background image

LG Multi-Type Air Conditioner
(Built in Duct Type)

OWNER'S MANUAL

LG

IMPORTANT

• Please read this owner's manual carefully and thoroughly 

before installing and operating your room air conditioner.

• Please retain this owner's manual for future reference after 

reading it  thoroughly.

Prior to installation, this air-
conditioning unit must be 
submitted for approval by the 
utility service which provides 
electricity (EN 61000-2 Norm, 
EN 61000-3 Norm).

website http://www.lgservice.com
e-mail http://lgservice.com/techsup.html

ENGLISH

ITALIANO

ESPAÑOL

FRANÇAIS

DEUTSCH

Summary of Contents for Multi-Type

Page 1: ...om air conditioner Please retain this owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 Norm EN 61000 3 Norm website http www lgservice com e mail http lgservice com techsup html ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ...

Page 2: ... in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be s...

Page 3: ...Be sure to follow the instruction Installation Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product There is ...

Page 4: ...o the product Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not plug or unplug the power supply plug during operation There is risk of fire or electric shock Do not touch operate the product with wet hands There is risk of fire or electrical shock Do not place a...

Page 5: ... of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric sh...

Page 6: ...duct where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation 90 When the product is not be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Take car...

Page 7: ...lfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Use a firm stool or ladder when cleaning or maintaining the product Be careful and avoid personal injury Repla...

Page 8: ...oves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destr...

Page 9: ... is obtained 4 FAN Operation Button Used to circulate room air without cooling or heating 5 Fan Speed Button Used to set desired fan speed 6 Operation Mode Selection Button Used to select the operation mode Auto Operation Mode Cooling Operation Mode Soft Dry Operation Mode Heating Operation Mode except cooling model 7 Timer Cancel Button Used to cancel the timer 8 Timer Set Button Used to set the ...

Page 10: ...abnormal operation ex electronic quick start ELBA inverter type fluorescent lamp Signal transmitter Transmits the signals to the signal receptor 1 FAN Operation Button Used to circulate room air without cooling or heating 2 Cooling Operation Button 3 Soft Dry Operation Button Used to dehumidify without overcooling 4 Heating Operation Button Heat pump model only 5 Timer Set Button Used to set the t...

Page 11: ...PERATION FAN SPEED SUB FUNCTION SET TEMP Time AUTO SWING HI ZONE Operation unit Program set Room Temp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP Hour Min Week RESET Operating Instructions Set the Current Time and a day of the Week 1Press the button Each time the ...

Page 12: ... 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP 01 03 05 07 09 11 13 15 17 19 21 23 Time Program 4Press the Program button again to finish weekly programmining 1Press the Program button The remote controller is displayed like a picture Then and 01 is blinked 2Press the button Press button repeatedly until desired mode appears For example if you want Thu press button 4 times 3Select the time you w...

Page 13: ...in this week you may set a holiday 1 Press the Program button 2 Press the Week button Select the Tuesday 3 Press the Holiday button Then the remote controller will be displayed The outside rectangular means holiday 4 Press the Program button again to finish holiday setting Program Program 1 Press the Timer button to turn Timer on or off This function is used to turn on or turn off in several hours...

Page 14: ...t Filter Preheat Out door Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 Time Operation unit 3 1 4 2 Operating Instructions Operation Mode Cooling Mode Cooling Mode Soft Dry Mode Auto Mode Cooling Model Soft Dry Mode Heating Mode Auto Mode Heat Pump Model Operation Procedure 1st 2nd 3rd 4th On Off Button Operation Mode Selection Button Room Temperature Setting Button Indoor Fan Speed...

Page 15: ...AN SPEED SUB FUNCTION SET TEMP LO AUTO SWING ZONE Operation unit Program set RoomTemp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP HI AUTO SWING ZONE Operation unit Program set RoomTemp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On S...

Page 16: ...7 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP HI AUTO SWING ZONE Operation unit Program set RoomTemp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP HI Cooling Operation Soft Dry Operation Heating Operation Auto Operation Operation Display Operating Ins...

Page 17: ... LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP MED Operation Display AUTO SWING ZONE Operation unit Program set Room Temp MED LO AUTO JET Heater Defrost Filter Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEE...

Page 18: ...t door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP HI Cooling Operation Soft Dry Operation Heating Operation Auto Operation Operation Display AUTO SWING ZONE Operation unit Program set Room Temp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2...

Page 19: ...23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP LO AUTO SWING HI ZONE Operation unit Program set Room Temp LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP MED Operating Instructions FAN Operation 3 Each time Indoor Fan Speed button is pressed the fan speed mode is sh...

Page 20: ... Minute Set button for three seconds Then the operation mode shift to child lock mode and it is displayed CL in the operation display When you press any button in this time the remote controller is not converted to any selected mode and the CL is displayed in the remote controller for about three seconds But the Room Temperature function is operated in spite of child lock mode 2 To cancel the Chil...

Page 21: ...at the set temperature the set fan speed and then it will be in automatically turn off when the room temperature reaches the set temperature 0 5 C Helpful information Airflow speed and cooling capacity The cooling capacity indicated in the specification is the value when the fan speed is set to high and the capacity will be lower at low or medium fan speed High fan speed is recommended when you wi...

Page 22: ...Never use any of the followings Water hotter than 40 C Could cause deformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner 1 Clean the filter with a vacuum or warm soapy water If very dirty wash with a solution of detergent in lukewarm water If hot water 50 C or more is used filter may be deformed 2 After washing with water dry well in the shade 3 Re i...

Page 23: ...the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for your health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room ...

Page 24: ...ll exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for ...

Page 25: ...P No 3828A20394G Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...