AC Power
For 

Business-Critical Continuity™

Liebert GXT2-6000RTL630

User Manual - 208 / 240 VAC

Summary of Contents for GXT2-6000RTL630

Page 1: ...AC Power For Business Critical Continuity Liebert GXT2 6000RTL630 User Manual 208 240 VAC...

Page 2: ......

Page 3: ...5 1 2 Rack Mount UPS Installation 12 5 1 3 Installing the Adjustable Rack Mount Kit Sold Separately 12 5 2 Install the Internal Batteries 14 5 3 Connect the Internal Batteries Using the External Conne...

Page 4: ...TROUBLESHOOTING 31 12 0 1 Auto Learning Battery Run Times 35 13 0 SPECIFICATIONS 36 FIGURES Figure 1 GXT2 6000RTL630 front view 7 Figure 2 GXT2 6000RTL630 rear view 8 Figure 3 Internal battery pack wi...

Page 5: ...sive substances This UPS contains no user serviceable parts except the internal battery pack The Off Bypass push button does not electrically isolate internal parts Under no circumstances attempt to g...

Page 6: ...e is harmful to skin and eyes It is toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries...

Page 7: ...ctions AC input AC output Requests the user to consult the manual Indicates the unit contains a valve regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC v...

Page 8: ...nuously conditions and regu lates its output voltage whether utility power is present or not It supplies connected equipment with clean sinewave power Sensitive electronic equipment operates best from...

Page 9: ...e amount of distortion reflected on the utility is reduced This results in cleaner power being available to other devices in the building not being protected by the GXT2 6000RTL630 2 3 Inverter In nor...

Page 10: ...external battery cabinets are available to extend battery run times 2 7 Dynamic Bypass The GXT2 6000RTL630 provides an alternate path for utility power to the connected load in the unlikely event of a...

Page 11: ...eries to lighten the UPS for easier installation The internal batteries may be installed after the cabinet has been placed in its final floor or rack position The Power Distribution box is shipped sep...

Page 12: ...OUTPUT BREAKER 20A 240V T ON ON INPPUT OUTPUT ONLY CB DOES NOT CONNECT BYPASS POWER TO MANUAL BYPASS SWITCH BREAKER 30A ON OFF OFF OFF UPS UTILITY COMMUNICATION PORT SEE MANUAL FOR CONNECTIONS OFF RE...

Page 13: ...andard box for custom installations Figure 4 Optional power distribution PD L630 OUTPUT BREAKER 20A 240V T OUTPUT BREAKER 20A 240V T ON ON INPPUT OUTPUT ONLY CB DOES NOT CONNECT BYPASS POWER TO MANUAL...

Page 14: ...and screws 2 each Support base 2 Mounting hardware Configuration program CD DB 9 port cover GXT2U Configuration Program www liebert com For use with Liebert GXT2U model UPS systems Version 1 6 For Win...

Page 15: ...ermine the type of installation and follow the appropriate instructions in either 5 1 1 Tower UPS Installation or 5 1 2 Rack Mount UPS Installation 5 1 1 Tower UPS Installation When using the GXT2 600...

Page 16: ...ing brackets Part RMKIT18 32 feature retaining latches to prevent users from inadvertently sliding the UPS or battery cabinet out of the rack To install the rack mount brackets 1 Unpack two 2 rack mou...

Page 17: ...eck alignment of bracket assemblies and TIGHTEN ALL SCREWS FROM Steps 2 and 3 5 Prepare the UPS or battery cabinet the equipment for rack mounting by following instructions in the equipment s user man...

Page 18: ...flange of the front members you can use the four 4 extra M5 screws provided in the kit to secure the equipment Otherwise the equipment should be secured to the front of the rack with four 4 customer s...

Page 19: ...ed position using two screws The picture on the left shows the connector in the open position as shipped When the UPS is installed remove the two screws to release the connector Plug the connector int...

Page 20: ...L630 power distribution box OUTPUT BREAKER 20A 240V T OUTPUT BREAKER 20A 240V T ON ON INPPUT OUTPUT ONLY CB DOES NOT CONNECT BYPASS POWER TO MANUAL BYPASS SWITCH BREAKER 30A ON OFF OFF OFF UPS UTILITY...

Page 21: ...cuit breaker on the rear fixed panel of the UPS disconnect all power between the main cabinet and the distribution box Models equipped with a manual bypass switch pass bypass power directly to the byp...

Page 22: ...attery cabinet 5 Connect the supplied external battery cabinet cable to the rear of the external battery cabinet then to the rear of the UPS 6 The UPS is now equipped with additional backup battery ru...

Page 23: ...ker located on the distribution box The green AC Input indicator should illuminate on the UPS front panel 10 Press the On button for 1 second The BYPASS lamp will light for several seconds before the...

Page 24: ...50 or 60 Hz Set the Low Battery Warning alarm time from 2 to 30 minutes Enable Disable the Auto Battery test Set the Auto Battery test to 7 14 21 or 28 days Specify the number of external battery cab...

Page 25: ...LEDs illuminate allow the UPS to recharge the batteries for 24 hours After 24 hours retest the batteries After the batteries have been retested if only three of the five Battery LEDs illuminate conta...

Page 26: ...MultiLink 3 x software and can remotely initiate the battery test 8 5 Fault Indicator LED Red The Fault indicator LED is illuminated if the UPS has detected a problem Also one or more of the battery l...

Page 27: ...el indicator represents a 20 capac ity level As capacity decreases fewer indicators remain illumi nated Refer to 12 0 Troubleshooting For approximate battery run times refer to Table 5 These times are...

Page 28: ...gnal will start a 2 minute shutdown timer The timer cannot be stopped After 2 minutes the UPS will shut down 4 If utility power returns during the 2 minute timer countdown the shutdown timer will cont...

Page 29: ...license Kits visit our Web site www liebert com or contact your local dealer or Liebert representative Several option cards are available for use in the Intellislot port of the GXT2 6000RTL630 The Int...

Page 30: ...ment to comply with national and local wiring codes and regulations REPO switch connection diagram CAUTION To maintain safety SELV barriers and electromagnetic compatibility signal cables should be se...

Page 31: ...length of time it is essential to plug the UPS in for at least 24 hours every four to six months to ensure full recharge of the batteries Failure to recharge the batteries peri odically will result in...

Page 32: ...way 8 Reconnect the electrical connections for each battery pack 9 Install the battery retaining brackets using the Phillips removed earlier 10 Install the battery access panel and tighten the captive...

Page 33: ...t breaker on the rear of the UPS 7 Remove the distribution box from the UPS a Loosen all three captive screws until the box releases b Pull box away from the UPS and set the box aside on a padded surf...

Page 34: ...ainst the UPS and tighten the captive screws Do not overtighten 6 If the utility branch circuit breaker and load is off turn the branch breaker on now 7 Turn on the output circuit breaker on the rear...

Page 35: ...Please have the UPS model number and serial number available at the time of your inquiry Table 2 Indicator meanings LED status Diagnosis Audible alarm All LEDs On bypass due to output overload beep e...

Page 36: ...ive or the Liebert Worldwide Support Group Fault and Bypass indicator LEDs and diagnostic LED B are illuminated UPS internal DC bus overvoltage UPS requires service Contact your local dealer Liebert r...

Page 37: ...utility failure One short beep every 10 seconds more than 2 minutes of run time remaining Low Battery Two short beeps every 5 seconds less than 2 minutes of run time remaining Output Overload Bypass...

Page 38: ...s 10 94 20 46 30 29 40 21 50 17 60 13 70 11 80 9 90 8 100 7 Internal Battery 1 External Battery Cabinet minutes 10 222 20 124 30 81 40 60 50 49 60 39 70 33 80 28 90 24 100 21 Internal Battery 2 Extern...

Page 39: ...s The UPS will update the anticipated run time calculation only under certain conditions The UPS must have a steady load that is greater than 20 The UPS must be at 100 charge at the start of a battery...

Page 40: ...Nominal Waveform Sinewave Main Mode Overload 200 for 96 milliseconds 131 199 for 2 seconds 112 129 for 10 seconds with transfer to bypass Bypass Protection Limits Disable Bypass operation If input vo...

Page 41: ...W 28 12FT Electrical Characteristics Back up Time See Table 5 Battery run times Recharge Time 3 hrs to 90 capacity after full discharge into 100 load Table 8 Output distribution specifications Model N...

Page 42: ...tery Parameters Type Valve regulated non spillable flame retardant lead acid Qty x V 20 x 12V Battery Manufacturer Part Yuasa REW 45 12 Backup Time See Table 5 Battery run times Environmental Operatin...

Page 43: ......

Page 44: ...bert Corporation All names referred to are trademarks or registered trademarks of their respective owners Technical Support Service Web Site www liebert com Monitoring 800 222 5877 monitoring emersonn...