5-11
COMPONENTS
TEST PROCEDURE
RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Measure the resistance.
(Ohm-meter scale: R x 1)
Normal:
A:Approx. 85 ~ 100 ohm.
B:Approx. 10 ~ 25 ohm.
Abnormal: Infinite or several
ohm.
Normal: Approx. 100 ~ 150 ohm
Abnormal: Infinite or several
ohm.
POWER
LEVEL
1
2
3
4
5
6
7
8
9
10
4 sec
6 sec
8 sec
10 sec
12 sec
14 sec
16 sec
18 sec
20 sec
22 sec
18 sec
16 sec
14 sec
12 sec
10 sec
8 sec
6 sec
4 sec
2 sec
0 sec
Measure the resistance.
(Ohm-meter scale: R x 1)
Summary of Contents for LCRT2010ST
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 28: ... 6 2 DOOR PARTS 13581A 13551A 13213A 13552A 13536A 14026A 14970A EV ...
Page 29: ... 6 3 CONTROLLER PARTS 24781M 23550D 24510L 24970A 23551B 268711 WTP018 23551A EV ...
Page 31: ... 6 5 LATCH BOARD PARTS WSZ085 WTT028 56912B 55262A 466001 466003 466001 43500A 43501A EV ...
Page 33: ... 6 7 BASE PLATE PARTS 63302A WTT021 56170D WSZ002 65006B 63303A EV ...
Page 34: ... 6 8 SENSOR PARTS 56501A WSZ002 WTP004 54974T EV ...
Page 35: ......