COMPONENTS
TEST PROCEDURE
RESULTS
5-11
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
POWER
LEVEL
1
4 sec
18 sec
2
6 sec
16 sec
3
8 sec
14 sec
4
10 sec
12 sec
5
12 sec
10 sec
6
14 sec
8 sec
7
16 sec
6 sec
8
18 sec
4 sec
9
20 sec
2 sec
10
22 sec
0 sec
Normal:
A: Approx. 85 ~ 100 ohm.
B: Approx. 10 ~ 25 ohm.
Abnormal: Infinite or several
ohm.
Normal: Approx. 100 ~ 150 ohm.
Abnormal: Infinite or several
ohm.
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Relay 2
A
B
Summary of Contents for GoldStar MS-133SE
Page 30: ...6 2 13213A 13552A 13536A 13581A 14026A 14970A 13720D 13352A 15006A DOOR PARTS ...
Page 31: ...6 3 26638A 23572A 268711 24781M WTP018 WTT028 24510L 250201 24970A CONTROL PANEL PARTS ...
Page 33: ...6 5 43501A 466003 466002 43500A 466001 WSZ002 LARCH BOARD PARTS ...
Page 36: ...6 8 WSZ002 WTT030 647781 647781 63302L 56170D 63302R 13806F WTT028 WTT021 BASE PLATE PARTS ...
Page 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 38: ...8 2 PRINTED CIRCUIT BOARD ...
Page 39: ...MIC SER MODEL CAUTION BEFORE SERV READ THE SA March 1999 P NO 3828W5S1100 Printed in Korea ...