Replace the access cover on the range back. To
replace the wire cover, insert double projections in the
pockets located below the opening and tighten the
three screws.

ANTI-TIP DEVICE INSTALLATION

1. 

Locate the bracket using the template

An Anti-tip bracket is packaged with template. The
instructions include necessary information to
complete the installation. 
Read and follow range installation instruction sheet
(template).

2. 

Level the range

Level the range by adjusting the leveling legs with a
wrench.

9

Use a spirit level to check your adjustments. Place the
level diagonally on the oven rack, and check each
direction for level. 

First check direction  

1

.

After check direction  

2

.

If the spirit level doesn’t show 
level on the rack, adjust the 
leveling legs with a wrench.

FINAL INSTALLATION

• Move range close enough to the opening to plug

into the receptacle.

• Slide range into position insuring that the left back

leg slides under the anti-tip bracket. Range will sit 0”
away from the back wall when properly installed.

• Carefully tip range forward to insure that the anti-tip

bracket engages the range back brace and prevents
tip-over.

• Turn on electrical power. Check range for proper

operation as described in owner’s manual.

5

6

Part 4

INSTALL THE RANGE

WARNING

• DO NOT step or sit on oven

door. Install the Anti-Tip
Bracket supplied with the
range.

- The range could be tipped and

injury might result from spilled hot
liquid, food, or the range itself.

- If the range is pulled away from  the

wall for cleaning, service, or any
other reason, ensure that the Anti-
Tip Device is properly reengaged
when the range is pushed back
against the wall.

Summary of Contents for LFRF0222S

Page 1: ...InstallationManual Electric Range LFRF0222S Please read these instructions thoroughly before installing and operating the range P No MFL40441501 ...

Page 2: ... homes recreational vehicles and installations where local codes do not allow grounding through the neutral wire require a 4 conductor UL listed range cord or 4 wire conduit connection The middle neutral or ground wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connecte...

Page 3: ...rings around the range can withstand the heat generated by the range To eliminate the need to reach over the surface elements cabinet storage space above the elements should be avoided TOOLS NEEDED PREPARE TO INSTALL THE RANGE PARTS NOT PROVIDED WARNING The information in this manual should be followed exactly A fire or electrical shock may result causing property damage perasonal injury or death ...

Page 4: ...ss steel 0 024 0 610 mm aluminum or 0 020 0 508 mm copper 15 38 1 cm minimum between countertop and adjacent cabinet bottom FIGURE 1 FIGURE 2 A 30 76 2 cm For U S A 30 76 2 cm 31 78 7 cm For CANADA CAUTION Make sure that the wall covering countertop and cabinets around the range can withstand the heat up to 194 F generated by the range Discoloration delamination or melting may occur This range has...

Page 5: ... accordance with the National Electrical code ANSI NFPA NO 70 latest edition All wiring should conform to Local and NEC This range requires a single phase 3 wire A C 120 208V or 120 240V 60Hz electrical system Use only a 3 conductor or a 4 conductor UL listed range cord with closed loop terminals open end spade lugs with upturned ends or similar terminations Cord must have the strain relief proper...

Page 6: ...ctrical shock severe personal injury or death Install the power cord as follows For power cord installations Hook the strain relief over the power cord hole 13 8 located below the rear of drawer body Insert the power cord through the strain relief and tighten it Refer to Figure 7 You must install the power cord with a strain relief 1 Remove the lower 3 screws from the terminal block and retain the...

Page 7: ...n relief with its ring Reinstall the bracket For conduit connections If the wire in the conduit is copper it must be 8 or 10 AWG wiring If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring 1 Loosen the lower 3 screws from the terminal block Refer to Figure 11 2 Insert the bare wire white neutral end through the center terminal block opening Do not remove ground strap connections 3 I...

Page 8: ...3 Remove ground strap and discard as shown in Figure 12 Do not discard any screws 4 Attach the ground bare wire end to range frame and secure it in place with the ground screw Refer to figure 12 5 Insert the bare wire white neutral end through the center terminal block opening 6 Insert the two side bare wire ends into the left and the right terminal block opening Tighten the 3 screws securely into...

Page 9: ...evel on the rack adjust the leveling legs with a wrench FINAL INSTALLATION Move range close enough to the opening to plug into the receptacle Slide range into position insuring that the left back leg slides under the anti tip bracket Range will sit 0 away from the back wall when properly installed Carefully tip range forward to insure that the anti tip bracket engages the range back brace and prev...

Page 10: ......

Reviews: