7.LW3Programmers’Reference
HDMI-TPS-RX110AYseries–User'sManual
109
Appliedfirmwarepackage:v1.5.0b3 | LDCsoftware:v2.5.9b2
7.17.5.
Parity Setting
Command and Response
ç
SET·/MEDIA/UART/
<port>
.Parity=
<parity>
æ
pw·/MEDIA/UART/
<port>
.Parity=
<parity>
Parameters
Identifier
Parameter description
Value
Parameter value
<parity>
Parity setting
0
None
1
Odd
2
Even
Example
ç
SET/MEDIA/UART/P1.Parity=0
æ
pw/MEDIA/UART/P1.Parity=0
7.17.6.
RS-232 Operation Mode
Command and Response
ç
SET·/MEDIA/UART/
<port>
.Rs232Mode=
<mode>
æ
pw·/MEDIA/UART/
<port>
.Rs232Mode=
<mode>
Parameters
Identifier
Parameter description
Value
Parameter value
<stopbits>
Stopbits value
0
Pass-through
1
Control
2
Command injection
Example
ç
SET/MEDIA/UART/P1.Rs232Mode=1
æ
pw/MEDIA/UART/P1.Rs232Mode=1
7.17.7. Query the Command Injection Mode
Command and Response
ç
GET·/MEDIA/UART/
<port>
.CommandInjectionStatus
æ
pr·/MEDIA/UART/
<port>
.CommandInjectionStatus=
<logical_value>
Parameters
Identifier
Parameter description
Value
Parameter value
<logical_value>
Command injection mode
status
true
Command injection mode is enabled.
false
Command injection mode is disabled.
Example
ç
SET/MEDIA/UART/P1.CommandInjection=true
æ
pw/MEDIA/UART/P1.CommandInjectionEnable=true
7.17.8.
Change the Command Injection Mode
Command and Response
ç
SET·/MEDIA/UART/
<port>
.CommandInjectionEnable=
<logical_value>
æ
pw·/MEDIA/UART/
<port>
.CommandInjectionEnable=
<logical_value>
Parameters
Identifier
Parameter description
Value
Parameter value
<logical_value>
Command injection mode
setting
true
Command injection mode is enabled.
false
Command injection mode is disabled.
Example
ç
SET/MEDIA/UART/P1.CommandInjectionEnable=true
æ
pw/MEDIA/UART/P1.CommandInjectionEnable=true
ATTENTION!
The local RS-232 and TPS serial link are mirrored. If you change the RS-232 mode on P1
(local) port, the P2 (TPS serial link) will also be changed.