background image

1

2

Top

Side

Front

Back

3
4
5

6

7
8
9

10

11

LG QUAD 

COMBO

 UNIT

For more information about your LG QUAD Combo™ unit, please visit us online at lgmedsupply.com or call 1-888-633-7360.

QUICK REFERENCE GUIDE 

PAGE 1

The purpose of this guide is to assist you in correctly operating your LG QUAD Combo™ unit.  This 
device should only be used under the continued supervision of a healthcare professional. This guide 
is not intended to replace or substitute the LG QUAD Combo™ Instruction Manual. PLEASE READ THE 
INSTRUCTION MANUAL COMPLETELY BEFORE USING THIS DEVICE. 
Read, understand and practice 
the contraindications, warnings, cautions and operating instructions found on pages 8 – 13 on your 
instruction manual. Always follow the operating instructions prescribed by your healthcare provider.

12

13

Channel 1 output socket
Channel 2 output socket
Channel 1 intensity increase button
Channel 1 intensity decrease button
Mode (M) selection button
LCD display
Channel 2 intensity increase button
Channel 2 intensity decrease button
Parameter (S) selection button
Power on/off button
Belt clip
Battery compartment cover
AC/DC adapter receptacle

1
2
3
4
5
6
7
8
9

10
11
12
13

ELECTRODES

(4 SETS)

LEAD WIRES

(2 SETS)

INDICATION FOR USE

The TENS / IF / MIC modes are often prescribed for:

 

  Symptomatic relief of chronic pain

 

  Post traumatic pain

 

  Post surgical pain

The EMS mode is often prescribed for:

 

  Relaxation of muscle spasms

 

  Increase of blood flow circulation

 

  Prevention of disuse atrophy

 

  Muscle re-education

 

  Maintaining or increasing range of motion

 

  Immediate post-surgical stimulation of lower 

 

  leg muscles to prevent venous thrombosis

Do not use this device for undiagnosed pain 

syndromes until consulting a physician.

DEFINITIONS

TENS

Transcutaneous Electrical 

Nerve Stimulator

IF

Interferential

MIC

Microcurrent

EMS

Electrical Muscle Stimulation/ 

Neuromuscular Stimulation

Live Pain Free, Live Good Today!

LG  QUAD Combo

Use 4 electrodes when using the Interferential mode. Press 

the 

S

 button to enter and cycle through to each setting state.

SET THERAPEUTIC PROGRAM

There are 4 programs available in IF therapeutic mode. The therapeutic program can be 

selected by pressing the 

s

 and 

t

 buttons. The mode you selected will show up on the 

top of liquid crystal display.

SET TIMER

Press the 

S

 button to enter this setting. The treatment time is adjustable from 

to 

60

 minutes or Continuous. Press the 

s

 and 

t

 buttons to adjust setting. You 

can set the timer to “Continuous” mode by pressing the 

s

 control when it shows 

60 minutes. The output will be shut off when time is up. If in continuous mode, you 

need to manually turn off device.

SET INTERFERENCE FREQUENCY (OPTIONAL)

Channel 1 has 

4000

 Hz fixed fundamental frequency. Channel 2 has selectable 

frequency from 

4001

 to 

4150 

Hz; Interference frequency is adjustable from 

1

 Hz to 

150

 Hz. Only “P4” has this parameter setting. Press the 

S

 button to enter this 

menu, and then press the 

s

 and 

t

 buttons to adjusting the setting.

IF SETTING

2

1

3

1

2

3

2

4

PAGE 4 

 

QUICK REFERENCE GUIDE

Please see pages 37 and 38 of your LG QUAD Combo™ Instruction Manual for troubleshooting tips.

PROBLEMS WITH YOUR DEVICE?

SET CYCLE TIMER

Press 

S

 button after scrolling through and completing all settings to start the therapy 

program. The the 

s

 and 

t

 buttons can be used to increase 

s

 or decrease 

t

 the 

intensity level.

4

Press the 

S

 button to enter and cycle through 

to each setting state.

SET THERAPEUTIC PROGRAM

There are 3 programs available in MIC therapeutic program: 

Constant

Pulse Width 

Modulation

, and 

Pulse Rate Modulation

. The therapeutic program can be selected 

by pressing the 

s

 and 

t

 buttons. The mode you selected will show up on the top of 

LCD Display.

SET TIMER

Press the 

S

 button to enter this setting. The treatment time is adjustable from 

to 

60

 minutes or Continuous. Press the 

s

 and 

t

 buttons to adjust setting. You 

can set the timer to “Continuous” mode by pressing the 

s

 control when it shows 

60 minutes. The output will be shut off when time is up. If in continuous mode, you 

need to manually turn off device.

SET PULSE WIDTH

Pulse Width is adjustable from 

2

ms to 

200

ms. Press the 

S

 button to enter this menu, 

then press the 

s

 and 

t

 buttons to adjusting the setting.

SET PULSE RATE

Pulse rate is adjustable from 

1

 Hz to 

150

 Hz. Press the 

S

 button to enter this menu, 

and then press the 

s

 and 

t

 buttons to adjusting the setting.

SET CYCLE TIME (OPTIONAL)

Cycle time is adjustable form 

5

 to 

30

 seconds. Only modulation mode has this 

parameter setting. Press S button after scrolling through and completing all settings 

to start the therapy program. The the 

s

 and 

t

 buttons can be used to increase 

s

 or decrease 

t

 the intensity level.

MICROCURRENT SETTING

2

1

3

1

2

3

2

4

5

4

5

Live Pain Free, Live Good Today!

LG  QUAD Combo

Reviews: