NO
COM
NC
COM
NO
COM
A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible
click
should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible
click.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-8
INTERLOCK CONTINUITY TEST
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO.SZM-V 16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH
COMPONENTS TEST
PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are
connected correctly.
Summary of Contents for LCRT2010ST
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 28: ... 6 2 DOOR PARTS 13581A 13551A 13213A 13552A 13536A 14026A 14970A EV ...
Page 29: ... 6 3 CONTROLLER PARTS 24781M 23550D 24510L 24970A 23551B 268711 WTP018 23551A EV ...
Page 31: ... 6 5 LATCH BOARD PARTS WSZ085 WTT028 56912B 55262A 466001 466003 466001 43500A 43501A EV ...
Page 33: ... 6 7 BASE PLATE PARTS 63302A WTT021 56170D WSZ002 65006B 63303A EV ...
Page 34: ... 6 8 SENSOR PARTS 56501A WSZ002 WTP004 54974T EV ...
Page 35: ......