Original instruction 

This manual is the simplified version of original manual. 

You can obtain the original manual from www.lg.com.

Please read this installation manual completely before installing the product.

Installation work must be performed in accordance with the national wiring standards 

by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

ENGLISH

BAHASA INDONESIA

*MFL63260122*

AMNQ09GSJA0  AMNQ12GSJA0  AMNQ18GSKA0  AMNQ24GSKA0
AMNQ09GSJB0  AMNQ12GSJB0  AMNQ18GSKB0  AMNQ24GSKB0
AMNQ09GL1A0  AMNQ12GL2A0  AMNQ18GL2A0  AMNQ24GL3A0
AMNQ09GTUA0  AMNQ12GTUA0  AMNQ18GTTA0  AMNQ24GTTA0

IMKG.1077.05.2021

Summary of Contents for AMNQ09GL1A0

Page 1: ...anual completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly ENGLISH BAHASA INDONESIA MFL63260122 AMNQ09GSJA0 AMNQ12GSJA0 AMNQ18GSKA0 AMNQ24GSKA0 AMNQ09GSJB0 AMNQ12GSJB0 AMNQ18GSKB0 AMNQ24GSKB0 AMNQ09GL1A0 AMNQ12...

Page 2: ...vels this cannot be used reliably to determine whether or not further precautions are required Factor that influence the actual level of exposure of the workforce include the characteristics of the work room and the other sources of noise i e the number of equipment and other adjacent processes and the length of time for which an operator exposed to the noise Also the permissible exposure level ca...

Page 3: ...ualified electrician or an Authorized Service Center Do not disassemble or repair the product by yourself There is risk of fire or electric shock WARNING This indicates that the failure to follow the instructions can cause serious injury or death CAUTION This indicates that the failure to follow the instructions can cause the minor injury or damage to the product This symbol is displayed to indica...

Page 4: ...arged capacitor can cause electrical shock When installing the unit use the installation kit provided with the product Otherwise the unit may fall and cause severe injury Indoor outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals Improper or loose connections can cause heat generation o...

Page 5: ...t is not to be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit This could result in personal injury and product damage Take care to ensure that power cable could not be pulled out or damaged during operation The...

Page 6: ... Do not use the product for special purposes such as preserving foods works of art etc It is a consumer air conditioner not a precision refrigeration system There is risk of damage or loss of property Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules Appliance shall be disconnected from its power source during service and when replacing parts Do n...

Page 7: ...y fluid from a leak wash out the inside of your mouth thoroughly and then consult a doctor Failure to do so may result in serious health complications Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open Moisture may condense and wet or damage furniture Do not expose your skin or kids or plants to the cool or hot air draft This could...

Page 8: ... such as areas with ceiling texture More than A More than B More than C More than B Unit mm Unit mm Ceiling Ceiling Board Ceiling Board H 1 000 or more 500 or more 300 or less At least 1 800 H or less 10 or more 500 or more Type A B C Wall mounted 200 100 2 300 ART COOL 200 500 1 500 ART COOL Mirror 200 100 2 300 Console 300 300 250 or less More than 300 More than 300 More than 300 More than 200 M...

Page 9: ... 29 4 2 151 36 4 4 166 12 Floor location m kg Amin m2 4 6 181 56 4 8 197 70 5 214 51 5 2 232 02 5 4 250 21 5 6 269 09 5 8 288 65 6 308 90 6 2 329 84 6 4 351 46 6 6 373 77 6 8 396 76 7 420 45 7 2 444 81 7 4 469 87 7 6 495 61 7 8 522 04 Wall mounted m kg Amin m2 1 224 1 224 1 43 1 4 1 87 1 6 2 44 1 8 3 09 2 3 81 2 2 4 61 2 4 5 49 2 6 6 44 2 8 7 47 3 8 58 3 2 9 76 3 4 11 02 3 6 12 36 3 8 13 77 4 15 2...

Page 10: ...oller You can operate the air conditioner more conveniently with the remote controller You will find the buttons for the additional functions under the cover of the remote control 1 L 2 N 3 Connected to outdoor unit or B D unit The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications Rubber insulation type H05RN F approved by HAR or SAA 20 ...

Page 11: ...he following settings for 2 to 3 hours Type of operation Fan operation mode Refer to page Fan Mode This will dry out the internal mechanisms 2 Turn off the breaker 3 Remove the batteries from the Remote Controller Helpful information The air filters and your electric bill If the air filters become clogged with dust the cooling capacity will drop and 6 of the electricity used to operate the air con...

Page 12: ...ccurs when the airflow from the air conditioner cools the warm room air Air conditioner does not operate for about 3 minutes when restart This is the protector of the mechanism Wait about three minutes and operation will begin Does not cool or heat effectively Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned...

Page 13: ...13 ENGLISH ...

Page 14: ...14 ENGLISH ...

Page 15: ...AMNQ12GTUA0 AMNQ18GTTA0 AMNQ24GTTA0 Hak cipta 2021 LG Elektronik Semua hak cipta di lindungi Silakan baca buku panduan pemasangan ini seluruhnya sebelum memasang produk Pekerjaan pemasangan harus dilakukan sesuai dengan standar pengabelan nasional oleh petugas resmi saja Silakan simpan buku panduan pemasangan ini untuk referensi di masa mendatang setelah membaca seluruhnya www lg com BUKU PANDUAN ...

Page 16: ...apat diandalkan untuk menentukan apakah pencegahan lebih lanjut diperlukan atau tidak Faktor yang memengaruhi tingkat paparan tenaga kerja yang sebenarnya termasuk karakteristik ruang kerja dan sumber kebisingan lainnya misalnya jumlah peralatan dan proses lain yang berdekatan dan lama waktu operator terkena kebisingan tersebut Tingkat paparan yang diperbolehkan juga dapat berbeda dari satu negara...

Page 17: ...lukan Gunakan pemutus arus listrik dan sekring dengan kapasitas yang benar Ada risiko kebakaran atau sengatan listrik PERINGATAN Ini menunjukkan bahwa kegagalan mengikuti petunjuk dapat mengakibatkan cedera serius bahkan kematian PERHATIAN Ini menunjukkan bahwa kegagalan mengikuti petunjuk dapat mengakibatkan cedera ringan atau kerusakan produk Simbol yang ditampilkan menunjukkan masalah dan pengo...

Page 18: ... tegangan memasok listrik bertegangan tinggi ke komponen listrik Pastikan untuk mengosongkan kapasitor sepenuhnya sebelum melakukan pekerjaan perbaikan Kapasitor yang bermuatan dapat menyebabkan sengatan listrik Saat memasang unit gunakan kit pemasangan yang disediakan bersama produk Jika tidak unit dapat jatuh dan menyebabkan cedera serius Sambungan kabel dalam ruangan luar ruangan harus tersambu...

Page 19: ...operasikan bersamaan dengan kompor atau elemen pemanas dsb Kekurangan oksigen dapat terjadi dan membahayakan kesehatan Anda Saat produk tidak digunakan untuk waktu yang lama cabut steker atau matikan pemutus arus listrik Ada risiko kerusakan atau kegagalan produk atau pengoperasian yang tidak diinginkan Berhati hatilah untuk memastikan tidak ada orang terutama anak anak yang dapat menginjak atau j...

Page 20: ...berpotensi ledakan Pengoperasian Jangan menggunakan produk untuk tujuan khusus seperti mengawetkan makanan karya seni dll Ini adalah pendingin ruangan konsumen bukan sistem pendinginan presisi Ada risiko kerusakan atau hilangnya properti Sarana pemutusan harus disertakan dalam pemasangan kabel sesuai dengan peraturan pengabelan Alat harus dicabut dari sumber dayanya selama servis dan saat menggant...

Page 21: ...ebabkan komplikasi kesehatan yang serius Jangan biarkan pendingin ruangan menyala untuk waktu yang lama saat kelembapannya sangat tinggi dan pintu atau jendela dibiarkan terbuka Udara yang lembap dapat mengembun dan membasahi atau merusak perabotan Jangan biarkan kulit Anda atau anak anak atau tanaman terkena aliran udara dingin atau panas Hal ini dapat membahayakan kesehatan Anda Jangan meminum a...

Page 22: ...Lebih dari A Lebih dari B Lebih dari C Lebih dari B Satuan mm Satuan mm Langit langit Papan Langit Langit Papan Langit Langit H 1 000 atau lebih 500 atau lebih 300 atau kurang Setidaknya 1 800 H atau kurang 10 atau lebih 500 atau lebih Tipe A B C Dipasang di dinding 200 100 2 300 ART COOL 200 500 1 500 ART COOL Cermin 200 100 2 300 Konsol 300 300 250 atau kurang Rangka H TU TT 3 300 TQ TR TP 3 600...

Page 23: ...si lantai m kg Amin m2 1 224 1 224 12 9 1 4 16 82 1 6 21 97 1 8 27 80 2 34 32 2 2 41 53 2 4 49 42 2 6 58 00 2 8 67 27 3 77 22 3 2 87 86 3 4 99 19 3 6 111 20 3 8 123 90 4 137 29 4 2 151 36 4 4 166 12 Lokasi lantai m kg Amin m2 4 6 181 56 4 8 197 70 5 214 51 5 2 232 02 5 4 250 21 5 6 269 09 5 8 288 65 6 308 90 6 2 329 84 6 4 351 46 6 6 373 77 6 8 396 76 7 420 45 7 2 444 81 7 4 469 87 7 6 495 61 7 8 ...

Page 24: ... pengendali jarak jauh Anda dapat mengoperasikan pendingin ruangan lebih nyaman dengan pengendali jarak jauh Anda akan menemukan tombol untuk fungsi tambahan di bawah penutup pengendali jarak jauh 1 L 2 N 3 Tersambung ke unit luar ruangan atau B D unit Kabel penyambung yang tersambung ke unit dalam ruangan dan unit luar ruangan harus mematuhi spesifikasi berikut ini Penyekat karet tipe H05RN F dis...

Page 25: ...angan dengan pengaturan berikut selama 2 sampai 3 jam Jenis operasi Mode operasi kipas Lihat halaman Mode Kipas Ini akan mengeringkan mekanisme internal 2 Mematikan pemutus arus listrik 3 Lepaskan baterai dari Pengendali Jarak Jauh Informasi yang bermanfaat Filter udara dan tagihan listrik Anda Jika filter udara tersumbat oleh debu kapasitas pendinginan akan menurun dan 6 listrik yang digunakan un...

Page 26: ...n terjadi saat aliran udara dari pendingin ruangan mendinginkan udara ruangan yang hangat Pendingin ruangan tidak beroperasi selama sekitar 3 menit saat dinyalakan kembali Ini adalah pelindung mekanisme Tunggu sekitar tiga menit dan operasi akan dimulai Tidak menyejukkan atau memanaskan dengan efektif Apakah filter udara kotor Lihat petunjuk membersihkan filter udara Ruangan mungkin terlalu panas ...

Page 27: ...13 BAHASA INDONESIA ...

Page 28: ...PT LG Electronics Indonesia Gandaria 8 Office Tower Lt 29 BC 31 ABCD Jl Sultan Iskandar Muda Kebayoran Lama Utara Kebayoran Lama Jakarta Selatan DKI Jakarta Raya Indonesia ...