background image

MODELS
SP121CA

NL0

SP121CA

US0

SP122CA

NL0

SP122CA

US0

SP182CA

NL0

SP182CA

US0

SP242CA

NL0

SP242CA

US0

WALL MOUNTED

www.lg.com

Please read this manual carefully before operating
your set and retain it for future reference.

OWNER’S MANUAL

AIR

CONDITIONER

ENGLISH

ESP

AÑOL

 

Summary of Contents for SP121CA NL0

Page 1: ...122CA NL0 SP122CA US0 SP182CA NL0 SP182CA US0 SP242CA NL0 SP242CA US0 WALL MOUNTED www lg com Please read this manual carefully before operating your set and retain it for future reference OWNER S MANUAL AIR CONDITIONER ENGLISH ESPAÑOL ...

Page 2: ...h national regulations for electrical installations Do not cool excessively indoors This may be harmful for your health and may consume more electricity Block sunlight with blinds or curtains while you are operating the air conditioner Keep doors or windows closed tightly while you are operating the air conditioner Adjust the direction of the air flow vertically or horizontally to circulate indoor...

Page 3: ... the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an Authorized Service Center There is risk of fire electric shock explosion ...

Page 4: ...arly Oxygen deficiency could occur and hence harm your health Do not open the front grille of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric shock or product failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electr...

Page 5: ...nd installing the product Sharp edges could cause injury If the refrigerant gas leaks during the repair do not touch the leakaing refrigerant gas The refrigernat gas can cause frostbite cold burn Do not tilt the unit when removing or uninstalling it The condensed water inside can spill Do not mix air or gas other than the specified refrigerant used in the system If air enters the refriger ant syst...

Page 6: ...NG INSTRUCTIONS 9 How to insert the Batteries 9 Wireless Remote Controller Maintenance 9 Operating Method 10 Wireless Remote Controller 11 Operation Mode 12 Auto Mode 12 Cooling Mode 13 Dry Mode 13 Fan Only Operation Mode 14 Timer Mode Timer On 14 Timer Mode Timer Off 15 Sleep Mode 15 Emergency Functio 16 MAINTENANCE AND SERVICE 17 Cleaning the Dual Protection Filter 17 Self Diagnosis Function 18 ...

Page 7: ...nections use only a genuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity con nection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal dama...

Page 8: ...Horizontal blade Outdoor Unit Operation Indication Lamps POWER Light up while it is plugged in SLEEP Light up during sleep mode auto operation TIMER Light up during timer operation RUN Light up during the system operation Indoor Unit Standard split Type Display panel LED indicators PRODUCT INTRODUCTION Here is a brief introduction of the indoor and outdoor units Plase see the information specific ...

Page 9: ...orce in the country of use Wireless Remote Controller Maintenance 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder Operating Method 1 The signal receiver is inside the unit 2 Aim the remote controller towards the unit to operate it There should not be any blockage in be tween NOTE Rem...

Page 10: ...the timer operation 6 MODE Used to select the operation mode 7 Decrease the temperature or time by 1 unit 8 Increase the temperature or time by 1 unit Symbols Meaning AUTO mode indicator COOLING indicator DRY indicator FAN ONLY OPERATION indicator SIGNAL RECEPTION indicator TIMER OFF indicator TIMER ON indicator AUTO FAN indicator LOW FAN SPEED indicator MIDDLE FAN SPEED indicator HIGH FAN SPEED i...

Page 11: ...ted in the direction of the arrow For cooling operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 31 C Set the fan speed with the remote controller You can select the fan speed in four steps low middle high and auto wind by pressing the FAN BUTTON Each time the button is pressed the fan speed mode is shift...

Page 12: ...the indoor unit to en sure user comfort The cooling function allows the air conditioner to cool the room and the room and at the same time reduces the humidity in the air To activate the cooling function COOL press the button until the symbol COOL appears in the display The cooling cycle is activated by setting the keys s or t at a temperature lower than that of the room To optimize the functionin...

Page 13: ...cation func tion the fan speed is automatically set according to the optimization algorithm re sponding to the current room temperature status so that the room condition is kept healthy and comfortable even in the very humid season The conditioner works in only Ventilation To set the the Fan Only Operation Mode Press MODE until FAN appears in the display With pressing FAN button the speed changes ...

Page 14: ...e fan speed with the key FAN Switch the conditioner off with the key ON OFF To set the automatic switching off of the air conditioner The timed stop is programmed with the appliance on Press TIMER Set the time pressing the key or Press the key more times till on the display you can read the time which passes between the programming and the timed stop The timer is programmed in half hour increments...

Page 15: ...ter 60 minutes and by a further 1 C after another 60 minutes for a more comfortable sleep The temperature increases with up to 2 C from the preset temperature After 10 hours running is sleep mode the air conditioner is switched off automatically Sleep Mode If the remote control is lost proceed as fol lows Lift the unit front panel to reach the emergency button of the air conditioner if you press t...

Page 16: ...t with technician Dual Protection Filter CAUTION Turn off the power and unplug the power cord before you perform any maintenance other wise it may cause electric shock Never use water that is hotter than 40 C 104 F when you clean the filters It may cause deformation or discoloration Never use volatile substances when you clean the filters They may damage the surface of the product NOTE The locatio...

Page 17: ...ection Filter Clean the dual protection filter once every 2 weeks or more if necessary 1 Turn off the power and unplug the power cord 2 Open the front cover Lift up both sides of the cover slightly The feature can be changed according to type of model 3 Hold the knob of the dual protection filter lift it up slightly and remove it from the unit The feature can be changed according to type of model ...

Page 18: ...h a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Replace the fuse or check if the circuit breaker has tripped Fuse Type Time Delay 250 V 3 15 A A power failure has occurred Turn off the air conditioner when a p...

Page 19: ... ...

Page 20: ...20 ENGLISH ...

Page 21: ... S A DE C V Sor Juana Inés de la Cruz No 555 Col San Lorenzo Industrial Tlalnepantla de Baz Estado de México C P 54033 Teléfono 55 5321 1919 Pagina Web http www lg com mx 211357760 Rev 4 需要扫描 code 128 内容为物 料编码 Rev 4不 属于条码内容 ...

Reviews: