DIAGOSTIC TEST
11
27
40% ~ 60%
5% ~ 20%
-3 ~ +5 %
50 ~ 130
100 ~ 200
205 ~ 240
After Spinning
Iron dry
After normal dry
IMC
DISPLAY
NOTE
4
3
2
GN1(RD4)
1
Metal Wire
NO
NO
NO
YES
YES
Test 6 Thermistor check
Trouble Symptom : Drying Failure
Measurement condition : Power cord is unplugged.
With CN1(RED4)
disconnected from Controller,
CN1
-CN1
resistance is
unlimited?
With metal tape attached to
Sensor tips, CN1
-CN1
resistance is less than 10
Ω
?
After damp clothes touch
Sensor tips,
the range are within the
below table when QA-test?
• Check Harness
• Check if Sensor tips
have foreign objects
- Refer to the left picture
• Check Harness
- Open, Connector is
disconnected
• Check and replace
Controller