Performance:
Capacity
(Btu/h)
18,200
SEER
20.5
EER
12.6
Cooling:
Heating:
Capacity
(Btu/h)
22,000
HSPF
9.7
Cooling
Nominal
Test
Conditions:
Heating
Nominal
Test
Conditions:
Indoor:
80°F
DB/67°F
WB
Indoor:
70°F
DB/60°F
WB
Outdoor: 95°F
DB/75°F
WB
Outdoor: 47°F
DB/43°F
WB
Electrical:
MCA
(A)
19
MOP
(A)
30
Fan
Motor
(A)
0.75
Outdoor
Unit:
Cooling
Rated
Amps
(A)
17.0
Heating
Rated
Amps
(A)
17.0
Indoor
Unit:
Cooling
Power
Input
(kW)
1.44
Heating
Power
Input
(kW)
1.76
Piping:
Liquid
Line
(in,
OD)
3/8
Additional
Refrigerant
(oz/ft)
0.38
Max
Elevation
(ft)
49
Piping
Length
(no
add'l
refrigerant,
ft)
25
Power
Supply
(V¹/Hz/Ø)
208
‐
230/60/1
Max
Pipe
Length
(ft)²
98
Compressor
(A)
14.6
Vapor
Line
(in,
OD)
5/8
Features:
Operating
Range:
Outdoor
Unit:
Indoor
Unit:
Unit
Data:
Refrigerant
Type
R410A
Refrigerant
Charge
(lbs)
3.97
Fan:
Standard
Features:
•Limited
Five
Year
Compressor
Warranty
•Limited
Three
Year
Func onal
Parts
Warranty
Notes:
1.Acceptable
opera ng
voltage:
187V
‐
253V.
2.Piping
lengths
are
equivalent.
3.Sound
Pressure
levels
are
tested
in
an
anechoic
chamber
under
ISO
Standard
1996.
4.All
communica on
cable
to
be
minimum
18
AWG,
2
‐
conductor,
stranded,
shielded
and
must
comply
with
applicable
local
and
national
code.
5.See
Engineering
Manual
for
sensible
and
latent
capaci es.
6.Power
wiring
cable
size
must
comply
with
the
applicable
local
and
na onal
code.
7.The
indoor
unit
comes
with
a
dry
helium
charge.
8.This
data
is
rated
0
above
sea
level,
with
24.6
of
refrigerant
line
and
a
0
level
di
ff
erence
between
outdoor
and
indoor
units.
9.Must follow installa on instruc ons in the applicable LG installa on manual.
ODU
Type
Propeller
IDU
Type
Cross
Flow
Motor/Drive
Brushless
Digitally
Controlled/Direct
Dehumidification
(pts/hr)
5.5
Refrigerant
Control
EEV
Heat
Exchanger
Coating
GoldFin™
ODU
Net
Unit
Weight
(lbs)
133
ODU
Shipping
Weight
(lbs)
142
IDU
Net
Unit
Weight
38
IDU
Shipping
Weight
(lbs)
42
Fan
Speeds
(Fan/Cooling/Heating)
5/6/6
Quantity
(ODU
+
IDU)
1
+
1
IDU
Max
Air
Flow
H/M/L
(CFM)
600/510/420
ODU
Max
Air
Flow
Rate
(CFM)
2,119
Communication
Cable
(No
x
AWG)
⁴
4
x
18
Cooling
(°F
DB)
14
‐
118
Heating
(°F
DB)
5
‐
75
Cooling
(°F
DB)
64
‐
90
Heating
(°F
DB)
61
‐
86
ODU
Sound
Pressure
Max
(±3
dB(A))³
53
IDU
Sound
Pressure
(H/M/L)
(±3
dB(A))³
45/40/35
Power
Supply
(V¹/Hz/Ø)
208
‐
230/60/1
Optional
Accessories
(sold
separately):
7
‐
Day
Programmable
Controller
(Black)
‐
PQRCVSL0
7
‐
Day
Programmable
Controller
(White)
‐
PQRCVSL0QW
Indoor
Unit
(IDU)
‐
LAN180HSV2
Outdoor
Unit
(ODU)
‐
LAU180HSV2
PI485
‐
PMNFP14A0
SEER
‐
Seasonal
Energy
Efficiency
Ratio
EER
‐
Energy
Efficiency
Ratio
HSPF
‐
Heating
Seasonal
Performance
Factor
MOP
‐
Maximum
Overcurrent
Protection MCA
‐
Minimum
Circuit
Ampacity
•4
‐
Way
auto
swing
•24
‐
Hour
on/o
ff
mer
•Auto
restart
•Auto
changeover
•Built
‐
in
low
ambient
standard,
down
to
14°F
(cooling
mode)
•Jet
cool/Jet
heat
•Plasma
air
purifying
system
•Self
‐
cleaning
indoor
coil
•Sleep
mode
•Ultra
quiet
opera on
•Chaos
wind
•Condensate
Sensor
Connection
•Energy
saving
•Inverter
(variable
speed
compressor)
Dry
Contact
for
third
party
thermostat
‐
PQDSBNGCM1
AWG
‐
American
Wire
Gage