background image

ENGLISH

TÜRKÇE

P/NO : MFL67708325

INSTALLATION MANUAL

AIR

CONDITIONER

www.lg.com

TYPE :                     Modbus Gateway For Indoor Unit
MODEL : PDRYCB500

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring 
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it 
thoroughly.

Summary of Contents for PDRYCB500

Page 1: ...ndoor Unit MODEL PDRYCB500 Please read this installation manual completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly ...

Page 2: ...r RS 485 Owner s installation manual TABLE OF CONTENTS Safety Precautions 3 5 Specification 6 Name of each part 7 Installation Method 8 10 Setting method 11 1 Connecting Drycontact with Indoor unit PCBA and Modbus Controller 11 2 Setting Address 11 ...

Page 3: ...N This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage Be sure not to do Be sure to follow the instruction WARNING Installation Don t touch with the hands while the power is on Cause fire electric shock explosion or injury Product installation must be referred to a service center or installation shop Cause fire electric shock ex...

Page 4: ...ight of the product The product may get damaged or may break Do not install the product to a place that generates oil steam salt sulfuric gas etc Cause the product s deformation or failure Use standardized Product Cause product failure Do not change or extend power lines arbitrarily Cause fire or electric shock Do not give a shock to the product If you give a shock to the product it may cause the ...

Page 5: ...rdian s supervision Cause accidents and product failures Do not use for special purpose place such as conserving flora and fauna precision instruments art Otherwise it can cause property damage Remove the power plug when cleaning Cause fire or electric shock Do not place heavy objects on the power line Cause fire or electric shock Do not disassemble repair or modify the product Cause fire or elect...

Page 6: ...arity None Stop bits 1 Register Base 0 2 Data registers Register Name Range Notes 1 Operation 0 1 0 Stop 1 Run 30003 Indoor temperature 100 400 Degrees C 10 30100 Error alarm 0 1 0 No Error 1 Error 40001 Set Run Mode 0 4 0 Cooling 2 Fan 3 AI 4 Heating 40002 Set Temperature 180 300 Degrees C 10 40015 Set Fan Speed 1 3 1 Low 2 Middle 3 High ...

Page 7: ...1 EA For Connecting with indoor unit Installation Manual Side 1 2 ON 3 4 1 2 3 4 7 6 5 Others Screw 4 EA For installation 1 CN OUT 2 BUS A 3 BUS B 4 SW1 5 SWDIP 6 LED1 7 LED 01 03 G ENGLISH Indoor Unit Connector RS 485 Terminal RS 485 Terminal Reset Switch Setting Address Switch Refer Page 11 RS 485 Status LED Communication Status LED ...

Page 8: ...d Refer to the instruction and set up description 4 Set the switch according to the setting method Refer to the instruction and set up description 5 Secure PCB on adequate space inside of the indoor unit 1 Install the product on flat surface and install anchoring screws at more than 2 places Otherwise the central controller may not be anchored properly 2 Do not tighten anchoring screws too tightly...

Page 9: ...that secure the product 2 Position the rear case to the direction towards to the connector for convenient cable arrangement 3 Secure the rear case on the installation place using the supplied fixing screws 4 Remove knock out shapes on the rear case according to the connector s size and direction ...

Page 10: ...efer to the instruction and set up description 7 Tighten the fixing screws on the top and bottom of the case 1 Install the product on flat surface and install anchoring screws at more than 2 places Otherwise the central controller may not be anchored properly 2 Do not tighten anchoring screws too tightly It may cause deformation of the case 3 Do not deform the case at random It may cause malfuncti...

Page 11: ... press RESET switch to reflect the setting In case connect a Modbus controller with several product Address have to be set different from others Indoor unit PCBA CN_CC 1 2 ON 3 4 Modbus Controller 1 2 ON 3 4 1 2 ON 3 4 1 2 ON 3 4 1 2 ON 3 4 1 2 ON 3 4 1 2 ON 3 4 Status of switch 1 2 ON 3 4 1 2 ON 3 4 Address 1 Address 2 Address 3 Address 4 Address 5 Address 6 Address 7 Address 8 ON OFF 1 2 ON 3 4 ...

Page 12: ...12 Modbus Gateway For Indoor Unit ...

Page 13: ...nci Kısım Gaziler Caddesi No 2 45030 Manisa İrtibat Adresi Aydınevler Mahallesi İnönü Caddesi No 20 Küçükyalı Ofis Park A Blok 34854 Maltepe İSTANBUL Telefonu 0216 432 08 00 Telefaksı 0216 432 09 86 ÜRETİCİ FİRMA LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA ...

Reviews: