Welcome
Outlet
1 (844) LIGHTCLOUD
or 1 (844) 544-4825
WE’RE HERE TO HELP:
Page 1: ...Welcome Outlet 1 844 LIGHTCLOUD or 1 844 544 4825 WE RE HERE TO HELP ...
Page 2: ...er resistant duplex receptacle that delivers local and remote plug load control and power monitoring Hello Product Features Wireless Control Configuration Zone Switching Dual Power Monitoring Tamper Resistant TR CurrentLimitingto20A ...
Page 3: ...RAW 20A LOAD SWITCHING CAPACITY 2500W Resistive 1500W Tungsten 600W Electrical Ballast 1HP Motor OPERATING TEMPERATURE 0ºC to 40ºC DIMENSIONS Outlet 1 73 W x 4 1 H x 1 6 D Faceplate 2 94 W x 4 69 H x 0 06 D Faceplace Bracket 2 8 W x 4 55 H x 0 13 D TERMINAL 14 12 AWG Copper Wires Only WIRELESS RANGE Line of Sight 1000 Obstructions 100 Specifications ...
Page 4: ... copper wire Do not operate with the faceplate removed This product should only be installed by a qualified electrician and in compliance with local and national electrical codes This product should only be installed in a UL approved single gang wall box enclosure Indoor use only Configuration To configure the Outlet use the Lightcloud web application or call RAB ...
Page 5: ...e of sight between two Lightcloud devices they can be placed up to 1000 feet apart If the two devices are separated by ordinary drywall construction try to keep them within 100 feet of each other Brick concrete and steel construction may require additional AC powered Lightcloud devices to go around the obstruction See the Deployment section of your Gateway for more information Setup Installation O...
Page 6: ...up Installation cont d 2 Install the Lightcloud Outlet 2a Connect the Line Neutral and Ground to screw terminals 2b Use the two 6 32 1 2 Phillips round head screws to secure the Outlet to the junction box ...
Page 7: ... Installation cont d 2 Install the Lightcloud Outlet 2c Use the two 6 32 5 16 Phillips flat head screws provided to secure the faceplate bracket to the Outlet 2d Snap the faceplate onto the faceplate bracket ...
Page 8: ... receptacle on off Network Indicator Solid Green Connected to a Lightcloud network Blinking Red Not connected to a Lightcloud network SIGNAL STRENGTH INDICATOR Indicates strength of the connection to the next Lightcloud Device Note The network and signal strength indicators are illuminated for 10 minutes following intial power on Pressing the Device button will illuminate the newtork and signal st...
Page 9: ...g red 5 Add Outlet to Network Call RAB at 1 844 LIGHTCLOUD 6 Confirm Device Connectivity Confirm network indicator LED is solid green Install the LC Installer Application LC Installer is available for iOS and Android Scan Install Lightcloud Devices Send to RAB Once all of the devices have been added and organized submit the information for commissioning Device Table Two Device Tables are provided ...
Page 10: ...hvale NJ 07647 Custom manufactured in China 1 844 LIGHTCLOUD 1 844 544 4825 support lightcloud com Lightcloud is a commercial wireless lighting control system It s powerful and flexible yet easy to use and install Learn more at lightcloud com ...
Page 11: ...r in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment in...