Configuration
© Life Racing Ltd
Page 19 of 45
Gauge Values
Default Val:
Default value, value shown on gauge if no information is received.
Min Val:
Minimum value, lowest allowed value and scale limit.
Max Val:
Maximum value, highest allowed value and scale limit.
*Note*
Physical and CAN inputs will be clipped at these min/max values. Built in items (D5.1.X) are
unaffected.
Gauge scales are defaulted to these values but can be altered in ‘Edit Mode’.
Alarm Values
Alarm low:
If enabled, when item value is lower than this, gauge changes colour.
Alarm high:
If enabled, when item value is higher than this, gauge changes colour.
*Note*
The colour that each gauge changes to in alarm conditions can be individually altered in ‘Edit
Mode.’ By default, alarms appear red.
Enumeration
Display text depending on numerical value.
User Icon
An icon can be displayed with the selected item on the dash display. If the box is not checked
the default icon will be displayed (may be blank). To apply a different icon, tick the box and
select the new icon from the list. More icons will be added with future software updates.