Lytespan
®
Track Lighting System
7531
Page 1 of 2
Dramalux
®
Wall Washer
Lightolier
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Job Information
Type:
12’ - 0” Ceiling Height - Track 66” from Wall*
0’
3.5
3.0
2.5
2.0
1.0
1.0
0.5
0.5
0.5
5.0
5.0
5.0
4.0
3.0
4.2
1’
5.5
5.0
4.0
3.0
1.5
1.0
0.5
0.5
0.5
7.5
7.5
7.5
6.0
3.5
6.2
2’
8.0
7.5
5.5
3.5
2.0
1.5
1.0
0.5
0.5
10.5 10.0 10.5
8.5
5.0
8.8
3’
9.0
8.5
7.0
4.5
2.5
1.5
1.0
1.0
0.5
12.0 12.0 12.0
9.5
5.5
9.5
4’
10.0 10.0
8.0
5.5
3.0
2.0
1.0
1.0
0.5
13.5 14.5 13.5
10.5
6.5
10.6
5’
12.5 12.0 10.0
6.5
3.5
2.0
1.0
1.0
0.5
17.0 17.5 17.0
13.5
8.0
13.4
6’
15.0 14.0 11.0
7.5
4.5
2.5
1.5
1.0
1.0
20.0 20.0 20.0
16.5
9.5
16.4
6.5’
15.0 14.0 11.0
8.0
4.5
3.0
1.5
1.0
0.5
21.5 20.5 21.5
16.5 10.0 16.4
7’
14.0 12.5 10.5
7.5
4.5
3.0
1.5
1.0
0.5
20.0 19.5 20.0
15.0
9.5
15.6
8’
12.5 11.5 10.0
7.0
4.0
3.0
1.5
1.5
0.5
18.5 18.0 18.5
13.5
9.0
13.6
9’
10.0
9.0
8.0
6.0
4.0
3.0
1.5
1.5
0.5
16.0 15.0 16.0
11.0
8.5
11.2
10’
8.5
8.0
7.0
5.0
4.0
3.0
1.5
1.5
0.5
14.0 13.5 14.0
19.5
8.5
19.6
11’
7.0
6.5
6.0
4.5
3.0
3.0
1.5
1.5
0.5
12.5 11.0 12.5
7.5
7.0
7.6
12’
5.5
5.0
4.2
3.0
3.0
2.0
1.5
1.5
0.5
9.5
8.5
9.5
6.0
6.5
6.2
Distance
From
Ceiling
66”
60º
62”
93”
12” 24” 36” 48” 60” 72” 84” 96”
Distance to Side of Unit
10’ - 0” Ceiling Height - Track 40” from Wall*
0’
6.0
5.0
2.5
2.5
2.0
1.0
0.5
0.0
12.0
9.5
12.0
7.5
6.0
7.5
1’
13.0 11.0
9.0
3.5
2.0
1.0
0.5
0.5
21.5 24.0 21.5
17.0 13.5 17.0
2’
23.0 18.0 12.0
4.5
3.0
1.0
0.5
0.5
32.5 33.0 32.5
26.0 18.0 26.0
3’
25.0 23.0 14.5
5.0
3.0
1.0
0.5
0.5
36.5 40.5 36.5
28.0 21.0 28.0
4’
33.0 27.0 15.0
6.0
2.5
1.0
0.5
0.5
48.0 45.0 48.0
36.0 22.5 36.0
4.5’
34.0 28.0 16.0
6.0
2.5
1.0
1.0
0.5
48.0 47.0 48.0
37.0 23.5 37.0
5’
28.0 25.0 15.0
6.0
2.5
1.5
1.0
0.5
41.0 43.0 41.0
31.5 22.0 31.5
6’
20.0 18.0 13.0
5.5
2.0
1.5
1.0
0.5
32.0 34.0 32.0
23.5 20.0 23.5
7’
15.0 13.0
9.0
4.0
1.5
1.5
1.0
1.0
25.0 25.0 25.0
18.0 14.5 18.0
8’
10.0
8.5
6.0
3.0
1.5
1.5
1.0
1.0
18.0 18.0 18.0
13.0 10.5 13.0
9’
8.0
7.0
4.5
2.0
1.5
1.5
1.0
1.0
14.0 14.0 14.0
11.0
8.5
11.0
10’
5.0
4.0
3.5
1.5
1.5
1.5
1.0
1.0
9.0
10.5
9.0
7.5
6.5
7.5
Distance
From
Ceiling
40”
60º
38”
57”
12” 24” 36” 48” 60” 72” 84”
Distance to Side of Unit
8’ - 0” Ceiling Height - Track 22” from Wall*
T
0’
11.0
6.5
5.5
3.0
2.0
1.5
1.0
0.5
0.5
19.5 16.5 19.5
15.0 10.5 15.0
1’
70.0 65.0 34.0 12.0
5.5
3.0
1.5
1.0
1.0
97.0 109.5 97.0
80.0 48.5 80.0
2’
115.0 110.0 66.0 26.0
9.0
3.5
2.0
1.0
1.0
171.0 190.5 171.0
129.0 95.0 129.0
2.5’
140.0 130.0 80.0 36.0 14.0
4.5
2.5
1.5
1.0
217.0 231.0 217.0
160.0 120.0 160.0
3’
120.0 115.0 77.0 39.0 16.5
6.0
2.5
1.5
1.5
203.0 217.0 203.0
144.0 120.0 144.0
4’
48.0 48.0 40.0 24.0 14.0
7.5
3.0
2.0
1.5
102.0 113.0 102.5
71.0 69.0 71.0
5’
17.0 17.0 16.0 11.5
8.5
5.5
3.0
2.0
1.5
46.5 51.0 46.5
33.0 32.5 33.0
6’
8.0
7.0
8.0
6.0
5.0
3.5
2.8
2.0
1.5
25.5 27.0 25.5
18.5 18.5 18.5
7’
4.0
4.0
5.0
3.5
3.0
3.0
2.0
2.0
1.0
15.0 18.5 15.0
12.0 12.5 12.0
8’
2.5
3.0
3.0
2.5
2.5
2.5
2.0
1.5
0.5
11.5 14.0 11.5
9.0
0.0
9.0
Distance
From
Ceiling
22”
60º
18”
27”
6” 12” 18” 24” 30” 36” 42” 48”
Distance to Side of Unit
38"
10'
5' - 6"
48 fc
47 fc
40"
60º
Track Dist. From Wall
Footcandles on Wall From Single Unit
Footcandles on Wall from Multiple Units†
Track Dist. From Wall
Footcandles on Wall From Single Unit
Footcandles on Wall from Multiple Units†
Track Dist. From Wall
Footcandles on Wall From Single Unit
Footcandles on Wall from Multiple Units†
* At recommended track distance from wall for corresponding ceiling height,
wall washer will provide maximum illumination at eye level (5’- 6” above floor)
when aimed 60° from horizontal (I.E.S. recommended practice).
† Footcandles shown in table for multiple units are based on a minimum of 5
units when on 18”, 27”, or 38” centers and 3 units when on 57”, 62”, or 93”
centers.
Footcandles values are based on average room conditions.
EXAMPLE: With track located 40” from wall, on 10’ ceiling and
multiple units spaced 38” on center and aimed 60° from horizontal,
the illumination on wall 5’6” from floor will be 48 f.c. beneath
units and 47 f.c. between units.
Lighting Data