2. Product Overview
UMX-TPS-TX100 series – User's Manual
23
Applied firmware packages: (UMX-TPS): v1.5.0b4 | (WP-UMX-TPS): v1.4.0b8 | (FP-UMX-TPS): v1.4.0b8 | LDC software: v2.5.6b2
2.9.
Special Functions
2.9.1.
Programmable Show Me Button
Action or an operation can be assigned to the
Show Me
button as this button press is a condition
that can be selected in the Event Manager. See more details in the
section.
HighlightMe (Default Function)
DIFFERENCE:
This feature is available only from FW package v1.5.0b4.
This feature is to help finding the desired device in the Device discovery window of Lightware Device
Controller software. Press the
Show Me
button for
5 seconds
until the front panel LEDs start to blink slowly,
then release the button. In parallel, the device is
highlighted in green for 4 seconds
in the Device discovery
window of the LDC, see the
section.
2.9.2.
Enable DHCP (Dynamic) IP Address
The device has a static IP address as a factory default setting. If this setting does not fit
to the circumstances during install or usage, DHCP can be enabled from the front panel:
Step 1.
Make sure the device is powered on and operational.
Step 2.
Press and keep pressed the
Show Me
button for 5 seconds.
Step 3.
After 5 seconds front panel LEDs start blinking; release the button and press it 3 times again quickly
(within 3 seconds).
Step 4.
The LEDs get dark, DHCP gets enabled.
#network #dhcp
2.9.3.
Reset to Factory Default Settings
To restore factory default values, do the following steps:
Step 1.
Make sure the device is powered on and operational.
Step 2.
Press and keep pressed the
Show Me
button for 10 seconds. After 5 seconds front
panel LEDs start blinking but keep on pressing the button.
Step 3.
After 10 seconds the LEDs start blinking faster; release the button and press it 3 times again quickly
(within 3 seconds).
Step 4.
The LEDs get dark, the device restores the factory default settings and reboots.
Factory default settings are listed in the
section.
#factorydefault
2.9.4.
Reseting the Device
In few cases (after firmware update, etc) you may need to reset the
device. Pushing the reset button results the same as you disconnect
and reconnect the power adaptor to the transmitter. To reseting the
device follow the steps:
Step 1.
Push the button with a thin object for a second.
Step 2.
Wait until the device reboots. You can use the transmitter when the LIVE LED is blinking slowly again.
ATTENTION!
Reseting the device does not reset the settings to factory defaults. To reset factory default
settings see the previous section.
# reset # reboot #restart
SHOW
ME
5
sec
SHOW
ME
10
sec
SHOW
ME
SHOW
ME
AUDIO
SELECT
VIDEO
SELECT
RESET
2.9.5.
Control Lock
Press the
Audio Select
and
Show Me
buttons
together
(within 100 ms)
to disable/enable front panel buttons; front panel LEDs blink 4 times
when locking/unlocking. If the control lock is enabled and a button
is pressed, front panel LEDs blink 3 times.
#controllock
2.9.6.
Entering Firmware Update Mode
ATTENTION!
This function is applicable only in special cases when the device is to be updated by the
Lightware Device Updater (LDU) software. Do not use this option with LDU2 software.
It may happen that the firmware update process is not successful and the device cannot be
switched to bootload mode automatically. In this case, the device can be forced into firmware
update mode as follows:
Step 1.
Make sure the transmitter is powered off.
Step 2.
Press and keep pressed the
Show Me
button.
Step 3.
Power on the transmitter while the
Show Me
button is being pressed. If the device is switched to
firmware update mode the LIVE LED is blinking quickly (less than 500 ms duty cycle). The other LEDs
are off.
The procedure of firmware update can be found in the
chapter.
SHOW
ME
AUDIO
SELECT
VIDEO
SELECT
RESET
SHOW
ME