10. Installation
Indoor unit
24
_
ARTCOOL (Mirror)
Indoor Units
Ø65
133
95
Right rear piping
Left rear piping
Installation Plate
Place a level on raised tab
Unit Outline
217
175
442
442
Ø65
Ø65
Ø65
SB chassis
SC chassis
Ø65
Ø65
Ø65
Ø65
69
56
Right rear piping
Left rear piping
Installation Plate
Installation Plate
Installation Plate
Measuring Tape
Measuring Tape
Hanger
Place a level on raised tab
Unit Outline
207
105
460
570
Ø65
More than 200
More than
100
More than 2300
More than
100
(Unit : mm)
Ø65
Installation Plate
Installation Plate
Chassis
Hook
Type "A" Screws
Ø65
Ø65
Installation Plate
The lower left and the right side of Installation Plate
CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.
10.1 Selection of the best location
•
There should not be any heat or steam near the unit.
•
Select a place where there are no obstacles around of the
unit.
•
Make sure that condensation drainage can be conveniently
routed away.
•
Do not install near a doorway.
•
Ensure that the interval between a wall and the left (or right) of
the unit is more than 100mm. The unit should be installed as
high as possible on the wall, allowing a minimum of 200mm
from ceiling.
•
Use a metal detector to locate studs to prevent unnecessary
damage to the wall.
Fixing Installation Plate
The wall you select should be strong and solid enough to
prevent vibration
• Mount the installation plate on the wall with type "A"
screws. If mounting the unit on a concrete wall, use
anchor bolts.
- Mount the installation plate horizontally by aligning the
centerline using Horizontal meter .
• Measure the wall and mark the centerline. It is also
important to use caution concerning the location of the
installation plate. Routing of the wiring to power outlets
is through the walls typically. Drilling the hole through
the wall for piping connections must be done safely.