LED STRING LIGHT
INSTALLATION AND USERS GUIDE
PRIOR TO INSTALLATION, PLEASE READ THE ENTIRE INSTALLATION INSTRUCTIONS
ANTES DE LA INSTALACIÓN, LEA TODAS LAS INSTRUCCIONES DE INSTALACIÓN
AVANT L’INSTALLATION, VEUILLEZ LIRE TOUTES LES INSTRUCTIONS D’INSTALLATION.
CAUTION / PRECAUCIÓN / MISE EN GARDE
SUITABLE FOR USE IN DRY, DAMP OR WET LOCATIONS.
APTO PARA USO EN UBICACIONES SECAS O HUMEDAS O MOJADAS.
CONVIENT POUR UNE UTILISATION DANS LES ENDROITS SECS OU HUMIDES.
NOT FOR EMERGENCY LIGHTING.
NO PARA ILUMINACIÓN DE EMERGENCIA.
PAS POUR ÉCLAIRAGE D'URGENCE.
NOT FOR USE IN ENVIRONMENTS WHERE EXPLOSIVE OR CORROSIVE GASES ARE PRESENT.
NO PARA USO EN ENTORNOS EN LOS QUE ESTÁN PRESENTES GASES EXPLOSIVOS O CORROSIVOS.
NE PAS UTILISER DANS LES ENVIRONNEMENTS OU DES GAZ EXPLOSIFS OU CORROSIFS SONT PRÉSENTS.
THESE LIGHTS ARE COVERED BY A 3 YEAR WARRANTY.
THIS WARRANTY DOES NOT COVER PHYSICAL DAMAGE OR IMPROPER OPERATION.
LAS LÁMPARAS VIENEN CON UNA GARANTÍA DE 3 AÑOS CONTRA DEFECTOS DE FABRICACIÓN.
ESTA GARANTÍA NO CUBRE DAÑOS FÍSICOS NI OPERACIONES INADECUADAS.
LES LAMPES ONT UNE GARANTIE DE 3 ANS CONTRE LES DÉFAUTS DE FABRICATION.
CETTE GARANTIE NE COUVRE PAS LES DOMMAGES PHYSIQUES OU LA MAUVAISE APPLICATION.
LED-9003-50K-5PK
MODEL
MODELO
MODÈLE
INPUT VOLTAGE
VOLTAJE DE ENTRADA
TENSION D'ENTRÉE
POWER
ENERGÍA
PUISSANCE
LENGTH
LONGITUD
LONGEUR
ENVIRONMENT
AMBIENTE
ENDROIT
MAXIMUM NUMBER CONNECTED
NÚMERO MÁXIMO CONECTADO
NOMBRE MAXIMUM CONNECTÉ
LED-9003-50K-5PK
120VAC
40W
50 FEET
DRY, DAMP OR WET
LOCATION
10 STRINGS TOTAL
INSTALLATION REQUIREMENTS
INSTALLATION INSTRUCTIONS
1.) Make sure the power supply provides 120 VAC and has GFCI protection.
2.) Position the lights where desired. If attaching to an overhead pipe or support, please
ensure that it has adequate strength to support the lights. Use a strong cable tie,
chain or wire to securely fasten the light to the overhead support.
After mounting the lights, please ensure that:
• Lights are clear of any flammable materials.
• Do not connect more than 10 light strings together. Do not connect other loads to light string.
• Lights and cable are clear of personnel or equipment that may cause damage or injury.
• Do not use in environments where explosive or corrosive gases are present.
• Do not use if damaged or malfunctioning.
3.) When all lights are securely mounted, plug in the power cable to confirm that lights are operating correctly.
Note: Each light string is equipped with a fuse in the plug head. If the light string is overloaded, the fuse will blow and the
light string will not work. Unplug the light strings, check for damage or overload and insert a new fuse. Only use a fuse
Rated for 125V, 8Amp.