6. LW2 Programmer's Reference
HDMI-TPS-RX220AK – User's Manual
63
Applied firmware package: v1.4.0 | LDC software: v2.4.0b3
6.5.6. Gateway Address Query
Gateway address can be queried as follows.
Command and Response
ȩ
{IP_GATEWAY=?}
Ȩ
(IP_GATEWAY=
<gateway_address>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<gateway_address>
Current gateway address of
the device
Gateway address (four decimal
octets separated by dots).
Example
ȩ
{ip_gateway=?}
Ȩ
(IP_GATEWAY=192.168.0.1)
6.5.7.
Gateway Mask Setting
Gateway address can be set as follows.
Command and Response
ȩ
{IP_GATEWAY=
<gateway_address>
}
Ȩ
(IP_GATEWAY=
<gateway_address>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<gateway_address>
Current gateway address of
the device
Gateway address (four decimal
octets separated by dots).
Example
ȩ
{ip_gateway=192.168.0.1}
Ȩ
(IP_GATEWAY=192.168.0.1)
6.5.8.
Apply Network Settings
Applying the network settings and restart the network interface.
ATTENTION!
The command is always requires as the last step for applying the modified network settings.
Command and Response
ȩ
{IP_APPLY}
Ȩ
(IP_APPLY)CrLf
Example
ȩ
{ip_apply}
Ȩ
(IP_APPLY)
6.6.
RS-232 Settings
6.6.1.
RS-232 Mode Setting
RS -232 mode can be set as follows. See more details about RS -232 modes in the
#rs232 #rs-232 #serial #commandinjection #protocol
Command and Response
ȩ
{RS232=
<mode>
}
Ȩ
(RS232=
<mode>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<mode>
RS-232 operation mode
CONTROL
Control mode
CI
Command injection mode
PASS
Pass-through mode
Example
ȩ
{rs232=control}
Ȩ
(RS232=CONTROL)
INFO:
The current RS-232 mode can be queried by the {RS232=?} command.