![Life Racing D5 System Manual Download Page 26](http://html.mh-extra.com/html/life-racing/d5/d5_system-manual_1908975026.webp)
Configuration
© Life Racing Ltd
Page 25 of 45
4.8
Alarms
Alarms are set in LifeDash via the ‘Alarms’ tab. To add an alarm press Add Alarm. Alarms are
typed in the format:
ALARM TYPE(“Display text”, On Conditions, Off Conditions)
Alarm types can either be;
‘MESSAGE’ which is dismissible and displayed in green (Off Conditions Omitted).
‘WARNING’ which is dismissible, displayed in yellow and activates the yellow LED.
‘ALARM’ which is not dismissible, displayed in red and activates the red LED.
The Display text is the message that will appear when the alarm is triggered.
The On Conditions are the conditions that must be met for the alarm to trigger.
The Off Conditions are the conditions that must be met to switch off an alarm after it has
triggered.
Alarms are case sensitive and must use abbreviated names in expressions.
Units used in alarm expressions are the same as displayed units.
To open the Alarm Editor either press OK (space) or double click the highlighted alarm. If the
alarm is incompatible, the Editor will not allow it to be added. It will instead display an error
hint above where the error has occurred.
In addition to warnings and messages, an alarm can force a certain page to be displayed with
the following command: