background image

Part Description

Owner’s & Installation Manual 

5

ENGLISH

Wireless Remote Controller

LCD Screen

Slide door(Closed)

Part Description

Accessory

Holder(1EA)

Fixing Screw (2EA)

Owner's / Installation

Manual

AAA(1.5V)

Batteries(2EA)

Summary of Contents for PQWRCDF0

Page 1: ...uct Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly Owner s Installation Manual Visit us at http www lgservice com Models PQWRCDF0 PQWRHDF0 ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ...

Page 2: ...Override Setting 10 Group Control Setting 11 Owner s Instruction 12 Cooling Mode 12 Auto Operation Mode 13 Auto Changeover Mode 14 Dehumidification Mode 16 Heating Mode 17 Fan Mode 18 Temperature Setting Room Temperature Checking 19 Airflow Setting Optional 20 Sub Function 21 Plasma Purification Optional 21 Auto Clean Optional 22 LCD Luminosity Control Optional 22 Celsius Fahrenheit Switching Opti...

Page 3: ...d Caution are to call the user s attention to the possible danger Read and follow them carefully in order to prevent a safety accident Warning and Caution are indicated in this guide and the product itself to help protect the users from danger WARNING CAUTION WARNING Do not recharge or disassemble the batteries Do not dispose of batteries in a fire They may burn or explode If the liquid from the b...

Page 4: ...e the remote controller in a location exposed to direct sunlight Aim at the signal receptor on the wiress remote controller so as to operate Only One Signal receptor Signal receptor 7m Signal receptor The remote control signal can be received at a distance of up to about 7m Be sure that there are no obstructions between the remote controller and the signal receptor Block a strong light over the si...

Page 5: ...scription Owner s Installation Manual 5 ENGLISH Wireless Remote Controller LCD Screen Slide door Closed Part Description Accessory Holder 1EA Fixing Screw 2EA Owner s Installation Manual AAA 1 5V Batteries 2EA ...

Page 6: ...on OPTIONAL Used to start or stop Smart Clean CLEAR ALL Button Used to clear all timer ROOM TEMPERATURE SETTING Button Used to select the room temperature ON OFF Button Used to turn on off the unit INDOOR FAN SPEED SELECTION Button Used to select fan speed in four steps low medium high and chaos UP DOWN AIRFLOW Button Used to stop or start louver movement and set the desired up down airflow direct...

Page 7: ...or consult your serviceman 1 The signal receiver is inside the unit 2 Aim the remote controller towards the unit to operate it There should not be any blockage in between NOTE How to insert the Batteries Wireless Remote Controller Maintenance 1 Remove the battery cover by pulling it according to the arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly ...

Page 8: ... the set address in the display window The address display time and method can differ by the indoor unit type 2 Reset the remote controller to use the general operation mode 3 By using the TEMPERATURE SETTING button set the indoor unit address Setting range 00 FF 2 After setting the address press the ON OFF button toward the indoor unit 1 time 3 The indoor unit will display the set address to comp...

Page 9: ...n cause problems to the product user injury or property damage This must be set by an certificated installer and any installation or change that is carried out by a non certificated person should be responsible for the results In this case free service cannot be provided CAUTION Function Code Setting Code Press the ON OFF button toward the indoor unit 1 time 3 Reset the remote controller to use th...

Page 10: ...th the FAN SPEED button pressed press the RESET button 1 Press the ON OFF button toward the indoor unit 1 time 3 Reset the remote controller to use the general operation mode 4 Function Code Setting Code By using the TEMPERATURE SETTING button set function code and setting value Please refer the installer setting code table 2 Set to Master Set to Slave ...

Page 11: ... group control With the FAN SPEED button pressed press the RESET button 1 Function Code Setting Code By using the TEMPERATURE SETTING button set function code and setting value Please refer the installer setting code table 2 Press the ON OFF button toward the indoor unit 1 time 3 Reset the remote controller to use the general operation mode 4 Set to Master Check Master Slave Set to Slave ...

Page 12: ...re is higher than room temperature cooling wind isn t blow out Setting Temp Range 18 30 C 64 86 F 3 Cooling Mode Power Cooling Press the ON OFF button The unit will respond with beep sound 1 Press MODE button to select Cooling Mode 2 Press the JET COOL button The unit will operate in super high fan speed in cooling mode Wall mounted models operate power cooling mode for 30 minutes 3 To cancel the ...

Page 13: ...sired temperature again Set the desired temperature For Cooling Model The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature If you feel hot or cold press TEMPERATURE SETTING buttons for more cooling or heating effect You cannot switch the indoor fan speed It has already been set by the Auto Operation Mode rule You can set desired temper...

Page 14: ...n four stepss low medium high and chaos Each time the button is pressed the fan speed mode is shifted 4 This Function is only for Multi V SYNC H P model To lower the temperature To raise the temperature During Auto changeover Mode The air conditioner changes the operation mode automatically to keep indoor temperature When room temperature vary over 2 C 4 F with respect to setting temperature air c...

Page 15: ...om temperature is 20 C 68 F then operating mode is heating If you set the mode change temperature to 2 C 4 F when the room temperature up to 27 C 25 C 2 C 80 F 76 F 4 F the unit start cooling operation In Auto Changeover Mode Press the ROOM TEMPERATURE CHECKING button for 3 seconds The mode change temperature set before will be displayed 1 Press the TEMPERATURE SETTING button to set desired Mode C...

Page 16: ...midification mode on the operation selection button the indoor unit starts to run the dehumidification function automatically setting the room temp and air volume to the best condition for dehumidification based on the sensed room temp In this case the setting temp is not displayed in the Remote Controller and you are not able to control the room temp either During the healthy dehumidification fun...

Page 17: ...re heating wind isn t blow out 3 Set the fan speed again You can select the fan speed in four steps low medium high or chaos Each time the button is pressed the fan speed mode is shifted 4 Press the ON OFF button The unit will respond with beep sound 1 Press MODE button to select Heating Mode 2 Heating Mode This Function is only for H P model To lower the temperature To raise the temperature Setti...

Page 18: ...ep sound 1 Press MODE button to select Fan Mode 2 Natural Wind by the chaos Logic For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to chaos mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the chaos logic During Fan Mode The outdoor compressor doesn t work Have a function to circulate the indoor as it sends...

Page 19: ...e The cooling mode doesn t work if desired temperature is higher than room temperature Please lower the desired temperature Heating Mode The heating mode doesn t work if desired temperature is lower than room temperature Please increase the desired temperature Whenever press button the room temperature will be displayed within 5 seconds After 5 seconds it turns to display the desired temperature B...

Page 20: ...ural breeze Always use the remote controller to adjust the up down airflow direction Manually moving the vertical airflow direction louver by hand could damage the air conditioner When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system The left right horizontal airflow can be adjusted by using the remote control 1 Press the ON OFF button to start...

Page 21: ...essed again 2 PLASMA Purification only If you press the PLASMA button Plasma Purification operates Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air This function can be used in any operation mode and any fan ...

Page 22: ...unit is turned off the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation Also the louver is closed This dries up any remains of moisture cleans the unit internally 2 Press the LCD LUMINOSITY button It is comfortable when you feel that the display of the unit too bright Celsius Fahrenheit Switching Press the C F SWITCH button to change from Ce...

Page 23: ... SET CLEAR button to reserve or cancel the Smart Clean function You can set clear with out on or off Manual Smart Clean operation 1 When the unit stop press the SMART CLEAN button Smart Clean symbol will be displayed 2 To stop Smart Clean function press the SMART CLEAN button Smart Clean symbol will disappear If Auto Smart Clean is reserved the symbol will not disappear The brush clean a dust from...

Page 24: ...The timer lamp on the air conditioner and the display will go off 1 Press the TIMER button for 3 seconds 2 Press TIME SETTING buttons until the desired time is set Check the indicator for A M and P M 3 Press the SET CLEAR button NOTE Timer Sleep Timer On Timer Off 1 Press the TIMER button to turn timer on or off 2 Press TIME SETTING buttons until the desired time is set 3 Press the SET CLEAR butto...

Page 25: ...ungen Schiebeklappe geschlossen Kabellose Fernbedienung LCD Screen Bauteilbezeichnungen DEUTSCH Bedienungs Montageanleitung 5 Zubehör Halterung 1EA Halterung 1EA Bedienungs und Montageanleitung AAA 1 5V Batterien 2EA ...

Page 26: ...it der LED Anzeige Taste SMART CLEAN OPTIONAL Starten und Beenden der intelligenten Reinigungsfunktion Taste CLEAR ALL Sämtliche Timer löschen Taste zur EINSTELLUNG DER RAUMTEMPERATUR Einstellung der Raumtemperatur Netzschalter ON OFF Ein und Ausschalten des Gerätes Wahltaste LÜFTERGESCHWINDIGKEIT INNENGERÄT Dient zur Auswahl der Lüftergeschwindigkeit niedrig mittel hoch und Chaos AUTO SCHWINGEN T...

Page 27: ...werden Bitten Sie ggf einen Techniker um Hilfe 1 Der Signalempfänger befindet sich im Gerät 2 Richten Sie die Fernbedienung auf das Gerät Achten Sie darauf dass sich kein Hindernis zwischen Fernbedienung und Gerät befindet HINWEIS Einlegen der Batterien Pflege der kabellosen Fernbedienung 1 Schieben Sie die Batterieklappe zum Öffnen in Pfeilrichtung 2 Legen Sie die Batterien ein Achten Sie dabei a...

Page 28: ...tes erscheint Dauer und Art der Adressenanzeige können je nach Innengerätetyp variieren 2 Setzen Sie die Fernbedienung zurück um den allgemeinen Betriebsmodus einzustellen 3 Stellen Sie über die Taste zur TEMPERATUREINSTELLUNG die Innengeräte Adresse ein Einstellbereich 00 FF 2 Drücken Sie nach der Einstellung der Adresse einmal die Taste ON OFF in Richtung Innengerät 3 Das Innengerät zeigt darauf...

Page 29: ...er Sachschäden Die Einstellungen sollten von einem ausgebildeten Monteur vorgenommen werden Bei Einstellungen oder Änderungen die von unqualifizierten Personen vorgenommen wurden haftet die jeweilige Person für sämtliche Folgen In diesem Fall erlischt ebenfalls der Garantieanspruch VORSICHT Funktionskennung Einstellungskennung Drücken Sie einmal die Taste ON OFF in Richtung Innengerät 3 Setzen Sie...

Page 30: ...n Sie die RESET Taste 1 Drücken Sie einmal die Taste ON OFF in Richtung Innengerät 3 Setzen Sie die Fernbedienung zurück um den allgemeinen Betriebsmodus einzustellen 4 Funktionskennung Einstellungskennung 2Stellen Sie über die Taste zur TEMPERATUREINSTELLUNG die Funktionskennung sowie die Einstellungswerte ein Richten Sie sich dabei nach der Tabelle der Einstellungskennungen 2 Auf Master einstell...

Page 31: ...kt und betätigen Sie die RESET Taste 1 Funktionskennung Einstellungskennung 2Stellen Sie über die Taste zur TEMPERATUREINSTELLUNG die Funktionskennung sowie die Einstellungswerte ein Richten Sie sich dabei nach der Tabelle der Einstellungskennungen 2 Drücken Sie einmal die Taste ON OFF in Richtung Innengerät 3 Setzen Sie die Fernbedienung zurück um den allgemeinen Betriebsmodus einzustellen 4 Mast...

Page 32: ...ur eingestellt wird wird kein Kühlungsluft erzeugt Einstellbarer Temperaturbereich 18 30 C 3 Kühlungsmodus Schnellkühlung Drücken Sie die Taste Start Stop Daraufhin gibt das Gerät einen Signalton aus 1 Drücken Sie die Taste MODE und stellen Sie den Kühlungsmodus ein 2 Drücken Sie die Taste Jet Cool um die Schnellkühlung erwärmung zu starten An der Wand montierte Modelle können 30 Minuten lang im S...

Page 33: ...e Temperatur ein Für Kühlgeräte Temperatur und Lüftergeschwindigkeit werden von der elektronischen Steuerung gemäß der tatsächlichen Raumtemperatur automatisch eingestellt Falls Ihnen zu warm oder kalt ist drücken Sie die Tasten zur TEMPERATUREINSTELLUNG für kühlere oder wärmere Luft Die Lüftergeschwindigkeit der Innenanlage kann nicht umgeschaltet werden Sie wird direkt im Automatikbetrieb einges...

Page 34: ...e Einstellungen Langsam Mittel Schnell und CHAOS zur Verfügung Jedes Mal wenn die Taste gedrückt wird wird die Lüftergeschwindigkeit erhöht 4 Diese Funktion ist nur für Multi V SYNC WP Modelle möglich Temperatur verringern Temperatur erhöhen Während der Automatischen Betriebsunterbrechung Die Klimaanlage ändert den Betriebsmodus automatisch um die Raumtemperatur aufrecht zu erhalten Bei Temperatur...

Page 35: ...on 20 C wird der Betriebsmodus Heizen eingestellt Wenn die Temperatur für den Moduswechsel auf 2 C eingestellt wird startet das Gerät bei einer Raumtemperatur bis zu 27 C 25 C 2 C den Kühlungsbetrieb Halten Sie im automatischen Wechselbetrieb die Taste ZUR ÜBERPRÜFUNG DER RAUMTEMPERATUR drei Sekunden lang gedrückt Daraufhin wird die bereits eingestellte Temperatur angezeigt 1 2Stellen Sie mit den ...

Page 36: ...tet 3 Im Entfeuchtungsbetrieb Wenn Sie mit der Taste Operation Selection den Entfeuchtungsmodus wählen startet das Klimagerät die Entfeuchtungsfunktion und stellt Raumtemp und Luftmenge gemäß gefühlter Raumtemp automatisch auf die zur Entfeuchtung geeigneten Werte ein In diesem Fall wird die eingestellte Temperatur nicht auf der Fernbedienung angezeigt und die Raumtemperatur kann nicht verändert w...

Page 37: ...zeugt 3 Stellen Sie die Lüftergeschw erneut ein Diese Geschwindigkeit kann in vier Schritten eingestellt werden niedrig mittel hoch oder CHAOS Bei jedem Tastendruck wird der Modus der Lüftergeschwindigkeit umgeschaltet 4 Drücken Sie die Taste Start Stop Daraufhin gibt das Gerät einen Signalton aus 1 Drücken Sie die Taste MODE und stellen Sie den Heizmodus ein 2 Heizbetrieb Diese Funktion ist nur f...

Page 38: ...rbetrieb auszuwählen 2 Natürlicher Luftzug nach der CHAOS Logik Für ein erfrischenderes Gefühl als bei einer einzigen Lüftergeschwindigkeit drücken Sie den Wahlschalter Indoor Fan Speed und stellen Sie den CHAOS Modus ein In diesem Modus wird ein Luftzug erzeugt der einer natürlichen Briese ähnlich ist indem die Lüftergeschwindigkeit nach der CHAOS Logik automatisch verändert wird Im Lüfterbetrieb...

Page 39: ...modus ist nicht möglich wenn die gewünschte Temperatur höher als die Raumtemperatur eingestellt wird Bitte stellen Sie die gewünschte Temperatur geringer ein Heizmodus Der Heizmodus ist nicht möglich wenn die gewünschte Temperatur geringer als die Raumtemperatur eingestellt wird Bitte stellen Sie die gewünschte Temperatur höher ein Bei jedem Drücken der Taste wird die Raumtemperatur fünf Sekunden ...

Page 40: ...ter für den Auf und Abwärtsstrom zu verstellen Wenn Sie die Schlitze manuell bewegen könnte hierdurch die Klimaanlage beschädigen Wenn das Gerät nicht eingeschaltet ist wird das Luftgitter für den Auf und Abwärtsluftstrom den Luftventilator vom System abschließen Links rechts Horizontaler Luftstrom kann mit der Fernbedienung geregelt werden 1 Drücken Sie auf die Taste Start Stop um das Gerät einzu...

Page 41: ... Wenn Sie nur die PLASMA Taste drücken funktioniert nur die PLASMA Luftreinigung Die Plasmafilter Technologie wurde von LG entwickelt um die einströmende Luft durch Erzeugung eines Plasmas aus Elektronen mit hoher Ladung von mikroskopisch kleinen Verunreinigungen zu befreien Das Plasma beseitigt die Verunreinigungen vollständig und sorgt so für eine saubere und hygienische Raumluft Bei funktionsfä...

Page 42: ...r der Innenanlage bei jedem Ausschalten des Gerätes ohne Kühlung oder Entfeuchtung der Raumluft ca 30 Minuten lang weiter Die Luftklappe wird dabei geschlossen Hierbei wird überschüssige Feuchtigkeit beseitigt und das Gerät wird gereinigt 2 Drücken Sie die Taste LCD LUMINOSITY Eine zu helle Anzeige kann auf diese Weise auf eine angenehme Helligkeit eingestellt werden Umschalten zwischen Celsius un...

Page 43: ...ubrechen Diese Funktion kann bei ein oder ausgeschaltetem Gerät gestartet werden Manueller intelligenter Reinigungsbetrieb 1 Drücken Sie bei angehaltenem Gerät die Taste SMART CLEAN Daraufhin erscheint das Symbol für die intelligente Reinigung 2 Um die intelligente Reinigungsfunktion zu beenden drücken Sie die Taste SMART CLEAN Daraufhin wird das Symbol für die intelligente Reinigung ausgeblendet ...

Page 44: ...ge werden ausgeblendet 1 Halten Sie die TIMER Taste drei Sekunden lang gedrückt 2 Stellen Sie mit Hilfe der TASTEN ZUR ZEITEINSTELLUNG die gewünschte Uhrzeit ein Prüfen Sie auch die Einstellung A M vormittags oder P M nachmittags 3 Drücken Sie die Taste SET CLEAR HINWEIS Sleep Timer Timer ein Timer aus 1 Drücken Sie die Taste TIMER um den Timer ein bzw auszuschalten 2 Stellen Sie mit Hilfe der TAS...

Page 45: ...P No 3828A20580F Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...