Model No.

A-Depth
in. (mm)

B-Width

in. (mm)

C-Height

in. (mm)

Weight

lbs. (kg)

Voltage

(60 Hz)

Voltage

(50 Hz)

PS018A

36 (914)

40 (1016)

25.25 (641))

394 (178)

208/230, 1-phase

200/230, 1-phase

PS024A

36 (914)

40 (1016)

25.25 (641)

404 (183)

208/230, 1-phase

200/230, 1-phase

PS036A

36 (914)

48 (1219)

32.5 (825)

515 (233)

460, 3-phase

208/230, 1- or 3-phase

400, 3-phase

200/230, 1- or 3-phase

PS048A

36 (914)

53 (1346)

38.5 (978)

592 (268)

460, 3-phase

208/230, 3-phase

400, 3-phase

200/230, 1- or 3-phase

PS060A

36 (914)

53 (1346)

38.5 (978)

642 (291)

460, 3-phase

208/230, 3-phase

400, 3-phase

200/230, 1- or 3-phase

ACCESS, AND AIR FLOW.

FOR COMPONENT REMOVAL,

RECOMMENDED CLEARANCE

INDICATE A

SHADED AREAS

H

H

I

I

(25mm)

1" MAX.

(25mm)

1" MAX.

(914mm)

36"

(914mm)

36"

UNIT DIMENSIONAL DATA

OUT

AIRFLOW

B

IN

AIRFLOW

C*

D

A

1" NPT

(914mm)

36"

(51mm)

2"

(457mm)

18"

ACCESS, AND AIR FLOW.

FOR COMPONENT REMOVAL,

RECOMMENDED CLEARANCE

INDICATE A

SHADED AREAS

PRESSURE GAUGES

OPTIONAL REFRIGERANT

UNIT DIMENSIONAL DATA

Standard Features

• Indoor/outdoor cabinet
• Hermetic compressor
• Refrigerant dehydrator
• Expansion valve
• Refrigerant receiver
• Stainless steel fluid reservoir expansion tank
• Pressure relief valve
• Hot gas bypass valve capacity control

Optional Features

• Refrigerant gauges and reservoir heater
• Stainless steel pump

Accessories

• Emergency water bypass
• Enviro-source emergency bypass
• Water level control and alarm system
• Fluid  pressure  gauge
• Check  valve
• Dial thermometer
• Relief valve
• Circuit setter
• Ball valve
• High temperature thermostat
• Low flow switch
• Liebert RCM8 monitor