IS:C4P20MH
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTALLATION INSTRUCTIONS FOR 4", 6", AND 7" RECESSED
EVOLUTION H.I.D. DOWNLIGHT TRIMS.
INSTRUCTION SHEET NO.
B0904
Page 1 of 2
A
COMPANY
631 Airport Road, Fall River, MA 02720
CAUTION: (RISK OF FIRE) DO NOT INSTALL INSULATION ABOVE NOR WITHIN 3 INCHES (76mm) OF ANY
PART OF THE LUMINAIRE (LIGHTING FIXTURE)
CAUTION: USE ONLY ROUGH-IN SECTIONS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURERS’ ROUGH-IN KITS
WILL VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
PAR-type Open
Downlights,
1-Piece Construction
ED17 Horizontal Lamp
1-piece Construction
LAMPHOLDER
(supplied with frame)
LAMPHOLDER
SPRING
(supplied with frame)
REFLECTOR NECK
Fig. 1
Installing Lampholder onto Reflector (Fig. 1)
1.
Bring LAMPHOLDER through frame opening into workspace.
2.
Snap LAMPHOLDER SPRING into two slots on REFLECTOR NECK.
3.
Check to make sure that both sides of LAMPHOLDER SPRING are fully engaged into slots.
4.
Reflector trim is now ready for installation into ceiling.
Installing Reflector into Frame (Fig. 2)
1.
Install LAMPHOLDER onto REFLECTOR NECK.
2.
Feed assembled REFLECTOR into frame opening by aligning as shown, and pushing up on FLANGE until it is fully installed into
frame opening.
Re-lamping
1.
To re-lamp one-piece units, simply unscrew the old lamp and replace with a new one. There is no need to remove trim from ceiling.
2.
For two-piece constructions, remove CONE by pulling out of trim assembly, re-lamp, and then replace CONE.
3.
See trim labeling for correct lamp info. Follow lamp manufacturer's directions for proper care and handling of lamp.
PAR-type Open
Downlights,
2-Piece Construction
TRIM
RETENTION
SPRING
Fig. 2
CONE