Step 7:

 

Disconnect the power supply before 

proceeding with Step 7.

 Run 120V 60Hz house wiring 

(with ground) from wall switches to fan location. 
Remove junction box cover and, using wire nuts, 
connect house wires to unit wires. Refer to Wiring 
Diagram on page 4.  

Note: 

12AWG is the minimum conductor to be used 

for branch-circuit wiring. 

CAUTION:

 If you electrical wires do not match the 

colors listed, you must determine what each house 
wire represents before connecting. You may need to 
consult an electrical contractor to determine safely. 

 

 

Wire Nuts instructions: 
WARNING: 

Wiring must comply with all applicable 

electrical codes. Turn OFF power before removing or 
installing connectors. COPPER TO COPPER ONLY. Do 
not use aluminum wire.

 

CAUTION: 

Accessory part (Wire nuts) should meet 

installation instructions below. 

NOTE: 

The connector in reusable on solid wires of the 

 same wire gage or smaller. Do not reuse the nut on 
stranded wires. 
 

 

Strip wires 3/8”-1/2” 

 

Grip the wire firmly and push the stripped end of  
the wire into the open port of the nut. Use only 
one conductor per port. 

 

Verify the stripped end of the wires is fully inserted 

to the back of the nut. 

NOTE: 

 Important wire information. Maximum 

temperature rating 105

(221

).600 volts maximum 

for building wire and 1000 volts maximum for 
building wire and 1000 volts maximum in signs and 
lighting fixtures. The acceptable wire range includes: 
solid 12-18 AWG. 

 

Green wires

 are ground wires. House ground may 

be green or bare. 

 

White wires

 are neutral. They carry power back to 

the service panel.  

 

Black wires

 are hot. They carry power from the 

panel to the fan.  

 

Step 8: 

Install a circular 4 in. duct and secure it with 

duct tape or clamps. 

 

Finish ceiling work. (Ceiling hole should be aligned 
with edge of fan housing.) 
 

Step 9: 

Then thread 

Light harness plug

 onto screw in 

fan housing as shown.  

 

Step 10: 

Connect the Light harness plug

 into the white 

Summary of Contents for DSQR70BNOR

Page 1: ...tial series bathroom fan uses state of the art technology providing superior long life performance for your room ventilation needs Table of Contents GENERAL SAFETY INFORMATION AND WARNINGS 1 LIST OF INCLUDED PARTS AND ACCESSORIES 2 LIST OF ADDITIONAL TOOLS SUPPLIES REQUIRED FOR INSTALLATION 3 PLANNING INSTALLATION 3 SPECIFICATIONS 4 DIMENSIONS 4 WIRING DIAGRAM 4 FAN HOUSING INSTALLATION DIRECT JOI...

Page 2: ...ng the life of the motor 6 Always disconnect the power supply prior to servicing the fan motor or junction box 7 Do not bend or kink the power wires 8 This ventilating fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit 9 Do not use to exhaust hazardous or explosive vapors 10 Do not install in a cooking area 11 Do not install in a ceiling with insulation gre...

Page 3: ...ng or replacement parts Part Part Name Photo Qty Part Part Name Photo Qty 1 Bath fan housing 1 5 Grille and shade mounting hardware Finial cap and Finial nut 2 2 Bath fan glass globe 1 6 3 Light harness plug 1 7 4 Long wood screw M4 30 4 8 1 lock nut For Customer Support please email support strategicretailsolutions com or call 888 930 8528 Please provide the bath fan model number found on the fro...

Page 4: ... after the finished ceiling is in place Use the dimensions provided in this manual to determine the required hole size for the ceiling The ducting from this fan to the outside of the building has a strong effect on the airflow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than specified in thi...

Page 5: ...ension W x L Housing Dimension D Grille Dimension 6 1 5 in 15 8 cm in x 8 1 2 in 22 cm x 21 5cm 83 10 in x 8 in 21cmx 20 5cm 5 4 5 in 14 8 cm 12in 30 5cmx cm WIRING DIAGRAM For Customer Support please email support strategicretailsolutions com or call 888 930 8528 Please provide the bath fan model number found on the front of this manual when contacting Customer Support 30 5 12in x 8 5 3 ...

Page 6: ...ousing in an existing building requires access attic or crawl space in the planned installation location above the existing ductwork and wiring Inspect existing ductwork and wiring before proceeding with installation Step 1 Turn off power source Review all safety precautions Step 2 Remove the existing fan Step 3 Measure the opening to ensure it is large enough to accommodate the new fan housing 8 ...

Page 7: ...wire CAUTION Accessory part Wire nuts should meet installation instructions below NOTE The connector in reusable on solid wires of the same wire gage or smaller Do not reuse the nut on stranded wires Strip wires 3 8 1 2 Grip the wire firmly and push the stripped end of the wire into the open port of the nut Use only one conductor per port Verify the stripped end of the wires is fully inserted to t...

Page 8: ...ath fan model number found on the front of this manual when contacting Customer Support receptacle in the fan housing Step 11 Install two lamp base E12 bulbs Step 12 Place bath fan shade onto the Light harness plug Secure bath fan shade to rod with finial cap and finial nut Turn on electricity at breaker box after finishing installation ...

Page 9: ...e motor Do not immerse resin parts in water over 140 1 Carefully unscrew finial cap and finial nut to remove from the bath fan grille 2 Clean glass shade with a soft towel or paper towels and glass cleaner avoid harsh detergent in a sink 3 Clean inside of unit with a vacuum cleaner Do not use liquid cleaner as the motor should not come in contact with any liquid 4 Dry the bath fan shade and grille...

Page 10: ...plied warranty the above exclusions and limitations may not apply This warranty gives you specific rights and you may have other rights that vary from state to state THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE PARTS ONLY AND ANY COSTS RELATED TO SAME SHALL NOT EXCEED THE USER S COST OF THE PRODUCT MANUFACTURER ALSO RETAINS THE OPTION OF REFUNDING PURCHASE PRICE AS FULL SETTLEMEN...

Reviews: