background image

Color Monitor

USER GUIDE 
MANUEL D'UTILISATION

MODEL : 500LC

Summary of Contents for 500LC

Page 1: ...Color Monitor USER GUIDE MANUEL D UTILISATION MODEL 500LC ...

Page 2: ...rmined by turning the equipment off and on the user is encouraged to try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radi...

Page 3: ...ctric fields magnetic fields static electricity and visual ergonomic requirements Futhermore this model is produced with concern for the environment and contains no harmful substances in any of its components Products with the CE Marking comply with the EMC Directive 89 336 EEC and LOW VOLTAGE Directive 73 23 EEC issued by the Commission of the European Community Compiance with these directives im...

Page 4: ...On Screen Display OSD Control Adjustment A8 Control Panel Function A8 On Screen Display OSD Selection and Adjustment A10 Video Memory Modes Factory Preset Timing Signal Chart A13 Factory Preset modes A13 User Modes A15 Recalling Display Modes A15 Power Management System Power Consumption A16 MPR II Self Diagnostics and DDC Low Radiation Compliance MPR II A17 Self Diagnostics A17 DDC Display Data C...

Page 5: ... The microprocessor based intelligence allows the monitor to operate in each frequency mode with the precision of a fixed frequency monitor The microprocessor based digital controls allow you to adjust conveniently a variety of image controls by using the OSD On Screen Display It supports resolutions up to 1024x768 and has a wide viewing angle of 60 degrees horizontal and 45 degrees vertical The m...

Page 6: ...odel No Serial No Notice All rights reserved Reproduction in any manner in whole or in part is strictly prohibited without the written permission of LG Electronics Inc Trademark Acknowledgments LG is a trademark of LG Electronics Inc IBM is a registered trademark and VGA is a trademark of International Business Machines Corporation WARNING To reduce the risk of fire or electric shock do not expose...

Page 7: ...erloaded AC outlets and extension cords are dangerous So are frayed power cords and broken plugs They may result in a shock or fire hazard Call your service technician for replacement 4 DO NOT OPEN THE MONITOR There are no user serviceable components inside There are Dangerous High Voltages inside even when the power is OFF Contact your dealer if the monitor is not operating properly 5 To avoid pe...

Page 8: ...e Matrix LCD permanently 5 Do not press the LCD screen with your finger for a long time as this may incur some afterimages 6 Some dot defects may appear on the screen like Red Green or Blue spots on the screen However this will have no impact or effect on the monitor performance 7 If possible use the VESA 1024x768 60Hz video mode to obtain the best image quality for your LCD monitor If used under ...

Page 9: ...ly turn the connector upside down and try again When mated tighten the thumbscrews to secure the connection Connect the plug from the AC DC adapter into the connector on the display unit Connect one end of the AC power cord into the AC DC adapter Plug the other end into a properly grounded three prong AC outlet Power ON the PC then the monitor If you see the Check Signal Cable message check the si...

Page 10: ... signal cable to the side of the adapter block with 3 rows Connect the attached adapter block signal cable to the video output on your MAC Connect the plug from the AC DC adapter into the connector on the display unit Connect one end of the AC power cord into the AC DC adapter Plug the other end into a properly grounded three prong AC outlet Power ON the PC then the monitor If you see the Check Si...

Page 11: ...ols Front View Rear View DC Power Connecter D Sub Signal Connecter ID Label Power Indicator Power ON OFF Enter Button Brightness Adjustment Buttons Mode Recall Button OSD Selection Buttons OSD Adjustment Buttons OSD ON OFF Enter Button ...

Page 12: ... this button to start and exit from the On Screen Display OSD OSD Selection Buttons Use these buttons for selecting highlighting an OSD icon to be adjusted OSD Adjustment Buttons Use these buttons for adjusting the level of the selected item Brightness Adjustment Buttons Use these buttons for adjusting the brightness of screen A8 On Screen Display OSD Control Adjustment Control Panel Function B r ...

Page 13: ... user mode this control has no effect Power Indicator This Indicator lights up green when the monitor operates normally If the monitor is in DPM Energy Saving mode stand by suspend power off this indicator color changes to amber Power ON OFF Enter Button This button is used to turn the monitor ON and OFF M o d e R e c a l l S E L E N T N O Y E S Control Panel Function ...

Page 14: ...D J S E L OSD M a x M i n H P o s i t i o n A D J S E L OSD A D J S E L OSD M a x M i n C o n t r a s t M a x M i n A D J S E L OSD C o n t r a s t A D J S E L OSD To move picture image left and right Moves the screen image left Moves the screen image right To adjust the focus of the display This item allows you to remove any horizontal noise and clear or sharpen the image of characters Clock Phas...

Page 15: ...default setting OSD Time OSD Adjust Description Color Select OSD OSD S E L M A I N 9 3 0 0 K 6 5 0 0 K U s e r A D J S E L OSD A D J S E L OSD 9 3 0 0 K 6 5 0 0 K U s e r R G B R e c a l l A D J S E L OSD 5 0 S e c o n d s A D J S E L OSD O S D T i m e To select OSD display duration time 5 100 seconds This item gives access to 2 elements Horizontal position and Vertical position Press the select b...

Page 16: ... I N 1 0 2 4 X 7 6 8 7 5 H z P r e s e t M o d e 1 4 U s e r M o d e 0 I n f o r m a t i o n N E X T M A I N 1 3 1 5 k H z 7 0 H z 2 3 1 5 k H z 7 0 H z 3 3 1 5 k H z 6 0 H z 4 3 5 0 k H z 6 7 H z 5 3 7 9 k H z 7 3 H z 6 3 7 5 k H z 7 5 H z 7 3 5 2 k H z 5 6 H z 8 3 7 9 k H z 6 0 H z P r e s e t M o d e L a n g u a g e S E L M A I N OSD OSD E n g l i s h E N D E F R E S I T U s e r M o d e T h e E...

Page 17: ... pixels 640 720 640 640 640 640 800 A Blanking pixels 160 180 160 224 192 200 224 B Front Porch pixels 16 17 16 64 24 16 24 C Pulse Width pixels 96 108 96 64 40 64 72 D Back Porch pixels 48 55 48 96 128 120 128 F Polarity Frequency Hz 70 70 60 66 67 72 8 75 0 56 25 Total Period lines 449 449 525 525 520 500 625 E Data Period lines 350 400 480 480 480 480 600 A Blanking lines 99 49 45 45 40 20 25 B...

Page 18: ... C Pulse Width pixels 128 120 80 64 136 136 96 D Back Porch pixels 88 64 160 224 160 144 176 F Polarity Frequency Hz 60 3 72 188 75 0 74 55 60 0 70 0 75 0 Total Period lines 628 666 625 667 806 806 800 E Data Period lines 600 600 600 624 768 768 768 A Blanking lines 28 66 25 43 38 38 32 B Front Porch lines 1 37 1 1 3 3 1 C Pulse Width lines 4 6 3 3 6 6 3 D Back Porch lines 23 23 21 39 29 29 28 F R...

Page 19: ...th mode 15 Recalling Display Modes When your monitor detects a mode it has seen before it automatically recalls the image settings you may have made the last time you used that mode You may however manually force a recall of each of the 14 preset modes by pressing the Recall button All preset modes are automatically recalled as the monitor senses the incoming signal The ability to recall the prese...

Page 20: ...es and the power saving operation is indicated by the power indicator on the front panel When the power indicator is green operation is normal When the power indicator is amber the monitor is in a power saving mode If the power indicator is amber press the power button to turn on the monitor If the power indicator is amber and you wish to use the PC again move your mouse pointer or touch a keyboar...

Page 21: ...age Check Signal Cable will be highlighted alerting you to check the signal cable connections DDC is a communication channel over which the monitor automatically informs the host system PC about its capabilities This monitor has DDC function DDC2B carries out uni directional communication between the PC and the monitor Under these situations the PC sends display data to the monitor but not command...

Page 22: ...tom The power LED is illuminated amber Possible causes Display power management mode These is no sync signal The signal cable is not fastened securely Check the computer power and graphics adapter configuration Symptom The image on the SCREEN is not centered too small or too large Possible Causes Image adjustment not been done yet in the current operating mode Use the SELECT and or buttons to set ...

Page 23: ...equent while the monitor is operating It is normal for some monitors to make occasional sounds when being turned on or off or when changing video modes 2 Do not attempt to service the monitor yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 3 When replacement parts are required have the service technician...

Page 24: ...st 6 Red Ground 7 Green Ground 8 Blue Ground Pin Separate Sync 9 NC 10 Ground 11 Ground 12 SDA 13 Horizontal Sync 14 Vertical Sync 15 SCL Use only the AC DC adapter supplied with the monitor Input AC 100 240V 50 60Hz 81 120VA 1 2A Out put DC 24V 1 9A Manufacturer AMBIT Microsystems Corporation Model APA 45AA Type Separate sync H sync H sync V sync V sync ...

Page 25: ...Automatic Vertical Freq 56Hz 75Hz Automatic Input form Separate TTL Positive Negative Signal input 15 pin D Sub connector Video Input Display Area 307 x 230mm Input Form Separate RGB Analog 0 714Vp p 75ohm Positive Resolution XGA 1024 x 768 75Hz max Power Input DC 24V 1 2A Dimensions 15 95 x 7 18 x 14 24inch 405 2 x 182 4 x 361 6mm WxDxH Weight net 5 6kg 12 35lbs Tilt Range Down 5 Up 30 Environmen...

Page 26: ...oblems which result from misuse abuse accident alteration or incorrect electrical current or voltage Therefore these costs are paid by the consumer CUSTOMER ASSISTANCE NUMBERS FOR SERVICE You must call Product Assistance to confirm the product needs servicing and to obtain Return Authorization RA Call 1 800 243 0000 Mon Fri 7AM to 7PM CST Please select the appropriate option on the menu During the...