INSTALLATION & SERVICE MANUAL – FLEXSTEP V2– UK VERSION
1.7
Liftup A/S
Hagensvej 21| DK-9530 Støvring | Denmark |
T:
+45 96 86 30 20 |
M:
[email protected] | www.liftup.dk | CVR DK-1015 3964
58
9.2
Connecting the wires
Left hand side
1 Pull flat wire and blue wires out
through upper step shaft and connect to
IR Safety TX board (103009).
2 Pull black wire from secondary slave
actuator in through upper step shaft for
connection to control board (102352).
3 Mount wires to girders with cable
binders.
Right hand side
1 Pull flat wire out through upper step
shaft and connect to IR Safety RX board
(103008).
2 Pull black wire from primary slave
actuator and grey wire from control panel
in through upper step shaft for connection
to control board (102352).
3 Mount wires to girders with cable
binders
Pull the wires from the actuators up behind the Control Board and reconnect the
wires to the connectors as illustrated below:
Wires for Actuator (Connector X4 )
1. Black (slave = H2)
2. Brown (slave = H2)
3. Red (slave = H2)
4. Black (master = H1)
5. Brown (master = H1)
6. Red (master = H1)
Mount connectors from actuator wires to
control board (102352)
1 2 3 4 5 6