5-17
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Normal
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Check high vol-
tage transformer
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Normal
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Normal
Check high vol-
tage diode.
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Summary of Contents for GoldStar MS-133SE
Page 30: ...6 2 13213A 13552A 13536A 13581A 14026A 14970A 13720D 13352A 15006A DOOR PARTS ...
Page 31: ...6 3 26638A 23572A 268711 24781M WTP018 WTT028 24510L 250201 24970A CONTROL PANEL PARTS ...
Page 33: ...6 5 43501A 466003 466002 43500A 466001 WSZ002 LARCH BOARD PARTS ...
Page 36: ...6 8 WSZ002 WTT030 647781 647781 63302L 56170D 63302R 13806F WTT028 WTT021 BASE PLATE PARTS ...
Page 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 38: ...8 2 PRINTED CIRCUIT BOARD ...
Page 39: ...MIC SER MODEL CAUTION BEFORE SERV READ THE SA March 1999 P NO 3828W5S1100 Printed in Korea ...