Becon HVAC Solution

MFL61741651

      

Published on Jan. 6, 2022

Individual Controller

Summary of Contents for PQRCVCL0QW

Page 1: ...Becon HVAC Solution MFL61741651 Published on Jan 6 2022 Individual Controller ...

Page 2: ...TM HVAC Solution 1 General Information 2 Wired remote controller 3 Wireless remote controller ...

Page 3: ...TM HVAC Solution 1 General Information 1 1 Solution Overview 1 2 Control System List 1 3 Nomenclature ...

Page 4: ...3P4W 50 60Hz 380V Light Pump Etc Fan RS485 LGAP Master Ethernet LGAP Modbus Protocol IO Module PVDSMN000 Central Controller Integrated Controller Large size Central Controller Small size Power Distribution Indicator IO Module Individual Controller RS485 LGAP RS485 Modbus PDI Standard WHM PEXPMB000 ACS IO ACU IO Multi V 5 AHU Comm Kit PRCKA1 2 PRDCA0 2 PAHCMS000 AHU Control Kit PENKTH000 PRCKD21E P...

Page 5: ...control Max 16 indoor unit 2 remote controller control Temp sensing Basic Advanced function schedule function PREMTBB01 Simple PQRCVCL0Q W All IDU 64 x 120 x 15 2 6 inch mono Display Hard button Group control Max 16 indoor unit 2 remote controller control Temp sensing Basic function PQRCHCA0Q W All IDU 64 x 120 x 15 2 6 inch mono Display Hard button Group control Max 16 indoor unit 2 remote contro...

Page 6: ... The total cable length must not exceed 50m It can cause communication error 2 Group Control Master Slave Slave DC 12 V GND GND Signal DC 12 V Signal When controlling multiple indoor units with one remote controller you must change the master slave setting from the indoor units 3 Interlocked operation with the ventilation Master IDU Master Ventilation GND DC 12 V Signal When installing interlocked...

Page 7: ...nd ventilation products as below using various control methods Master Slave Master Slave Max 16 EA units Master Slave 2 Remote Controller Control cable Model name PZCWRC2 Length 0 25m Extension cable Model name PZCWRC1 Length 9 6m Group Control cable Model name PZCWRCG3 Length 0 25m 9 6m Cable 10EA Cable 2EA Cable 1EA Cable 1EA Ventilation product means general ventilation and DX ventilation Up to...

Page 8: ... Signification 1 Air con Control System and Accessory type P Part ACS C Part ACS for Brazil only 2 Product type REMT Wired remote controller 3 Grade type A Premium B Standard C Simple 4 Tool version 5 6 Serial number No Signification 1 Air con Control System and Accessory type P Part ACS 2 Product type WLSS Wireless remote controller 3 Grade type A Premium B Standard C Simple 4 Tool version 5 Seri...

Page 9: ...lution 2 Wired remote controller 2 1 Product Feature 2 1 1 Feature List 2 1 2 List of function 2 1 3 Compatibility List 2 2 Example of installing 2 3 Product Description 2 3 1 Premium 2 3 2 Standard 2 3 3 Simple ...

Page 10: ...ck O O O O O Advanced Schedule Timer O O O X X Additional Mode Setting O O O X X Time Display O O O X X humid Display O O X X X X Advanced Lock mode set point set point range on off Lock Advanced Lock Advanced Lock X X Filter Sign O O O X X EnergyManagement O O O X X Dual Set point Human detection Temp Humidity compensation Wi Fi pairing O O X X X X O X X X ETC Operation StatusLED O O O O O O O Ai...

Page 11: ...artly keeps set temperature by adjusting the wind direction automatically Refresh mode Adjust the temperature of the direct and indirect wind to create a comfortable and efficiency working environment Sub function Air Purify It makes the indoor air clean and pleasant Energy saving cooling This is a function that improves the user s comfort and power saving performance by raising the desired temper...

Page 12: ...rol of outdoor unit What is the SLC Smart load control function It is the function to operate by calculating the necessary efficiency from the indoor and outdoor temperature and humidity Smart Load Control selections can enhance the comfort of the building and maximize sav ings at the same time Step 0 Not use Step 1 Maximize energy savings and rate of temperature change is less important Step 2 Ba...

Page 13: ...provides cooling heating airflow around the living area where the occupants are located by using the Vision sensor Function setting Human detection mode Saving operation 1 OFF 2 On Off power saving 3 Temperature control 4 Energy saving operation based on activity Saving operation 1 OFF Not use the Human detection mode 2 On off power saving If it is not detected for setting time the product is turn...

Page 14: ...ntrol of indoor unit is New type set the number of installed zone damper 2 8 for New 8 zone Static pressure step Step 0 Not use 32 00 Step 1 11 32 01 32 11 Static pressure step setting can be set only for duct products This function can set the static pressure of the product in 11 steps If Static pressure step setting code 32 is used the Static pressure code 06 can not be used 2 set control Mode s...

Page 15: ...g Time limit control This function allows the indoor unit to operate only for the set time and automatically turn off the product up to 9 hours Energy setting ODU capacity This function sets the outdoor unit capacity manually to set the outdoor unit capacity refer ence value on the instantaneous power consumption display screen Target instantaneous power This is a function to manually set the Inst...

Page 16: ...it code 12 Celsius 12 00 Fahrenheit 12 01 This function sets the temperature unit displayed on the remote controller Celcious temperature unit code 17 1 C 17 00 0 5 C 17 01 This function is to set the unit for temperature control by 1 C or 0 5 C Emergency heater Not use Not use 18 00 0 Not use the emergency heater function Use Fan Off 18 01 xx 0 Fan On 18 01 xx 1 When the product is stopped due to...

Page 17: ...alled 41 02 Simple On Off 41 03 It is the function to set the usage of the indoor unit s CN_CC port D C Auto installation Automatically recognizes dry contact installation status D C Manual uninstalled Set to the uninstalled unused state regardless of whether dry contact is installed or not D C Manual installed Set to the installed used state regardless of whether dry contact is installed or not S...

Page 18: ...eating is maintained using a heater The priority cooling function is available when the emer gency heater is set to use 18 01 Maintenance time Once outdoor unit change over to cooling by cooling priority it returns to heating cycle after set time Outdoor temp for heater stages code 57 Not use 57 01 0 Not use 57 01 1 It is a function to set the outdoor unit cycle and the heater switching operation ...

Page 19: ...complete you can enter installer setting to check whether the set up has succeeded or failed If the code value is 68 03 setting is successful If the code value is 68 04 setting is failed If it fails you cannot use the Auto ESP function Instead of Auto ESP the conventional ESP setting method can be used UVnano Not Installed Installed UVnano is a function that sterilizes fans or filters using UV LED...

Page 20: ...malaya cooling Only for India Refer sub function Refer sub function X Display indoor temp Fan Speed Slow Low Medium High Super high Auto X Wind direction Up down swing Not display the icon Left right swing X Comfort wind Swirl X Indirect wind X Direct wind X Smart mode X X Refresh mode X X Sub function Air Purify Energy saving cooling X Robot cleaning manual X Electric Heater Humidification X Fan ...

Page 21: ...tep 0 Not use Step 1 Noise reduction low Step 2 Noise reduction high Refer to installer set ting code 48 X Defrost mode Step 0 Not use Step 1 Forced snow removal Step 2 Quick defrost Step 3 Forced snow removal Quick defrost Refer to installer set ting code 49 X Smart Load Control Step 0 Not use Step 1 4 X Low noise mode time X X Advanced fan speed auto Set Clear Refer to installer set ting code 51...

Page 22: ... direction 1 OFF 2 Direct 3 Indirect X X X Installer setting Human detection sensor Installation status X X X Sensing Period X X X Sensitivity X X X Temperature con trol option X X X Detection areas setting X X X External equip ment control Mode setting On Off Auto X X X User setting External device use Not use Use X X X External device type Motor Lighting Fan Heater Pump Others X X X On condition...

Page 23: ... X Guard timer code 33 0 minute 33 00 15 minutes 33 01 30 minutes 33 02 45 minutes 33 03 60 minutes 33 04 X X Energy monitoring Instantaneous power X X Display power consumption Year on year monthly Power consumption X X Operation time X X Weekly Power consumption X X Operation time X X Monthly Power consumption X X Operation time X X Yearly Power consumption X X Operation time X X Energy saving T...

Page 24: ...Manual 09 00 Auto 09 01 X Fixed air volume code 11 Variable 11 01 Fixed 11 02 X Display temperature unit code 12 Celsius 12 00 Fahrenheit 12 01 Refer to user setting Celcious temperature unit code 17 1 C 17 00 0 5 C 17 01 Refer to user setting Emergency heater Not use Not use 18 00 0 X Use Fan Off 18 01 xx 0 Fan On 18 01 xx 1 X Function control during group control code 19 Type 0 Use common functi...

Page 25: ...Simple On Off 41 03 X Calculated power comsumption data dis play code 43 Use 43 00 Not use 43 01 X X Comfort cooling step value setting code 44 Power saving effect low 44 00 Power saving Effect medium 44 01 Power saving Effect high 44 02 Refer to function setting Refer to function setting X Fan continuous opera tion code 46 Clear 46 00 Set 46 01 X ODU function master code 47 Slave 47 00 Master 47 ...

Page 26: ...es code 57 Not use 57 01 0 Not use 57 01 1 Temperature setting 57 02 T1 temp 57 02 xx T temp 57 03 xx X Temperature setting T1 T2 temp For version 2 09 or later You can select heating stages manu ally Heat pump Heater Heater Heat pump X X X Low noise mode priori ty code 58 ODU 58 00 RMC 58 01 X X Humidity sensing loca tion code 59 RMC 59 00 IDU 59 01 X X Hot water coil CN PTC code 60 Normal 60 00 ...

Page 27: ...vel3 Code PREMTA000 PREMTB100 PREMTBB10 PREMTB001 PREMTBB01 PQRCVCL0Q W PQRCHCA0Q W Installer setting Auto ESP code 68 Not use 68 00 Auto 68 01 Manual 68 02 xx X X Success 68 03 Fail 68 04 X X UVnano Not Installed Installed X X X Filter box Not Installed Installed X X X Server room 1 Usage setting Enable Disabled Number of IDU 2 IDU address 3 Interval 4 Overlap 5 Temperature differ ence X X X ...

Page 28: ...tandard Simple PREMTA000 PREMTBB10 PREMTB100 PREMTBB01 PREMTB001 PQRCVCL0Q PQRCVCL0QW PQRCHCA0Q PQRCHCA0QW Cassette 4way before Gen4 from Gen4 2way 1way before from Gen4 Duct high sensible Gen4 High Mid before Gen4 from Gen4 Low before Gen4 from Gen4 Built in before Gen4 from Gen4 FAU Gen2 Ceiling Suspended before Gen4 from Gen4 Console before Gen4 from Gen4 floor Standing before Gen4 from Gen4 be...

Page 29: ...m Standard Simple PREMTA000 PREMTBB10 PREMTB100 PREMTBB01 PREMTB001 PQRCVCL0Q PQRCVCL0QW PQRCHCA0Q PQRCHCA0QW Single Split H Inverter Cassette Duct Ceiling Suspended Single Split Standard Inverter Cassette Duct High Duct Mid Duct Low Ceiling Suspended Console Wall Mounted Floor Standing Multi 4way 1way Duct Mid Duct Low Ceiling Suspended Console Wall Mounted Therma V Split Mid Temp X X X X X Split...

Page 30: ...ly using provided screw after placing remote controller setup board on the place where you like to setup Please set it up not to bend because poor setup could take place if setup board bends Please set up remote controller board fit to the reclamation box if there is a reclamation box 4 socket reclamation box installation 2 socket reclamation box installation 2 Can set up Wired remote controller c...

Page 31: ...controller can control indoor units which has the address of mas ter indoor unit Slave indoor unit can not be individually controlled by Central controller 4 Dry contact can be allowed only in master indoor unit 5 It is possible to use wireless remote controller at the same time 6 In case that the group s indoor unit has an abnormal problem an error code will be displayed on the wired remote contr...

Page 32: ...ion Air purification Plasma Purification X X Air purifying Single Operation Operation based on Mater indoor unit 1 Operation based on Mater indoor unit 1 Energy saving cooling X Operation based on Master indoor unit Auto dry Robot Cleaning X X Ventilation device kit X X Heater X Operation based on Master indoor unit 1 Humidification X X Fan Auto X Operation based on Master indoor unit Comfort cool...

Page 33: ...ting of the master remote controller 8 The indoor unit operates based on the detected temperature according to the 2TH Slave setting of the master remote controller GND DC 12 V B Y R B Y R Signal GND DC 12 V Signal Master Slave 2 1 IDU Control 1 It is possible to connect IDU and ventilation with one wired remote controller Set IDU and Ventilation unit to Master 2 It is possible to use wireless rem...

Page 34: ...ontact and Central controller at the same time 4 In case of an abnormal problem an error code displayed for each product on the wired remote controller 5 Some functions are limited when multiple ventilation products are connected Check filter remain time Refrigerant leakage detection sensor installer setting Check auto addressing result Comfort cooling step setting 6 Please refer restricted functi...

Page 35: ...eration and setting status Touch screen Control of product operation and setting status 2 Back button Move to the previous setting screen 3 Home button Move to the default screen 4 Wireless reception port Receives wireless remote controller signal 5 Reset button Reset wired remote controller 2 Specification 1 Feature Power Supply DC 12 V From Indoor Unit Rated Current Max 0 152 A Compatible produc...

Page 36: ...ton When you save the menu s setting value 5 On Off button When you turn ON OFF the air conditioner 4 3 inch full color TFT LCD Touch button Multi Language Support Temp Humid sensing Schedule Timer6 Group control Indoor unit Ventilator interlocking 2 3 2 Standard n PREMTB100 PREMTBB10 2 Specification 1 Feature 3 Description Power Supply DC 12 V From Indoor Unit Rated Current Max 0 201 A Compatible...

Page 37: ...erations function 3 Airflow Button To select the airflows 4 Function Setting Button To select the additional operations function 5 Ventilation Button For interlocking operations of air conditioner and ventilator 6 Reservation Button To program the schedule 7 Up Down Left Right Button To change the settings in the menu 8 Room temperature To check the indoor temperature 9 ESC Button To exit from the...

Page 38: ...tton To select the fan speed 4 On Off Button To turn on off with a remote controller 5 Operation Mode Selection Button To select the operating mode 120 mm 64 mm 15 mm 2 3 3 Simple n PQRCVCL0QW PQRCVCL0Q PQRCHCA0QW PQRCHCA0Q For Hotel 2 Specification 1 Feature Power Supply DC 12 V From Indoor Unit Rated Current Max 0 085 A Compatible product Air conditioner Language English 3 Description 2 6 inch m...

Page 39: ...TM HVAC Solution 3 Wireless remote controller 3 1 Product Feature 3 1 1 Feature List 3 1 2 Function Description 3 1 3 Compatibility List 3 2 Product Description 3 1 1 Basic ...

Page 40: ...int set point range on off Lock X X X X X X X Filter Sign EnergyManagement Dual Set point Human detection Temp Humidity compensation Wi Fi pairing ETC Operation StatusLED Air purifying Wireless Remote Controller Receiver X X Display 2 inch mono Display Size W x H x D mm 51 x 153 x 26 Black Light Control for Screen Saver O Applied X Not applied It might not be indicated or operated at the partial p...

Page 41: ...function Function setting Air Purify It makes the indoor air clean and pleasant Air purify alone operation can be used only for dust sensor applied products Dust lamp always display Smart indicator It is a function to set to always display the status of fine dust on the display of products equipped with a dust sensor Setting for brightness of IDU display It is a function to control the brightness ...

Page 42: ...nction of the Wi Fi module connected to the indoor unit Installer setting Mode override code 0 Set to master 00 Set to slave 01 The operation master slave selection function is to avoid other mode opera tions It prevent the selection of opposite mode of the master indoor unit by the indoor units set as slaves Ceiling height code 1 Standard 11 Low 12 High 13 Very high 14 It is a function to change ...

Page 43: ...r temperature Fan Speed Slow Low Medium High Chaos Wind direction Up Down swing Left Right swing Up Down airflow direction Left Right airflow direction Direct wind Indirect wind Smart mode Refresh mode Sub function Function setting Air Purify Dust lamp always display Smart indicator Setting for brightness of IDU display Auto drying Auto clean Energy saving cooling Robot cleaning Smart clean Electr...

Page 44: ...g Installer setting Mode override code 0 Set to master 00 Set to slave 01 Ceiling height code 1 Standard 11 Low 12 High 13 Very high 14 Group control code 2 Set to master 20 Set to slave 21 Check master slave 22 Auxiliary heater code 2 Set to auxiliary heater 23 Cancel auxiliary heater 24 Check auxiliary heater installation 25 h Depending on the model some functions and the designs ex Icons and bu...

Page 45: ...lable Need to set up the IR Receiver product Better PQWRH C Q0FDB PWLSSB21H C Cassette 4way before Gen4 from Gen4 2way 1way before Gen4 from Gen4 Duct high sensible Gen4 High Mid before Gen4 from Gen4 Low before Gen4 from Gen4 Built in before Gen4 from Gen4 FAU Gen2 Ceiling uspended before Gen4 from Gen4 Console before Gen4 from Gen4 floor Standing before Gen4 from Gen4 before Gen4 from Gen4 Wall ...

Page 46: ...y is unavailable Need to set up the IR Receiver product Better PQWRH C Q0FDB PWLSSB21H C Single Split H Inverter Cassette Duct Ceiling Suspended Single Split Standard Inverter Cassette Duct High Duct Mid Duct Low Ceiling Suspended Console Wall Mounted Floor Standing Multi 4way 1way Duct Mid Duct Low Ceiling Suspended Console Wall Mounted Therma V Split Mid Temp X Split High Temp X mono block X ...

Page 47: ...ir quality always on setting If it press for 3 s Used to stop or start louver movement and set the desired up down airflow direction Used to set each vane angle Used to set the desired left right horizontal airflow direction Used to set airflow Used to set the time of sleeping operation Used to turn on off the unit Used to set the time of starting operation Used to select the room temperature Used...

Page 48: ... LG Electronics Inc All Rights Reserved Printed in Korea January 2022 The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system The specifications designs and information in this brochure are subject to change without notice ...