TpgMode=2
æ
pw /MEDIA/VIDEO/O1.TpgMode=2
7.5.22.
Test Pattern Generator Clock Source
Command and Response
ç
SET·/MEDIA/VIDEO/
<out>
.TpgClockSource=
<clock_frequency>
æ
pw·/MEDIA/VIDEO/
<out>
.TpgClockSource=
<clock_frequency>
Parameters
Identifier
Parameter description
Value
Parameter value
<clock_frequency>
Clock frequency
480
480p
576
576p
EXT
External clock (from actual TMDS source)
Example
ç
SET /MEDIA/VIDEO/O1.TpgClockSource=576
æ
pw /MEDIA/VIDEO/O1.TpgClockSource=576
7.5.23.
Test Pattern Setting
Command and Response
ç
SET·/MEDIA/VIDEO/
<out>
.TpgPattern=
<pattern>
æ
pw·/MEDIA/VIDEO/
<out>
.TpgPattern=
<pattern>
Parameters
Identifier
Parameter description
Value
Parameter value
<pattern>
The test pattern displayed
on the sink device
RED
Red
GREEN
Green
BLUE
Blue
BLACK
Black
WHITE
White
RAMP
Ramp
CHESS
Chess
BAR
Bar
CYCLE
Cycle setting means all the patterns are
changed sequentially approx. in every 2
seconds
Example
ç
SET /MEDIA/VIDEO/O1.TpgPattern=GREEN
æ
pw /MEDIA/VIDEO/O1.TpgPattern=GREEN