background image

H

SI

L

G

N

E

L

O

Ñ

A

P

S

E

Room Air Conditioner

(Window Type)

OWNER'S MANUAL

WINDOW TYPE ROOM AIR CONDITIONER

• Please read carefully and thoroughly this manual 

before operating this unit.

• Contact the authorized SVC man for repair or 

maintenance of this unit.

• Contact the installer for installation of this unit.

• The appliance is not intended for use by young

children or infirm persons without supervision.

• Young children should be supervised to ensure

that they do not play with the appliance.

MODELS: W091CA

TSG0

(MODELOS) W092CA

TSG0

W121CA

TSC2

Antes de usar su aire acondionado, lea este manual

cuidadosamente y manténgalo para futura

referencia.

Aire Acondicionado

(Tipo de Ventana)

MANUAL DEL USUARIO

W182CA

 

TSN0 

W182CM

 

TSN0

W242CM

 

TSN0 

W242CA

 

TSN0

W182CMH

 

TSN1 

W081CM

 

TSG2 

W182CA

 

TSN2 

W182C

M

 

TSN

2

 

Summary of Contents for W081CM TSG2

Page 1: ...of this unit The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance MODELS W091CA TSG0 MODELOS W092CA TSG0 W121CA TSC2 Antes de usar su aire acondionado lea este manual cuidadosamente y manténgalo para futura referencia Aire Acondicionado Tipo de Ventana MANUAL DEL USUARIO ...

Page 2: ...troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensu...

Page 3: ...cates the possibility of injury or damage to properties only Meanings of symbols used in this manual are as shown below Be sure not to do Be sure to follow the instruction WARNING Installation Always install the expansion panel s No installation may cause fire and electric shock accident Do not place the power cord near a heater It may cause fire and electric shock Do not use the power cord near f...

Page 4: ...ower cord length It will cause electric shock or fire due to heat generation Do not share the outlet with other appliances It will cause electric shock or fire due to heat generation Always plug into a grounded outlet No grounding may cause electric shock See Installation Manual Unplug the unit if strange sounds odors or smoke come from it Otherwise it may cause fire and electric shock accident Do...

Page 5: ...sharp and may cause injury Do not block the inlet or outlet It may cause failure of appliance or accident Ensure that the outer case is not damaged by age or wear If leaving appliance damaged there is concern of damage due to the falling of product Be cautious not to touch the sharp edges when installing It may cause injury Hold the plug by the head when taking it out It may cause electric shock a...

Page 6: ...y cause injury Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use this appliance for special purposes such as cooling pets foods precision machinery or objects of art It is an air conditioner not a precision refrigeration system Always insert the filter securely Clean it every two weeks Operation without filters will cause fail...

Page 7: ...NOTICE Optional 7 H S I L G N E Location and Function of Controls Operating Instructions Controls The controls will look like one of the following Controls ...

Page 8: ...ime Cooling Select Low Cool with the Operation knob at the midpoint of Thermostat knob THERMOSTAT The THERMOSTAT is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the right side and the indoor air will become cooler The 5 or 6 position the middle position of arc is a normal setting f...

Page 9: ...e unit sets heating operation condition the green lamp is lighted When the frost settles on the heat exchanger of the outside defrosting is made automatically and the green lamp is turned off The unit may give a hiss and the fan motor stops for 1 to 10 minutes This should not be regarded as a problem After defrosting the heating operation begins again OPERATION OFF Turns the air conditioner off LO...

Page 10: ... temperature within a range of 16 C to 30 C 4 FAN SPEED SELECTOR Select the fan speed in three steps High F3 Low F1 Med F2 High F3 5 OPERATION MODE SELECTION BUTTON Select Cooling Fan or Dehumidification mode with this button 6 ON OFF TIMER BUTTON Set the time of starting and stopping operation The timer is set by 1 hour 7 SIGNAL RECEIVER AUTO RESTART In failure of electric power the unit runs as ...

Page 11: ...zontal louver and the vertical louver HORIZONTAL AIR DIRECTION CONTROL To control horizontal direction of air flow press the air flow direction control button and the air flow will be swept horizontally by the automatic air swing system If you want to stop the air flow from moving press the button again at the desired position of the vane VERTICAL AIR DIRECTION CONTROL The vertical air direction i...

Page 12: ...f the cabinet with 4 or 2 screws 4 Connect the drain hose to the outlet located at the bottom of the drain pan You can purchase the drain hose or tubing locally to satisfy your particular needs Drain hose is not supplied A drain hole is provided at the rear of the air conditioner unit Select a drain method according to the following 1 Remove the hole rubber from the base pan for some models 2 Conn...

Page 13: ...the air filter from the front grille assembly by pulling the air filter up or down slightly 3 Wash the filter using lukewarm water below 40 C 104 F c 4 Gently shake the excess water from the filter completely Replace the filter CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance Mark of inlet grille means opening direction NOTICE 1 ...

Page 14: ...ion will help you understanding the installation procedure Features 1 CABINET 2 HORIZONTAL AIR DEFLECTOR VERTICAL LOUVER 3 VERTICAL AIR DEFLECTOR HORIZONTAL LOUVER 4 AIR DISCHARGE 5 FRONT GRILLE 6 AIR INTAKE INLET GRILLE 7 AIR FILTER 8 CONTROL BOARD 9 POWER CORD 10 EVAPORATOR 11 CONDENSER 12 COMPRESSOR 13 BASE PAN 14 BRACE 15 REMOTE CONTROLLER Installation Hardware ...

Page 15: ...e no obstacle such as a fence or wall within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner 4 Install the unit a little obliquely outward not to leak the condensed water into the room about 10 15 mm or 1 4 bubble with level CAUTION All side louvers of the cabinet ...

Page 16: ...lots on the front of the case Push the grille in until it snaps into place 6 Lift the inlet grill and secure the front grille with a screw Lower the inlet grille into place When you detach the front grille from the case push the grille to your right side and pull it toward you Use the Reversible Inlet Grille 1 If you want to pull out the filter upward open the inlet grille slightly Turn inside out...

Page 17: ... Ice blocks the air flow and stops the air conditioner from cooling the room Make sure the air conditioner plug is pushed completely into the outlet Check the house fuse circuit breaker box and replace the fuse or reset the breaker If power failure occurs push power button to OFF When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Mak...

Page 18: ...Nota 19 ESPAÑOL ...

Page 19: ...P No MFL57207001 Printed in China After reading this manual keep it in a place easily accessible to the user for future reference ...