Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • E0711
Calculite
®
Evolution Incandescent Lensed Wall Washer
C6P38L
Page 2 of 2
6" Aperture PAR38 Reflector Trim
Lighting Data
EXAMPLE: With multiple 120W PAR38 WFL units located
2’ from wall and 3’ on center, the illumination on the
wall 3’ down from the ceiling is 29 f.c. beneath and
24 f.c. between fixtures.
Footcandles values are averaged and rounded off and are based on a minimum of five units. For fixture-to-wall distances, other than
those shown, use maximum of 1 to 1 spacing (distance between fixtures not more than distance to wall) for best results.
3’
2’
3’
35 f.c.
38 f.c.
Footcandles on Wall From Multiple Units - 120W PAR38 WFL
Conversion Factors:
90W PAR38 WFL: F.C. x 0.70
75W PAR38 WFL: F.C. x 0.55
60W PAR38 WFL: F.C. x 0.45
2’
3’
1’
39
39
39
32
19
32
2’
56
53
56
42
31
42
3’
49
49
49
35
38
35
4’
35
35
35
24
23
24
5’
24
25
24
17
17
17
6’
17
18
17
12
12
12
7’
13
13
13
9
9
9
8’
9
10
9
7
7
7
9’
7
7
7
5
6
5
3’
4’
1’ 13 11 13
12 7 12
2’
21
20
21
17
14
17
3’
25
24
25
20
16
20
4’
24
24
24
19
17
19
5’
20
20
20
16
15
16
6’ 16 16 16
12 12 12
7’ 12 13 12
10 10 10
8’
10
10
10
8
8
8
9’
8
8
8
6
6
6
Units 3 Feet From Wall
Units 2 Feet From Wall
5˚
5˚
25˚
25˚
45˚
45˚
Candlepower Curve
120W PAR38 WFL
Report 1043FR
Efficiency = 43.5%
Down
Wall
Distance
From
Ceiling,
Ft.
Distance
From
Ceiling,
Ft.