Liberty Pumps, Inc. warrants that pumps of its Engineered Product line are free from all factory defects in material and workmanship for a
period of 18 months from the date of installation or 24 months from the date of manufacture, whichever occurs first, and provided that
such products are used in compliance with their intended applications as set forth in the Liberty Engineered Products specifications and
technical manuals. The date of installation shall be determined by a completed pump start-up report and warranty registration form.
A pump startup report, filled out by a qualified installer, is required for warranty to take effect. The report must be submitted within 30
days from the installation date and submitted through the Liberty Pumps website. During the warranty period, the manufacturer's
obligation, and at its discretion, shall be limited to the repair or replacement of any parts found by the manufacturer to be defective,
provided the product is returned freight prepaid to the manufacturer or its authorized service center, and provided that none of the
following warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the product has not been properly installed or maintained in accordance with
the printed instructions provided; if it has been disassembled, modified, abused or tampered with; if the pump discharge has been
reduced in size; if the pump has been used in water temperatures above those shown in the specifications; if the thermal overload(s) and
seal moisture probe(s) have not been properly connected (where equipped); if the pump has been used in water containing sand, lime,
cement, gravel or other abrasives; if the product has been used to pump chemicals or hydrocarbons; if the product has been moved from
its original installation location, or if the label bearing the serial and code number has been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage or expenses resulting from installation or use of its products, or for
consequential damages, including field labor costs, travel expenses, rental equipment, costs of removal, reinstallation or transportation to
and from the factory or an authorized Liberty Pumps repair facility.
There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are
limited to 18 months from the date of installation or 24 months from the manufacturing date. This Warranty contains the exclusive
remedy of the purchaser, and, where permitted, liability for consequential or incidental damages under any and all warranties are
excluded.
www.LibertyPumps.com/LEP/Warranty
Pump runs or hums but does not
pump.
Discharge line blocked or restricted.
Check the discharge line for foreign material,
including ice if the discharge line passes
through or into cold areas.
Check valve is stuck closed or installed
backward.
Remove check valve(s) and examine for freedom
of operation and proper installation.
Gate or ball valve is closed.
Open gate or ball valve.
Total head is beyond pump's capability.
Route piping to a lower level. If not possible, a
larger pump may be required. Consult Liberty
Pumps.
Obstructed impeller or volute.
Remove obstruction.
Pump is airlocked.
Turn pump off and let set for several minutes,
then restart.
Add baffle to reduce trapped air bubbles.
Capacitor failure in control panel.
Check capacitors and replace if needed.
Stuck/defective motor contactor in control
panel.
Replace motor contactor.
Pump is not seated correctly in guide rail base.
Lift pump and re-position.
Table 3. Troubleshooting Matrix (continued)
Problem
Possible Cause
Corrective Action