background image

www.lg.com

Copyright © 2021 LG Electronics Inc. All Rights Reserved

MOT Registration 

No.: IMKG.46.01.2021

H05TN4

AIR CONDITIONER

TYPE: WALL MOUNTED

Read this owner's manual thoroughly before operating the 

appliance and keep it handy for reference at all times.

OWNER’S MANUAL

EN ENGLISH

ID BAHASA INDONESIA

Summary of Contents for H05TN4

Page 1: ...Rights Reserved MOT Registration No IMKG 46 01 2021 H05TN4 AIR CONDITIONER TYPE WALL MOUNTED Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times OWNER S MANUAL EN ENGLISH ID BAHASA INDONESIA ...

Page 2: ...T FUNCTION 13 Auto Restart Function 13 Emergency Function 13 REMOTE CONTROLLER 14 Using Wireless Remote Control 14 Replacement of Batteries 15 OPERATING INSTRUCTIONS 16 Cooling Mode 16 Dry Mode 16 Fan Mode Not Fan Button 17 Auto Mode 17 Display Function Indoor Display 18 Eco Function 18 Turbo Function 19 Sleep Function 19 Timer Function 20 PROTECTION 21 MAINTENANCE 22 Antidust Filters 22 Cleaning ...

Page 3: ...ause serious injury or death CAUTION This indicates that the failure to follow the instructions can cause the minor injury or damage to the product The following symbols are displayed on indoor and outdoor units This symbol indicates that this appliance uses a flammable refrigerant If the refrigerant is leaked and exposure to an external ignition source there is a risk of fire This symbol indicate...

Page 4: ...r mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Installation Do not install the air conditioner on an unstable surface or in a place where there is danger of it falling Contact an a...

Page 5: ...d tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals Improper or loose connections can cause heat generation or fire Install dedicated electric outlet and circuit breaker before using the air conditioner Do not connect the ground wire to a gas pipe a lightning rod or a telephone ground wire Keep any required ventilation opening...

Page 6: ...rgents may cause corrosion or damage to the unit Be sure to ventilate sufficiently when the air conditioner and a heating appliance such as a heater are used simultaneously Do not block the inlet or outlet of air flow Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operating Make sure that the power cable is neither dirty loose nor broken Never tou...

Page 7: ... a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the superv...

Page 8: ...erly grounded have the power outlet and circuit checked by a qualified electrician The refrigerant and insulation blowing gas used in the appliance require special disposal procedures Consult a service agent or a similarly qualified person before disposing of them If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to avoid...

Page 9: ...installation or repair Transport the air conditioner with two or more people or use a forklift Install the outdoor unit such that it is protected from direct sunlight Do not place the indoor unit in a place where it is directly exposed to sunlight via the windows Safely dispose of packing materials such as screws nails or batteries using proper packaging after installation or repair Install the ai...

Page 10: ...als or plants to the cold or hot wind from the air conditioner for extended periods of time If the leaking battery fluid has been swallowed rinse the inside of the mouth thoroughly and consult a doctor Do not drink the water drained from the air conditioner Do not use the product for special purposes such as preserving foods works of art and etc It is an air conditioner for consumer purposes not a...

Page 11: ...tdoor unit rating label c Optional filter if installed o Terminal block cover d LED Display p Gas valve e Signal receiver q Liquid valve f Terminal block cover g Ionizer generator if installed h Deflectors i Emergency button j Indoor unit rating label Stick position optional k Airflow direction louver l Remote controller NOTE The above figures are only intended to be a simple diagram of the applia...

Page 12: ...INDOOR UNIT DISPLAY Display No Led Function 1 Temperature display if present Error code Lights up during timer operation when the air conditioner is operational Displays the malfunction code when fault occurs ...

Page 13: ... from the unit Emergency Function If the remote controller fails to work or maintenance necessary proceed as follows Open and lift the front panel up to an angleto reach the emergency button 1 One press of the emergency button one beep will lead to the forced COOLING operation 2 Two press of the emergency button within 3 seconds two beeps will lead to the forced HEATING operation 3 To switch off t...

Page 14: ... E Symbols Meaning AUTO Mode Auto function indicator COOL Mode Cooling indicator DRY Mode Dry indicator FAN Mode Fan indicator ECO ECO function indicator TIMER Timer indicator Temperature indicator Flashing Fan speed indicator Auto low low mid mid high Mute indicator SUPER indicator Flap swing angle indicator Deflector swing angle indicator Optional SLEEP TIMER DISPLAY Optional functions indicator...

Page 15: ...or special treatment is necessary NOTE Child lock Press and together to active Display ON OFF Long press ECO button Please remove batteries to avoid leakage damage when not using for a long time WARNING 1 Direct the remote controller toward the air conditioner 2 Check that there are no objects between the remote control and the signal receptor in the indoor unit 3 Never leave the remote controller...

Page 16: ... the button or at a temperature lower than that of the room To optimize the function of the air conditioner adjust the temperature a the speed b and the direction of the air flow c by pressing the button indicated OPTION ECO TURBO MODE FAN a c b Dry Mode DRY This function reduces the humidity of the air to make the room more comfortable To set the DRY mode press MODE until DRY appears in the displ...

Page 17: ...ppears on the display OPTION ECO TURBO MODE FAN Auto Mode AUTO Automatic mode To activate the AUTO mode of operation press the MODE button on the remote controller until the symbol AUTO appears on the display In AUTO mode the air conditioner will run automatically according to the room temperature OPTION ECO TURBO MODE FAN ...

Page 18: ...nel and DISPLAY appears on the remote controller display Do it again to switch on the LED display OPTION ECO TURBO MODE FAN Eco Function ECO The air conditioner works in economic mode Only in Heating or Cooling model press ECO button and symbol ECO will appear on the display the air conditioner will work in energy saving process To cancel this function pressing the MODE to switch other mode or pre...

Page 19: ...ou select TURBO feature it will use the highest fan setting to blow strong airflow OPTION ECO TURBO MODE FAN Sleep Function SLEEP Press OPTION at the fist time select the SLEEP by pressing the button or until symbol SLEEP is flashing Press OPTION again to activate the SLEEP function and SLEEP appears on the display Do it again to deactivate this function After 10 hours running in sleep mode the ai...

Page 20: ...ase or decrease at half hour intervals the symbols h and TIMER both are flashing Press OPTION or waiting for 5 seconds without any operation to confirm the timer the pre setting timer like and symbol TIMER will be on the display To cancel the timer if TIMER is on Press OPTION or waiting for 5 seconds without any operation to cancel the timer 4 A sample for the Timer on as Figure1 Timer off as Figu...

Page 21: ...T3 Climate Condition Models No Mode Ambient temperature 1 Cooling Outdoor temperature is over 52 C Room temperature is below 21 C 2 Dry Room temperature is below 18 C WARNING The unit does not operate immediately if it is turned on after being turned off or after changing the mode during operation This is a normal self protection action you need wait for about 3 minutes The capacity and efficiency...

Page 22: ...el of the unit and life it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with the water not higher than 40 C and neutral soap Never use aggressive solvents or detergents 3 If the outdoor unit is clogged remove the leaves and the waste and remove the dust with air jet or a bit of water End of Season Maintenance 1 Dis...

Page 23: ... made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem Insufficient airflow either hot or cold Inappropriate temperature setting Air inlet or outlet of indoor or outdoor unit has been blocked Air filter is blocked Fan speed set at minimum Other sources of heat in the room No refrigerant The appliance does not respond to commands Re...

Page 24: ...he display on the indoor unit shown the following error codes RUN lamp Description of the trouble Flashes once The fault of indoor temperature sensor Flashes twice The fault of indoor pipe temperature sensor Flashes 6 times Malfunction of indoor fan motor ...

Page 25: ...Memo ...

Page 26: ...Memo ...

Page 27: ...Memo ...

Page 28: ...Memo ...

Page 29: ...PT LG Electronics Indonesia Gedung Gandaria 8 Office Tower Lt 29 BC 31 ABCD Jl Sultan Iskandar Muda Kebayoran Lama Utara Kebayoran Lama Jakarta Selatan DKI Jakarta 12240 Indonesia ...

Reviews: