9-16
CHECKING FLOW CHART BY FAIRURE
Oven sensing error
→
→
F-1, F-2, F-4, F-5 error
Disconnect the oven sensor and check the value
(measure the resistance after cooling down)
Normal:approximately 1.06k
Ω
at 65°F ~ 1.12 k
Ω
at 85°F.
Normal?
No
Yes
Normal?
Replace the SYSTEM PCB
(EBR43296803)
No
Yes
Replace the Relay PCB
(EBR64624603)
1
END
END
Replace the oven sensor
END