Installation
Cord, clip
Wiring
Connection
1 ,220 240V , 50Hz
WARNING: Make sure that the screws of the terminal are free from
looseness.
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR
or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer
or its service agent.
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
CAUTION
m
m
2.5
20m
m
L
Y
/
N
G
m
0.75m
20m
m
L
Y
/
N
G
Ø
Open the control box cover and connect the remote control cord and Indoor power wires.
Wired Remote
Controller Cord
(there is no need
in case of Wireless
Remote Controller)
Control box cover
(On which the Electric
Connection cord Wiring
Connection is put)
Connection
cord between the
indoor unit and
the outdoor unit
Installation
Manual
13
1(L) 2(N)
Connected to indoor unit
1(L) 2(N)
1(L) 2(N)
3
outdoor unit
Main
Terminal Block Indoor
1(L) 2(N)
Connected to indoor unit
outdoor unit
Main
(R) (S) (T) (N ) 1(L) 2(N) 4 5
3 ,380 415V ,50HZ
Ø
3
AT-C186PLE1
AT-C186PLE0
AT-C186PLE0
AT-C246PLE0
AT-C308PLE0
AT-C368NLE0
AT-C488MLE0
AT-C548MLE0
2.5 mm
2
Terminal Block Indoor
3
AT-C186PLE1
AT-C246PLE0
AT-C308PLE0
AT-C368NLE0
AT-C488MLE0
AT-C548MLE0
0.75 mm
2
3