Summary of Contents for MFL39817411

Page 1: ...R Please read this manual carefully before operating your set and retain it for future reference P NO MFL39817411 TYPE Standard Standard Libero Artcool Mirror Ceiling Cassette http www lghvac com www lg com ENGLISH FRANÇAIS ESPAÑOL ...

Page 2: ...to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Outdoor Unit 7 D Operating Instructions 8 How to insert th...

Page 3: ... securely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or a...

Page 4: ...t failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repa...

Page 5: ...used in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace...

Page 6: ...e strongly discourage the use of an adapter due to potential safety hazards For temporary connections use only a genuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal ...

Page 7: ...Air filter Air outlet Front grille ON OFF button Signal receiver Grille tab Flap Horizontal blade Louvers Vertical blades Ceiling Cassette Type Standard Libero Type Cabinet Air Discharge Air Inlet Signal receiver Front Panel Operation lamp Signal Receiver ON OFF button Air inlet Plasma filter Air filter Front grille Vertical louver Allergy free filter Air outlet Horizontal vane Horizontal vane Hor...

Page 8: ...creen of remote controller starts fading replace both of the batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to...

Page 9: ...from unit In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency Standard Libero Type Cooling Cooling lamp lights up during Cooling Operation Heating Heating lamp lights up during Heating Operation Plasma Plasma lamp lights up during Plasma Purification Operation During Air Circulation Operation Cooling lamp li...

Page 10: ...lear all timer ROOM TEMPERATURE SETTING Button Used to select the room temperature ON OFF Button Used to turn on off the unit INDOOR FAN SPEED SELECTION Button Used to select fan speed in four steps low medium high and chaos UP DOWN AIRFLOW Button Used to stop or start louver movement and set the desired up down airflow direction LEFT RIGHT AIRFLOW Button Optional Used to set the desired left righ...

Page 11: ... to set auto clean ROOM TEMPERATURE SETTING Button Used to select the room temperature ON OFF Button Used to turn on off the unit INDOOR FAN SPEED SELECTION Button Used to select fan speed in four steps low medium high and chaos HORIZONTAL VANE CONTROL Button Used to set the desired vertical airflow direction VERTICAL LOUVER CONTROL Button Used to set the desired horizontal airflow direction TIMER...

Page 12: ... Please attach the inform label inside of the door Please choose proper language depend on your country OPERATION INDICATION SCREEN SET TEMPERATURE BUTTON FAN SPEED BUTTON ON OFF BUTTON OPRATION MODE SELECTION BUTTON WIRELESS REMOTE CONTROLLER RECEIVER Some products don t receive the wireless signals AIR FLOW BUTTON SUBFUNCTION BUTTON FUNCTION SETTING BUTTON VENTILATION BUTTON OPTIONAL RESERVATION...

Page 13: ... is shifted in the direction of the arrow For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C 64 F 86 F and for heating the temperature range is 16 C 30 C 60 F 86 F Set the fan speed with the remote controller You can select the fan speed by pressing the INDOOR FAN SPEED SELECTO...

Page 14: ...ication Operation o If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON the product starts to run the dehumidification function It automatically sets the room temperature and airflow volume to the best condition for dehumidification based on the sensed current room temperature In this case however the setting temperature is not displayed on the remote controller and you ...

Page 15: ...g body adaptation time according to the change of time and temperature and adjusting desired temperature automatically 1 Press the ON OFF BUTTON to start the unit 2 Open the cover of the remote controller Select cooling operation 3 Press the ENERGY SAVING COOLING MODE BUTTON 4 To cancel the energy saving cooling mode press the ENERGY SAVING COOLING MODE BUTTON again and unit will operate in previo...

Page 16: ...cation operation Also the louver is closed This dries up any remains of moisture cleans the unit internally 1 Press the TIMER button for 3 seconds 2 Press TIME SETTING buttons until the desired time is set Check the indicator for A M and P M 3 Press the SET CLEAR button NOTE If you wish to cancel all timer setting press the CLEAR ALL or SET CLEAR button If you wish to cancel each timer setting pre...

Page 17: ... ON OFF button for 3 5 seconds then the buzzer sound 1 beep If you want to stop the operation re press the button This feature is enabled by factory default setting but you can disable it by pressing the ON OFF button for 6 seconds The unit will beep twice and the lamp will blink 8 times To enable it press the button again for 6 seconds The unit will beep twice and the blue lamp will blink 4 times...

Page 18: ...ver at the desired airflow direction h Up Down and Left Right Airflow function isnʼt shown on display of remote controller Standard Libero Type 1 Press the ON OFF BUTTON to start the unit 2 Press the horizontal airflow direction button Each time the button is pressed the airflow direction is changed in the direction of the arrow Press the Horizontal Airflow Direction button once more during Full A...

Page 19: ...ove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Plasma Filters The plasma filters behind the air filter should be checked and cleaned once in every 3 months or mor...

Page 20: ...eformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner Benzene SCOURING CLBARGER SINNER 1 Remove the Air filters n Take hold of the tab and pull slightly forward to remove the filter CAUTION When the air filter is to be removed do not touch the metal parts of the indoor unit It may cause an injury 2 Clean dirt from the air filter using a vacuum cleaner...

Page 21: ... temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects Clean at least once every two weeks Ventilate the room occasionally Since windows are kept closed it is a good idea...

Page 22: ...22 Multi Air Conditioner ...

Page 23: ...ditioning Division 1000 Sylvan Ave Englewood Cliffs NJ 07632 LGECI LG Electronics Canada Inc 550 Matheson Blvd East Mississauga Ontario L4Z 4G3 US 1 Please call the installing contractor of your product as warranty service will be provided by them 2 If you have service issues that have not been addressed by the contractor please call 1 888 865 3026 CANADA Service call Number 888 LG Canada 888 542 ...