background image

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PLASTER 
SHIELD 

PLASTER/JOINT 
COMPOUND 

 

NOTE: Photos shown here assume the Frame-In Kit 
and ceiling are already installed.  
 
For flangeless installations, cardboard PAINT 
OVERSPRAY SHIELD, which is installed in 3” 
Evolution Frame-In-Kits, must be removed prior to 
CA3FMR installation. 

 
NOTE: The bottom surface of the Frame-In Kit should be 
flush with the top surface of the ceiling material. 
 
1. Do not remove cardboard FLANGELESS TRIM RING 
PLASTER SHIELD from flangeless trim ring. 
 
2. Prior to installation, ensure that ceiling opening is      
3-5/8” in diameter.  
 
NOTE: For maximum adhesion, a bead of construction 
adhesive can be applied to the back (ceiling) side of the 
FLANGELESS TRIM RING perforated flange. 
 
3. Insert FLANGELESS TRIM RING into ceiling opening 
and rotate clockwise, ensuring the perforated flange is 
flush to the ceiling (Fig. 1).  Blades on outside edge of 
ring should bite into ceiling and secure ring in place.   
 
NOTE: For applications where ceiling thickness is less 
than ¾”, FLANGELESS TRIM RING should fit between 
ceiling & Frame-In Kit (Fig 2).   For applications where 
ceiling thickness exceeds ¾”, FLANGELESS TRIM RING 
will not contact installed Frame-In Kit.  It is therefore 
critical that FLANGELESS TRIM RING be vertically 
aligned with the Frame-In Kit aperture.  Vertical walls of 
cardboard FLANGELESS TRIM RING PLASTER 
SHIELD should fit inside Frame-In Kit aperture and be 
used to ensure vertical alignment. 
 
 
 
 
 
 

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE 

This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.  

To assure full compliance with local codes and regulations, check with your local electrical inspector before 

installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 

Retain these instructions for maintenance reference.

INSTALLATION PROCEDURE FOR CALCULITE

®

 EVOLUTION: 

CA3FMR SERIES FLANGELESS TRIM RING FOR FLANGELESS TRIMS

INSTRUCTION SHEET NO.

IS: CA3FMR

A1104 

Page 1 of 2

 

COMPANY

 

631 Airport Road, Fall River, MA 02720 

 

Fig. 1 

CEILING

INSTALL RING IN
THIS DIRECTION

FLANGELESS TRIM 
RING PERFORATED 
FLANGE 

Fig. 2

FRAME-IN KIT 

CEILING 

CA3FMR FLANGELESS
TRIM RING 

 CEILING 
OPENING

VERTICAL

WALLS

3-5/8” 
OPENING

Reviews: