background image

OWNER’S MANUAL

AIR CONDITIONER

Please read this manual carefully before operating
your set and retain it for future reference.

P/NO : MFL66102309

www.lge.com

TYPE : WALL MOUNTED

MODELS :
S10INV-2

S13INV-2

AI

SE

N

O

D

NI

HS

IL

G

NE

Summary of Contents for S10INV-2

Page 1: ... AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference P NO MFL66102309 www lge com TYPE WALL MOUNTED MODELS S10INV 2 S13INV 2 A I S E N O D N I H S I L G N E ...

Page 2: ...th the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication Lamps 7 Outdoor Unit 7 D Operating...

Page 3: ...ireorelectricshockdueto dust wateretc Usethecorrectlyratedbreakerorfuse Thereisriskoffireorelectricshock Donotmodifyorextendthepowercable Ifthepowercableorcordhasscrathesor mustbereplaced Thereisriskoffireorelectricshock Forinstallation removalorreinstall alwayscontactthedealeroran AuthorizedServiceCenter Thereisriskoffire electricshock explosion orinjury Donotinstalltheproductonadefective install...

Page 4: ...uctfailure Ifstrangesound smellorsmokecomes fromproduct Immediatelyturnthebreaker offordisconnectthepowersupplycable Thereisriskofelectricshockorfire Ventilatetheproductroom fromtimeto timewhenoperatingittogetherwitha stove orheatingelementetc Oxygendeficiencycanoccurandhenceharm yourhealth Turnthemainpoweroffandunplugthe unitwhencleaningorrepairingthe product Thereisriskofelectricshock Whenthepro...

Page 5: ...tsystem an excessivelyhighpressureresults causing equipmentdamageorinjury Iftherefrigerantgasleaksduringthe installation ventilatetheareaimmediately Otherwiseitcanbeharmfullforyourhealth Dismantlingtheunit treatmentofthe refrigerantoilandeventualpartsshould bedoneinaccordancewithlocaland nationalstandards Replacetheallbatteriesintheremote controlwithnewonesofthesametype Donotmixoldandnewbatterieso...

Page 6: ...lable from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the appliance with a broken ...

Page 7: ...r outlet vents Base plate Lights up during the system operation Timer On Off Lights up during timer operation Lights up during plasma and Ion operation Plasma Ion Timer Power Plasma Ion LED Display Signal Receiver ON OFF Button Air Inlet Plasma Filter Ionizer Air Filter Vertical Louver H1N1 Filter Horizontal Vane Air Outlet Triple Filter ENGLISH Indoor Unit Operation Indication Lamps Outdoor Unit ...

Page 8: ...ectly 3 Reattach the cover by sliding it back into position 1 Always use replace both batteries of same type 2 If the system is not to be used for a long time remove the batteries to save their working life 3 If the display screen of remote controller starts fading replace both of the batteries 4 Use 2 AAA 1 5 volt batteries NOTE 3 In case some other appliances also get operated with remote contro...

Page 9: ...MPERATURE CHECKING BUTTON Used to check the room temperature 13 RESET BUTTON Used prior to resetting time 14 2nd F BUTTON Used prior to using modes printed in blue at the bottom of buttons 15 AUTO CLEAN BUTTON Used to set auto clean mode In some models this button has a 2nd function of LED luminosity control To use the functions printed in blue at the bottom of the buttons press 2 F button first a...

Page 10: ...ng operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON Each time the button is pressed the fan speed mode is shifted 1 2 3 4 Natural wind b...

Page 11: ...layed on the remote controller and you are not able to control the room temperature either During the healthy function the volume is automatically set according to the optimization algorithm responding to the current room temperature status so that the room condition is kept healthy and comfortable even in the very humid season 1 and 2 and 4 See operation mode AUTOCLEAN During auto clean function ...

Page 12: ...on 2 Press 2nd F button and check if icon is on 3 Press the TIME SETTING BUTTONS until the desired time is set 4 Press the TIME SET CANCEL BUTTON Check the indicator for A M and P M NOTE CANCEL SET temperature 12 Air Conditioner Energy Saving Cooling Mode Setting the Current Time PLASMA Purification Ion Generation Operation PLASMA Plasma filter is a technology developed by LG to get rid of microsc...

Page 13: ...vailable for 1 to 7 times To alter the time period in steps of 1 hour press the SLEEP MODE AUTO BUTTON while aiming at air conditioner 3 Make sure the Timer LED lights up To cancel the sleep mode press the SLEEP MODE AUTO BUTTON several times until the Timer LED lights off The sleep mode will operate indoor fan at slow speed in cooling mode and at medium speed in heating mode for pleasant sleep Th...

Page 14: ...quickly in hot summer When this function is turned on the air conditioner runs in cooling operation mode with super high fan speed and 18 cooling Similarly jet heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes You can activate this operation by pressing the JET COOL BUTTON To change from jet cool m...

Page 15: ...e controller sets If you want to use this operation Press and hold the ON OFF button for 3 5 seconds then the buzzer sound 1 beep If you want to stop the operation re press the button This feature is enabled by factory default setting but you can disable it by pressing the ON OFF button for 6 seconds The unit will beep twice and the lamp will blink 6 times To enable it press the button again for 6...

Page 16: ...y diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place The air filters behind the front panel grille should be checked and cleaned once in every 2 weeks or more often if necessory To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm...

Page 17: ...slightly forward to remove the air filter After removing the air filter remove the Plasma Triple filter and H1N1 filter by slightly pulling downwards Don t touch this Plasma Filter within 10 seconds after opening the inlet grille it may cause an electric shock Plasma Filter Owner s Manual 17 ENGLISH ...

Page 18: ...linds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room regularly lower cooling and Clean at least once every...

Page 19: ...age is unusually very high or low the circuit Breaker will trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner See the Maintenance and Service section you need to allow time for the room to cool down cold air returns Make sure they are correct Check and remove such source or turn it What To Do Possible Causes 1 Anything abnormal such as burning smell ...

Page 20: ...PT LG ELECTRONICS INDONESIA Kawasan Industri MM2100 Blok G Cikarang Barat Bekasi Jawa Barat 17520 INDONESIA ...

Page 21: ...AC Silakan baca buku petunjuk ini dengan seksama sebelum operasi Menetapkan dan mempertahankan Anda untuk referensi di masa mendatang TYPE AC Dinding Berlaku untuk model S10INV 2 S13INV 2 H S I L G N E A I S E N O D N I ...

Page 22: ... dengan AC Jika kabel daya harus diganti mintalah teknisi terlatih untuk melakukannya dengan menggunakan hanya suku cadang asli A Tindakan Pencegahan Keselamatan 3 B Keamanan Elektrik 6 Penggunaan Sementara Adaptor 6 Penggunaan Sementara Kabel Ekstensi 6 Simbol yang digunakan di Panduan ini 6 C Pengenalan Produk 7 Unit Dalam Ruangan 7 Lampu Indikasi Pengoperasian 7 Unit Luar Ruangan 7 D Instruksi ...

Page 23: ...atautersengatlistrik Pasangpaneldanpenutupkotakkontrol dengankencang Adarisikokebakaranatausengatanlistrikkarena debu air dsb Gunakanpemutusatausekringdengannilai Adarisikokebakaranatautersengatlistrik daya Jikakabeldayatergoresatauterkelupas ataurusak gantikabel Adarisikokebakaranatautersengatlistrik Untukpemasangan pelepasan atau pemasangankembali hubungiselaludealer atauPusatServisResmi Adarisi...

Page 24: ...agalanproduk Jikakeluarbunyianeh bautidakenak atau asapdariproduk segeramatikanunitpemutus ataucabutkabelcatudaya Adarisikosengatanlistrikataukebakaran Lakukanpertukaranudaradariwaktukewaktu saatdioperasikanbersamadengankompor atauelemenpemanasdsb Kandunganzatoksigendapatberkurangdan dapatmenganggukesehatanAnda Matikandayautamadanputuskan koneksiunitsaatprodukdibersihkan ataudiperbaiki Adarisikose...

Page 25: ...tkanperlengkapanrusakatautimbul Jikagasrefrigeranbocorselamapemasangan lakukansegerapergantianudaradiareayang Jikatidakdilakukandapatmembahayakan Membongkarunit menanganiolirefrigeran oildankomponenharusdilakukansesuai denganstandardisasisetempatdan nasional Gantisemuabateraidiremotecontrol dengantipeyangsama Jangankombinasikan baterailamadanbateraibaruataubaterai dengantipeyangberbeda beda Adaris...

Page 26: ... yang asli yang dapat ditemukan di banyak toko perlengkapan setempat Pastikan slot yang besar di adaptor berada lurus dengan slot besar di stop kontak untuk koneksi polaritas yang benar Untuk mencabut kabel daya dari adaptor pegang kabel daya dengan satu tangan dan tangan lainnya memegang adaptor untuk mencegah terminal ground rusak Jangan sering mencabut kabel daya karena ini dapat menyebabkan ke...

Page 27: ...atis Timer On Off Menyala selama pengoperasian timer atau pengoperasian otomatis mode sleep Fungsi ini melukiskan mode dinamik dengan menggunakan sistem pencahayaan multipel Plasma Ion Timer Power Plasma Ion Grildepan LED Display Penerima Sinyal Tombol ON OFF Inlet udara Plasma Filter Kisi Kisi Vertikal Ionizer Filter udara H1N1 Filter Bilah Horizontal Outlet Udara Triple Filter Kabel penghubung S...

Page 28: ...g baterai baru dengan memastikan bahwa sisi dan baterai berada di posisi yang benar 3 Pasang kembali penutup baterai dengan menggesernya kembali ke posisinya 1 Selalu gunakan ganti baterai dengan tipe baterai yang sama 2 Jika sistem AC tidak ingin digunakan dalam waktu yang cukup lama lepaskan baterai untuk menghemat masa pakainya 3 Jika layar display remote control mulai memudar ganti kedua bater...

Page 29: ...rasi Sleep Mode Auto 10 TOMBOL ENERGY SAVING MODE PENDINGIN Digunakan untuk memulai hemat energi modus pendingin operasi 11 TOMBOL PEMERIKSAAN SUHU RUANG Digunakan untuk mengecek temperatur ruang 18 TOMBOL PLASMA Digunakan untuk memulai atau menghentikan fungsi pemurnian plasma 17 TOMBOL HORIZONTAL AIRFLOW KONTROL ARAH Digunakan untuk menyetel arah aliran udara horizontal seperti yang diinginkan 1...

Page 30: ...ai arah panah Tutup pintu remote control Setel temperaturnya lebih rendah daripada temperatur ruang Temperatur bisa disetel dalam kisaran 16 C 30 C pada interval 1 C Setel kecepatan kipas lagi dengan pintu remote control dalam keadaan tertutup Anda dapat memilih kecepatan kipas dalam empat tingkat rendah medium tinggi atau ACAK Setiap kali tombol ditekan mode kecepatan kipas akan berubah Untuk men...

Page 31: ...si Dalam modus operasi ini sebenarnya pengaturan suhu dan kecepatan kipas secara otomatis ditetapkan oleh kontrol elektronik berdasarkan logika saat ini suhu kamar Jika Anda merasa panas atau dingin tekan pengaturan suhu tombol masing masing untuk lebih cooling atau efek pemanasan CATATAN Anda tidak dapat menetapkan pengaturan yang sebenarnya suhu dan kipas indoor kecepatan dalam modus operasi ini...

Page 32: ...erasian pendinginan 3 Tekan TOMBOL MODE PENDINGINAN HEMAT ENERGI 4 Untuk membatalkan mode pendinginan hemat energi tekan ulang TOMBOL MODE PENDINGINAN HEMAT ENERGI dan unit akan beroperasi dalam mode sebelumnya mode pendinginan CATATAN PLASMA Bersuci Ion Generasi Operasi PLASMA Penyaring plasma adalah teknologi yang dikembangkan oleh LG untuk menyingkirkan mikroskopis asupan kontaminan di udara de...

Page 33: ...tuk 1 kali hingga 7 kali Untuk mengubah masa waktu dalam langkah langkah interval 1 jam tekan tombol Mode Sleep dengan mengarahkan remote control ke unit 3 Pastikan LED dari Model Sleep Otomatis menyala Untuk membatalkan Mode Sleep tekan tombol Mode Otomatis beberapa kali hingga tanda bintang menghilang dari layar remote control Mode Sleep akan bekerja pada kecepatan kipas yang rendah pendinginan ...

Page 34: ...sama untuk membuat tubuh manusia merasa nyaman seperti sedang menikmati sepoi sepoi angin alami Selalu gunakan remote control untuk mengatur arah aliran udara naik turun Mengubah posisi bilah pengatur arah aliran udara vertikal secara manual dapat merusak AC Apabila unit AC dimatikan bilah pengatur arah aliran udara naik turun akan menutup saluran keluar udara dari unit AC PERHATIAN PERHATIAN Alir...

Page 35: ...ggunakan pengoperasian ini Tekan dan tahan tombol ON OFF selama 3 5 detik kemudian buzzer akan mengeluarkan bunyi bip 1 kali Jika Anda ingin menghentikan pengoperasian tekan lagi tombolnya Fitur ini diaktifkan pada pengaturan default pabrik namun Anda dapat menonaktifkannya dengan menekan tombol ON OFF selama 6 detik Unit akan mengeluarkan bunyi bip dua kali dan lampu akan berkedip 6 kali Untuk me...

Page 36: ...Bersihkan filter dengan penyedot debu atau air hangat bersabun Untuk kotoran yang membandel bersihkan dengan larutan deterjen dalam air hangat Setelah filter dibersihkan jemur di area yang tidak terkena sinar matahari langsung dan pasang kembali ke tempatnya Plasma Filter Opsional Filter plasma di belakang filter udara harus diperiksa dan dibersihkan setiap 3 bulan sekali atau lebih sering jika di...

Page 37: ...esehatan dan boros listrik Biarkan kerai dan tirai tertutup Jarang biarkan sinar matahari langsung masuk ke dalam ruangan saat AC dioperasikan Jaga agar suhu di dalam ruangan rata Atur arah aliran udara vertikal dan horizontal untuk memastikan suhu di dalam ruangan rata Pastikan pintu dan jendela tertutup rapat Hindari untuk terlalu sering membuka pintu dan jendela untuk mempertahankan udara dingi...

Page 38: ...mutus sirkuit akan mengalami gangguan Pastikan tidak ada tirai kerai atau perabot rumah tangga yang memblokir bagian depan AC Lihat bagian Perawatan dan Servis Jika AC pertama kali dinyalakan ruangan perlu waktu untuk mendingin Periksa apakah ada gril lantai unit pemanas dan saluran balik udara dingin yang terbuka Pastikan pengaturannya benar Periksa dan pindahkan sumber tersebut atau matikan saat...

Page 39: ...Panduan Pengguna 19 Memo INDONESIA ...

Page 40: ...20 AC Memo ...

Page 41: ...Panduan Pengguna 21 Memo INDONESIA ...

Page 42: ...PT LG ELECTRONICS INDONESIA Kawasan Industri MM2100 Blok G Cikarang Barat Bekasi Jawa Barat 17520 INDONESIA ...

Reviews: