background image

ENGLISH

FRANÇAIS

P/NO : MFL68061208

INSTALLATION MANUAL

AIR

CONDITIONER

www.lg.com

Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring 
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it 
thoroughly.

Summary of Contents for ABUQ18GM1T0

Page 1: ...m Please read this installation manual completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly ...

Page 2: ...uality may deteriorate if the air condition er is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weaken the cooling dehumidifying functions For your records Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes Write the model number and the serial number her...

Page 3: ...it may cause a fire electrical shock explosion or injury Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely it could result in a fire or electric shock due to dust water etc Always install an earth leakage circuit breaker and a dedi...

Page 4: ...lectri cal shock Do not open the suction inlet of the indoor outdoor unit during operation Otherwise it may electrical shock and failure Do not allow water to run into electrical parts Otherwise it may cause the failure of machine or electrical shock Do not touch the power cable with wet hands It may cause electric shock and damage Never touch the metal parts of the unit when removing the filter T...

Page 5: ...t Keep level parallel in installing the product Otherwise it may cause vibration or water leak age Operation Avoid excessive cooling and perform ventilation sometimes Otherwise it may do harm to your health Use a soft cloth to clean Do not use wax thinner or a strong detergent The appearance of the air conditioner may deteriorate change color or develop surface flaws Do not use an appliance for sp...

Page 6: ... Indoor Unit and Outdoor Unit 13 Connecting the cable to Outdoor Unit 14 CONNECTING PIPES 14 Preparation of Piping 15 Connecting the pipes to the Outdoor unit 16 Forming the Piping 17 LEAKAGE TEST AND EVACUATION 17 Preparation 17 Leakage test 18 Evacuation 19 TEST RUNNING 21 FUNCTION 21 Forced Cooling Operation 22 SELF DIAGNOSIS FUNC TION 22 Error Indicator Outdoor 24 INSTALLATION GUIDE AT THE SEA...

Page 7: ...rom the air conditioner do not disturb neighbors More than 300 mm Fence or obstacles More than 700 mm More than 600 mm More than More than 300mm 300mm More than 300 mm Sunroof Unit mm Installation Places MODEL Pipe Size Length A m Elevation B m Additional Refrigerant g m Gas Liquid Standard Max Standard Max ABUQ18GM1T0 Ø12 7 1 2 Ø6 35 1 4 10 30 5 20 20 ABUQ24GM1T0 Ø15 88 5 8 Ø9 52 3 8 10 30 5 20 2...

Page 8: ...ased on standard length and maximum allowance length is on the basis of reliability Improper refrigerant charge may result in abnormal cycle CAUTION If installed tube is shorter than Standard length additional charging is not necessary Additional Refrigerant Max Length Standard Length x Additional refrigerant g ...

Page 9: ...setting Open the Side panel or Top Cover of outdoor unit Set the SW01N ABUQ18GM1T0 ABUQ24GM1T0 ABUQ30GM1T0 ABUQ36GM3T0 ABUQ48LM3T0 ABUQ54LM3T0 ABUQ18GM1T0 ABUQ24GM1T0 ABUQ30GM1T0 ABUQ36GM3T0 ABUQ48LM3T0 ABUQ54LM3T0 SW01N 6 7 8 9 10 6 7 8 9 10 Step 1 Step 2 Step 1 Step 2 DIP_SW DIP SW01D 6 7 8 9 10 ...

Page 10: ...the air condi tioner Use a recognized ELCB Electric Leakage Circuit Breaker between the power source and the unit A disconnection device to ade quately disconnect all supply lines must be fitted Model of circuit breaker recommended by authorized personnel only Outdoor Indoor Main power source Switch box ELCB WIRING CONNECTION Model Phase Ø ELCB ABUQ18GM1T0 1 25A ABUQ24GM1T0 1 25A ABUQ30GM1T0 1 30A...

Page 11: ... or HD 22 4 S4 This equipment shall be provided with a cable set complying with the national regulation If the supply cable is damaged it must be replaced by a special cable or assembly availible from the manufacturer of its service agent When the connection line between the indoor unit and out dooor unit is over 40 m connect the telecommunication line and power line separately CAUTION GN YL 20 mm...

Page 12: ...ow For wiring use the designated power wire and connect firmly then secure to prevent outside pressure being exerted on the terminal block Use an appropriate screwdriver for tightening the terinal screws A screwdriver with a small head will strip the head and make proper tighterning impossible Over tightening the terminal screws may break them Round pressure terminal Power wire Connect same thickn...

Page 13: ...nal Power cord terminal Cord clamp Make sure the rubber bushes are properly used in knock out holes after connecting main power The circuit diagram is not subject to change without notice Be sure to connect wires according to the wiring diagram Connect the wires firmly so that not to be pulled out easily Connect the wires according to color codes by referring the wiring diagram The Power cable con...

Page 14: ...s attached to indoor and outdoor unit then put them on pipe tube having completed burr removal not possible to put them on after flaring work Flaring work Carry out flaring work using flaring tool as shown below Firmly hold copper pipe in a bar in the dimension shown in the table below Check Compare the flared work with figure below If flare is noted to be defective cut off the flared section and ...

Page 15: ...ch ensure the direction for tightening follows the arrow on the wrench Torque wrench Contin uous Gas side piping Liquid side piping Drain hose Connecting wire h When tighten the pipe hold the haxago nal body Outside diameter Torque mm inch N m Ø 6 35 1 4 16 2 Ø 9 52 3 8 38 4 Ø 12 7 1 2 55 6 Ø 15 88 5 8 75 7 Ø 19 05 3 4 110 10 Preventing foreign objects from entering Plug the pipe through holes wit...

Page 16: ...d above the Indoor unit perform the following 1 Tape the piping and connecting cable from down to up 2 Secure the taped piping along the exterior wall Form a trap to prevent water entering the room 3 Fix the piping onto the wall by saddle or equivalent Trap is required to prevent water from entering into electrical parts Taping Drain hose Pipings Connecting cable Power supply cord Plastic Plastic ...

Page 17: ...of the cylinder must be higher than its bottom when you pressurize the system Usually the cylinder is used in a vertical standing position Do a leakage test of all joints of the tubing both indoor and outdoor and both gas and liquid side service valves Bubbles indicate a leak Be sure to wipe off the soap with a clean cloth After the system is found to be free of leaks relieve the nitrogen pressure...

Page 18: ...e valve stem of gas side valve counter clockwise to fully open the valve Loosen the charge hose connected to the gas side service port slightly to release the pressure then remove the hose Replace the flare nut and its bonnet on the gas side service port and fasten the flare nut secure ly with an adjustable wrench This process is very important to prevent leakage from the sys tem Indoor unit Outdo...

Page 19: ...r supply Circuit breaker is required Operate the unit for fifteen minutes or more Precautions In Test Running Connection of power supply Evaluation of the performance CAUTION For test run carry out the cooling operation firstly even during heating season If heating operation is carried out firstly it leads to the trouble of compressor Then attention must be paid Carry out the test run more than 5 ...

Page 20: ...ey are all tightly fastened If they are loose it could give rise to burn out of the wires 4 Specification of power source 5 Confirm that electrical capacity is sufficient 6 Be sure that the starting voltage is maintained at more than 90 percent of the rated volt age marked on the name plate 7 Confirm that the cable thickness is as specified in the power sources specification Particularly note the ...

Page 21: ...tch as follow after shutting the power source down Reset the power Red LED and Green LED of PCB lights during work The indoor unit is operated by force If operation is done Red LED will be turned off If operation is not done normally Red LED will blink Close the Liquid valve only after green LED turned off 7 minutes from the start of the machine Then close the gas valve after Green LED on ABUQ18GM...

Page 22: ...ror 21 DC Peack 1 Time 1 Time 1 Time 2 Times 2 Times 2 Times 1 Sec 2 Sec 2 Sec 1 Sec 1 Sec LED01G RED LED02G GREEN ABUQ18GM1T0 ABUQ24GM1T0 ABUQ30GM1T0 ABUQ36GM3T0 ABUQ48LM3T0 ABUQ54LM3T0 SELF DIAGNOSIS FUNCTION SELF DIAGNOSIS FUNCTION 22 ENGLISH ...

Page 23: ...r Th Error Open Short 4times 4times OFF 45 Cond Middle Pipe Th Error Open Short 4times 5times OFF 46 Suction Pipe Th Error Open Short 4times 6times OFF 48 Cond Out Pipe Th Error Open Short 4times 8time OFF 51 Capacity over 5times 1times OFF 53 Communication Error Indoor Outdoor 5times 3times OFF 60 EEPROM Error Outdoor 6times 0 OFF 61 Cond Middle Pipe High 6times 1times OFF 62 Heatsink Error High ...

Page 24: ...wind Windbreak Periodic more than once year clean ing of the dust or salt particles stuck on the heat exchanger by using water Air conditioners should not be installed in areas where corrosive gases such as acid or alkaline gas are produced Do not install the product where it could be exposed to sea wind salty wind directly It can result corrosion on the product Corrosion particularly on the conde...