• Microwave power output measurement is made with
the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000±5) g of potable water.
• The water is contained in a cylindrical borosilicate glass
vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190mm.
• The oven and the empty vessel are at ambient
temperature prior to the start of the test.
• The initial temperature (T1) of the water is (10±2)°C It
is measured immediately before the water is added to
the vessel. After addition of the water to the vessel,
the load is immediately placed on the center of the
turntable which is in the lowest position and the
microwave power switched on.
• The time T for the temperature of the water to rise by a
value
∆
T of (10±2)°K is measured, where T is the time
in seconds and
∆
T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.
• The microwave power output P in watts is calculated
from the following formula :
4187 x (
∆
T)
T
is measured while the microwave generator is
operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)
• The water is stirred to equalize temperature throughout
the vessel, prior to measuring the final water
temperature.
• Stirring devices and measuring instruments are
selected in order to minimize addition or removal of
heat.
A. OUTER CASE REMOVAL
1) Disconnect the power supply cord from the outlet.
2) Remove the screws from the rear of the case.
The outer case must be moved backward to be lifted
off.
B. POWER SUPPLY CORD
1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of
the ground terminal.
C. CONTROL PANEL ASSEMBLY
1) Open the door.
2) Disconnect the leadwire from RELAY(RY2) of the
PCB SUB ASS’Y.
3) Lift up and pull out control panel assembly carefully
from the cavity.
4) Disconnect the leadwire from connector(CN1) of the
PCB SUB ASS’Y.
CAUTION: DISCHARGE THE HIGH VOLTAGE
CAPACITOR BEFORE SERVICING
(refer to page 2-1)
5-3
WATER LOAD
TURNTABLE
securing screw
ground screw
MEASUREMENT OF MICROWAVE POWER OUTPUT
P =
Remove the screw
Lift up and pull out control panel
DISASSEMBLY AND ADJUSTMENT
Summary of Contents for GoldStar MS-133SE
Page 30: ...6 2 13213A 13552A 13536A 13581A 14026A 14970A 13720D 13352A 15006A DOOR PARTS ...
Page 31: ...6 3 26638A 23572A 268711 24781M WTP018 WTT028 24510L 250201 24970A CONTROL PANEL PARTS ...
Page 33: ...6 5 43501A 466003 466002 43500A 466001 WSZ002 LARCH BOARD PARTS ...
Page 36: ...6 8 WSZ002 WTT030 647781 647781 63302L 56170D 63302R 13806F WTT028 WTT021 BASE PLATE PARTS ...
Page 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 38: ...8 2 PRINTED CIRCUIT BOARD ...
Page 39: ...MIC SER MODEL CAUTION BEFORE SERV READ THE SA March 1999 P NO 3828W5S1100 Printed in Korea ...