background image

14 | EN

Copyright © Liberty Pumps, Inc. 2022 All rights reserved.

7550000G

Wa rra nty

Liberty Engineered Products Limited Warranty

Liberty Pumps, Inc. warrants that pumps of its Engineered Product line are free from all factory defects in material and workmanship for a 

period of 18 months from the date of installation or 24 months from the date of manufacture, whichever occurs first, and provided that 

such products are used in compliance with their intended applications as set forth in the Liberty Engineered Products specifications and 

technical manuals. The date of installation shall be determined by a completed pump start-up report and warranty registration form.
A pump startup report, filled out by a qualified installer, is required for warranty to take effect. The report must be submitted within 30 

days from the installation date and submitted through the Liberty Pumps website. During the warranty period, the manufacturer's 

obligation, and at its discretion, shall be limited to the repair or replacement of any parts found by the manufacturer to be defective, 

provided the product is returned freight prepaid to the manufacturer or its authorized service center, and provided that none of the 

following warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the product has not been properly installed or maintained in accordance with 

the printed instructions provided; if it has been disassembled, modified, abused or tampered with; if the pump discharge has been 

reduced in size; if the pump has been used in water temperatures above those shown in the specifications; if the thermal overload(s) and 

seal moisture probe(s) have not been properly connected (where equipped); if the pump has been used in water containing sand, lime, 

cement, gravel or other abrasives; if the product has been used to pump chemicals or hydrocarbons; if the product has been moved from 

its original installation location, or if the label bearing the serial and code number has been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage or expenses resulting from installation or use of its products, or for 

consequential damages, including field labor costs, travel expenses, rental equipment, costs of removal, reinstallation or transportation to 

and from the factory or an authorized Liberty Pumps repair facility.

There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are 

limited to 18 months from the date of installation or 24 months from the manufacturing date. This Warranty contains the exclusive 

remedy of the purchaser, and, where permitted, liability for consequential or incidental damages under any and all warranties are 

excluded.

www.LibertyPumps.com/LEP/Warranty

Pump runs or hums but does not 

pump.

Discharge line blocked or restricted.

Check the discharge line for foreign material, 

including ice if the discharge line passes 

through or into cold areas.

Check valve is stuck closed or installed 

backward.

Remove check valve(s) and examine for freedom 

of operation and proper installation.

Gate or ball valve is closed.

Open gate or ball valve.

Total head is beyond pump's capability.

Route piping to a lower level. If not possible, a 

larger pump may be required. Consult Liberty 

Pumps.

Obstructed impeller or volute.

Remove obstruction.

Pump is airlocked.

Turn pump off and let set for several minutes, 

then restart.
Add baffle to reduce trapped air bubbles.

Capacitor failure in control panel.

Check capacitors and replace if needed.

Stuck/defective motor contactor in control 

panel.

Replace motor contactor.

Pump is not seated correctly in guide rail base.

Lift pump and re-position.

Table 3. Troubleshooting Matrix (continued)

Problem

Possible Cause

Corrective Action

Summary of Contents for LGH Series

Page 1: ... system pressures Installer manual must remain with owner or system operator maintainer Record information from pump nameplate Model Serial Control Panel Mfg Date Install Date Dealer Dealer Ph 7000 Apple Tree Avenue Bergen NY 14416 ph 1 800 543 2550 fax 1 585 494 1839 www LibertyPumps com LEP 60 Hz 7550000G LGV Series LGH Series Ordinary Location Models XLGV Series XLGH Series Approved for Hazardo...

Page 2: ...wer cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installations it shall be at least 4 ft 1 22 m above floor level Do not use this product in applications where human contact with the pumped fluid is common such as swimming pools fountains marine areas etc...

Page 3: ... careful around pump base while power is connected Make sure that the pump is either in the tank or clear from people and wires when in operation Wear adequate Personal Protective Equipment when working on pumps or piping that have been exposed to wastewater Sump and sewage pumps often handle materials that can transmit illness or disease upon contact with skin and other tissues Do not enter a pum...

Page 4: ...t trim impellers without consulting the factory Model Specifications For complete listing of models and their specifications refer to www LibertyPumps com lep About Engineering Specs Pump nameplate provides a record of specific pump information Inspection and Storage Initial Inspection The pump should be immediately inspected for damage that may have occurred in shipment 1 Visually check the pump ...

Page 5: ...onents can be purchased separately using the part numbers shown Other options such as pre wired kits are also available Control Panels in Hazardous Locations Float switches must be connected to an intrinsically safe circuit in the control panel as per the requirements of Chapter 5 of the National Electric Code For hazardous locations the control panel must be installed outside the hazardous area a...

Page 6: ... the pump will continue to operate but service should be scheduled as soon as possible The LEP Series control panels by Liberty Pumps have a seal leak detection system with a test button that monitors the integrity of the seal leak circuit and components When pressed the light should illuminate The light should go off when the test button is released If it remains on the potentiometer is set too h...

Page 7: ...K POTTING RESIN RED WHITE ORANGE RUN CAP 80 MFD 370 VAC START CAP 270 324 MFD 330 VAC SEAL LEAK POWER CORD CONTROL CABLE ORANGE RED RED WHITE WHITE GREEN GREEN BLACK BLACK THERMOSTAT M3 M2 M1 L3 L2 L1 MOTOR GRAY BROWN BROWN GREEN GRAY THERMOSTAT SEAL FAILURE PROBES POTTING RESIN FOR HAZLOC PUMPS M3 M2 M1 1 6 7 2 4 8 3 5 9 200 230V 3PH 2D 460V 3PH 1D 15HP MODELS ONLY M3 M2 M1 1 1 2 2 3 1 2 3 3 7 7 ...

Page 8: ...e 1 and Figure 2 Figure 1 Cut off Point 3 7 hp Pumps Figure 2 Cut off Point 10 15 hp Pumps Cutter and Impeller Free Movement Check Wear Personal Protective Equipment to protect hands as cutter blades have extremely sharp edges and present a serious cutting hazard Do not connect any power to pump until this check is complete Manually rotate the cutter and impeller to check that they spin freely wit...

Page 9: ... as short as possible with a minimum number of turns to minimize friction head loss Do not reduce the discharge to below the pump outlet size Larger pipe sizes may be required to eliminate friction head loss over long runs Contact Liberty Pumps or other qualified person if questions arise regarding proper pipe size and flow rates Pressure Sewer Applications A redundant check valve assembly consist...

Page 10: ...le of operation 7 Turn H O A switch es to OFF position and allow basin to fill to the override alarm control level s 8 Observe all floats in operation to verify that there is adequate clearance to the surrounds to ensure that the floats do not have the opportunity to get hung up in their travel 9 Verify alarm system response 10 Turn switch es to AUTO position pumps should start and operate togethe...

Page 11: ...ps The only allowable repairs replacements without compromising the hazardous location rating of the pump are Quick connect cords lower outer shaft seals volute and impeller components Otherwise the pump must be returned to Liberty Pumps or an authorized hazardous repair facility for electrical and motor service This will ensure the integrity of the hazardous location rating of the pump and comply...

Page 12: ...ctive float switch Replace float switch Missing or faulty curb stop swing check valve allowing system pressure to feed back through discharge piping Verify presence of a curb stop check valve or replace curb stop swing check valve assembly Pump operates with selector switch in Hand position but does not operate in Auto position Control circuits malfunctioning Check float switch level control or al...

Page 13: ...essure to feed back through discharge piping Verify presence of a curb stop check valve or replace curb stop swing check valve assembly Pump runs periodically when fixtures are not in use Check valve not installed stuck open or leaking Install check valve s remove check valve and examine for freedom of operation and proper installation Fixtures are leaking Repair fixtures as required to eliminate ...

Page 14: ... gravel or other abrasives if the product has been used to pump chemicals or hydrocarbons if the product has been moved from its original installation location or if the label bearing the serial and code number has been removed Liberty Pumps Inc shall not be liable for any loss damage or expenses resulting from installation or use of its products or for consequential damages including field labor ...