4-2
Door locking Motor
Door locking micro
switch
(normally close type)
Low Voltage
Transformer - Halogen
lamp
1. Refer to page 3-10 for disassembly
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-10 for disassembly
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-2 for disassembly
2. Measure the resistance
(Multiple meter scale: R x 1)
Normal: Approximately
9.8
Ω
± 10%
Replace if: Infinite or below 1
Ω
Components
Test procedures
Results
NO
COM
Normal: Approximately 2550
Ω
Replace if: Infinite (opened)
below 5
Ω
(shorted)
Door latch
open
Door latch
Locked
Continuity
Infinite
NOTE:
After checking for the continuity of switch, make sure to reconnect leads
properly.