Performance:

Capacity

 

(Btu/h)

18,200

SEER

20.5

EER

12.6

Cooling:

Heating:

Capacity

 

(Btu/h)

22,000

HSPF

9.7

Cooling

 

Nominal

 

Test

 

Conditions:

Heating

 

Nominal

 

Test

 

Conditions:

Indoor:

80°F

 

DB/67°F

 

WB

Indoor:

70°F

 

DB/60°F

 

WB

Outdoor: 95°F

 

DB/75°F

 

WB

Outdoor: 47°F

 

DB/43°F

 

WB

Electrical:

MCA

 

(A)

19

MOP

 

(A)

30

Fan

 

Motor

 

(A)

0.75

Outdoor

 

Unit:

Cooling

 

Rated

 

Amps

 

(A)

17.0

Heating

 

Rated

 

Amps

 

(A)

17.0

Indoor

 

Unit:

Cooling

 

Power

 

Input

 

(kW)

1.44

Heating

 

Power

 

Input

 

(kW)

1.76

Piping:

Liquid

 

Line

 

(in,

 

OD)

3/8

Additional

 

Refrigerant

 

(oz/ft)

0.38

Max

 

Elevation

 

(ft)

49

Piping

 

Length

 

(no

 

add'l

 

refrigerant,

 

ft)

25

Power

 

Supply

 

(V¹/Hz/Ø)

208

230/60/1

Max

 

Pipe

 

Length

 

(ft)²

98

Compressor

 

(A)

14.6

Vapor

 

Line

 

(in,

 

OD)

5/8

Features:

Operating

 

Range:

Outdoor

 

Unit:

Indoor

 

Unit:

Unit

 

Data:

Refrigerant

 

Type

R410A

Refrigerant

 

Charge

 

(lbs)

3.97

Fan:

Standard

 

Features:

 

•Limited

 

Five

 

Year

 

Compressor

 

Warranty

 

•Limited

 

Three

 

Year

 

Func onal

 

Parts

 

Warranty

Notes:

 

1.Acceptable

 

opera ng

 

voltage:

 

187V

 ‐ 

253V.

 

2.Piping

 

lengths

 

are

 

equivalent.

 

3.Sound

 

Pressure

 

levels

 

are

 

tested

 

in

 

an

 

anechoic

 

chamber

 

under

 

ISO

 

Standard

 

1996.

 

4.All

 

communica on

 

cable

 

to

 

be

 

minimum

 

18

 

AWG,

 

2

conductor,

 

stranded,

 

shielded

 

and

 

must

 

comply

 

with

 

applicable

 

local

 

and

 

national

 

code.

 

5.See

 

Engineering

 

Manual

 

for

 

sensible

 

and

 

latent

 

capaci es.

 

6.Power

 

wiring

 

cable

 

size

 

must

 

comply

 

with

 

the

 

applicable

 

local

 

and

 

na onal

 

code.

 

7.The

 

indoor

 

unit

 

comes

 

with

 

a

 

dry

 

helium

 

charge.

 

8.This

 

data

 

is

 

rated

 

0

   

above

 

sea

 

level,

 

with

 

24.6

   

of

 

refrigerant

 

line

 

and

 

a

 

0

   

level

 

di

erence

 

between

 

outdoor

 

and

 

indoor

 

units.

  

9.Must follow installa on instruc ons in the applicable LG installa on manual.

ODU

 

Type

Propeller

IDU

 

Type

Cross

 

Flow

Motor/Drive

Brushless

 

Digitally

 

Controlled/Direct

Dehumidification

 

(pts/hr)

5.5

Refrigerant

 

Control

EEV

Heat

 

Exchanger

 

Coating

GoldFin™

ODU

 

Net

 

Unit

 

Weight

 

(lbs)

133

ODU

 

Shipping

 

Weight

 

(lbs)

142

IDU

 

Net

 

Unit

 

Weight

38

IDU

 

Shipping

 

Weight

 

(lbs)

42

Fan

 

Speeds

 

(Fan/Cooling/Heating)

5/6/6

Quantity

 

(ODU

 

+

 

IDU)

1

 

+

 

1

IDU

 

Max

 

Air

 

Flow

 

H/M/L

 

(CFM)

600/510/420

ODU

 

Max

 

Air

 

Flow

 

Rate

 

(CFM)

2,119

Communication

 

Cable

 

(No

 

x

 

AWG)

4

 

x

 

18

Cooling

 

(°F

 

DB)

14

118

Heating

 

(°F

 

DB)

5

75

Cooling

 

(°F

 

DB)

64

90

Heating

 

(°F

 

DB)

61

86

ODU

 

Sound

 

Pressure

 

Max

 

(±3

 

dB(A))³

53

IDU

 

Sound

 

Pressure

 

(H/M/L)

 

(±3

 

dB(A))³

45/40/35

Power

 

Supply

 

(V¹/Hz/Ø)

208

230/60/1

Optional

 

Accessories

 

(sold

 

separately):

7

Day

 

Programmable

 

Controller

 

(Black)

 ‐ 

PQRCVSL0

7

Day

 

Programmable

 

Controller

 

(White)

 ‐ 

PQRCVSL0QW

Indoor

 

Unit

 

(IDU)

LAN180HSV2

Outdoor

 

Unit

 

(ODU)

LAU180HSV2

PI485

 ‐ 

PMNFP14A0

SEER

 ‐ 

Seasonal

 

Energy

 

Efficiency

 

Ratio

    

EER

 ‐ 

Energy

 

Efficiency

 

Ratio

   

HSPF

 ‐ 

Heating

 

Seasonal

 

Performance

 

Factor

MOP

 ‐ 

Maximum

 

Overcurrent

 

Protection MCA

 ‐ 

Minimum

 

Circuit

 

Ampacity

 

•4

Way

 

auto

 

swing

 

•24

Hour

 

on/o

ff 

mer

 

•Auto

 

restart

 

•Auto

 

changeover

 

•Built

in

 

low

 

ambient

 

standard,

 

down

 

to

 

14°F

 

(cooling

 

mode)

 

•Jet

 

cool/Jet

 

heat

 

•Plasma

 

air

 

purifying

 

system

 

•Self

cleaning

 

indoor

 

coil

 

•Sleep

 

mode

 

•Ultra

 

quiet

 

opera on

 

•Chaos

 

wind

          

 

•Condensate

 

Sensor

 

Connection

 

•Energy

 

saving

 

•Inverter

 

(variable

 

speed

 

compressor)

Dry

 

Contact

 

for

 

third

 

party

 

thermostat

 ‐ 

PQDSBNGCM1

AWG

 ‐ 

American

 

Wire

 

Gage

Reviews: