LGE Internal Use Only
Copyright LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 13 -
ADJUSTMENT INSTRUCTION
1. Application
This document is applied to LP92C chassis 22” LCD Monitor
TV which is manufactured in Monitor Factory or is produced
on the basis of this data.
2. Designation
1) The adjustment is according to the order which is
designated and which must be followed, according to the
plan which can be changed only on agreeing.
2) Power Adjustment: Free Voltage
3) Magnetic Field Condition: Nil.
4) Input signal Unit: Product Specification Standard
5) Reserve after operation: Above 5 Minutes (Heat Run)
Temperature : at 25°C±5°C
Relative humidity : 65 ±10%
Input voltage : 220V, 60Hz
6) Adjustment equipment: Color Analyzer (CA-210 or CA-
110), Pattern Generator (MSPG-925L or Equivalent), DDC
Adjustment Jig equipment, SVC remote controller
7) Don’t push The
“IN STOP KEY”
after completing the
function inspection.
3. Adjustment items
PCB assembly adjustment items
1) Download the MSTAR main software (IC603, Mstar ISP
Utility)
2) Auto Color Balance(ADC) - RGB
3) Auto Color Balance(ADC) – Component
4) Input Tool-Option/Area option.
5) Check SW Version.
SET assembly adjustment items
1) DDC Data input.
2) HDCP data input
3) Adjustment of White Balance.
4) Preset CH information
5) Factoring Option Data input.
4. PCB assembly adjustment method
4.1 Input Tool-Option, Area Option
Option adjustment following BOM (Tool Option 1, Area Option)
* Required Equipments
- Remote controller for adjustment
* Profile : Must be changed the option value because being
different with some setting value depend on module
maker, inch and market.
Adjustment method
The input methods are same as other chassis.(Use IN-START
Key on the Adjust Remocon.)
1) Push the IN-START key in the Adjust R/C.
2) Input the Option Number that was specified in the BOM, into
the Shipping area.
3) Select “Tool Option/ Area Option” by using
E
/
D
(CH+/-) key
, and press the number key(0~9) consecutively
ex) If the value of Tool Option1 is 7, input the data using
number key “7”
(If not changed the option, the input menu can differ from the
model spec.)
* Refer to Job Expression of each main chassis ass’y
(EBTxxxxxxxx) for Option value
* Before PCB check, you have to change the Tool option,
Areaoption and have to AC off/on (Plug out and in)
(If missing this process, set can operate abnormally)
* Never push the IN-STOP KEY after completing the function
inspection.
4.2 S/W program download
(Using MSTAR Download program)
Profile : This is for downloading the s/w to the flash memory of
IC603
Equipment
1) PC
2) ISP_tool program
3) Download jig
Connection structure
Connection condition
1) IC name and circuit number : Flash Memory and IC603
2) Use voltage : 3.3V (5 pin)
3) SCL : 15 pin
4) SDA : 12 pin
5) Tact time : about 2min
F L W 9 1 A L P L L 2 2 F H D
M a i n V 1 . 0 0
HDCP 0
F U T T X X
Tool Option 1 37000
Tool Option 2
112
Area Option
20
Summary of Contents for M227WAP
Page 32: ......