Note: the above position of the decimal point is determined according to that 

in the instrument. 

3.

 

Continuous output B format   

                Continuous output agreement B format:

 

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18 

HEAD1 , HEAD2 ,                            DATA                                        UNIT       

CR/LF 

HEAD1

OL      Upper overload or lower overload, or no zero clearing in 

startup;   

ST      the scale is in stable state; 

US      the scale is in unstable state; 

HEAD2

GS      gross weight

 

NT      net weight

 

DATA

  instrument display data

 

UNIT

    kg or lb

 

CR/LF

  new line. 

Example 1

  in stale state, gross weight is 18.000kg. sp = space.

 

S  T  ,  G  S  ,  sp  sp  1  8  .  0  0  0  k  g 

0

0a 

Example 2

  in unstable state, net weight is -0.200kg. sp = space.   

U  S  ,  N  T  ,  -  sp  sp  0  .  2  0  0  k  g 

0

0a 

Appendix 2. Printing Format Specification   

F2.1 = 0, 1, 4, 6

print current resetting, press

Print

.   

 

 

 

 

 

F2.1 = 1 weight maintenance function: 

        REPORT                 
------------------------ 
Gross        0.200kg 
Tare          0.000kg 
Net            0.200kg

 

Summary of Contents for LUW2001/LBW

Page 1: ...User manual for LUW2001 LBW...

Page 2: ...epair controller Warning Please keep good grounding of controller Warning In electrical connection of controller please cut off the power supply in advance Wait for 30 seconds between power on of the...

Page 3: ...METER SETTING 6 SETTING ENTRY 6 PARAMETER SETTING OF F1 SCALE 6 F2 APPLICATION FUNCTION SETTING 8 F3 ENERGY SAVING PARAMETER SETTING 9 F4 SERIAL PORT SETTING 9 F5 MAINTENANCE AND SERVICE 10 VI FUNCTIO...

Page 4: ...t 0 1A Frequency 50 60Hz 2 RS232 ports Operating temperature 10 40 relative humidity is below 85 Storage temperature 20 60 relative humidity is below 85 Conforming to standard GB T 7724 1999 II Main F...

Page 5: ...he lamp is off Zero center indication The lamp is on when the absolute value of weight on the scale is less than 0 2d otherwise the lamp is off Net Identification of gorses weight and net weight The l...

Page 6: ...rn to the last m en u Accumulation key Short key F2 1 4 include display weight in accumulation value Long key F2 1 3 select scale to sample target weight F2 1 4 accumulate weight of scale display F2 1...

Page 7: ...Hold button on the operating panel in the state of normal weighing If F1 14 0 you can set all the parameters within F1 F5 If F1 14 1 you can only set all parameters within F2 F5 If F1 14 1 and you ne...

Page 8: ...ighing platform to ensure that 10 of full scale value weight of weights full scale value and then press the Print key to start the next step Entering the same weight value as that of the loaded weight...

Page 9: ...2 Application Function Setting F2 1 Function Selection Selectable Parameters 0 Close the application functions default value 1 Weight keeping function 2 Percentage display function 3 Weight checking a...

Page 10: ...ers 0 250 minutes default value 150 minutes If set to be 0 this function shall not be allowed F3 3 Display Brightness Control Selectable Parameters 0 low light level 1 middle light level default value...

Page 11: ...99 default value HoLi01 F4 2 Parameter Setting of UART1 Printing Interface F4 2 1 Whether to connect the printer Selectable Parameters 0 not connected to the miniprinter default 1 connected to the min...

Page 12: ...ld indication lamp is on Only when weight setting value F2 2 is displayed weight maintenance operation is effective Otherwise it will return to weighing state after invalid operation information is sh...

Page 13: ...Total on operation panel if the display shows progress bar it indicates that the current display weight is included accumulated value and then it returns to normal weighing state If the display shows...

Page 14: ...2 1 6 Operation method In normal weighing state place the animal on the weighing platform and its weight must be threshold value set in F2 2 Press Total instrument will collect data sampling After sam...

Page 15: ...struments of the factory 7 The calibration input weight is too small Input 10 weight of full range 8 The weight in calibration is too light Load 10 weight of full range 9 The scale is dynamic in scale...

Page 16: ...s word A B C 3 Display weight possibly gross weight or net weight 6 digits without symbol or decimal point 4 Tare weight 6 digits without symbol or decimal point 5 CR ASCII carriage return ODH 6 CKS o...

Page 17: ...1 Constant 0 Bit 2 Constant 0 Bit 3 Constant 0 Bit 4 Constant 1 Bit 5 Constant 1 Bit 6 Constant 0 Bit 7 Constant 0 check bit 2 Continuous output A format The data transmitted by continuous output prot...

Page 18: ...the scale is in stable state US the scale is in unstable state HEAD2 GS gross weight NT net weight DATA instrument display data UNIT kg or lb CR LF new line Example 1 in stale state gross weight is 18...

Page 19: ...weight Print details and total weight Only print total weight F2 1 5 counting scale press Print REPORT Gross 1 980kg State Less REPORT Gross 2 000kg State OK REPORT Gross 2 020kg State Over REPORT Gr...

Reviews: