17
Note: the above position of the decimal point is determined according to that
in the instrument.
3.
Continuous output B format
Continuous output agreement B format:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
HEAD1 , HEAD2 , DATA UNIT
CR/LF
HEAD1
:
OL Upper overload or lower overload, or no zero clearing in
startup;
ST the scale is in stable state;
US the scale is in unstable state;
HEAD2
:
GS gross weight
;
NT net weight
;
DATA
:
instrument display data
;
UNIT
:
kg or lb
;
CR/LF
:
new line.
Example 1
:
in stale state, gross weight is 18.000kg. sp = space.
S T , G S , sp sp 1 8 . 0 0 0 k g
0
d
0a
Example 2
:
in unstable state, net weight is -0.200kg. sp = space.
U S , N T , - sp sp 0 . 2 0 0 k g
0
d
0a
Appendix 2. Printing Format Specification
F2.1 = 0, 1, 4, 6
,
print current resetting, press
『
』
.
F2.1 = 1 weight maintenance function:
REPORT
------------------------
Gross 0.200kg
Tare 0.000kg
Net 0.200kg