▪ Luminance: 204 Gray, 80IRE
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
Mode
Coordinate
Temp
△
uv
x
y
Cool
0.271
0.270
13,000K
0.0000
Medium
0.286
0.289
9,300K
0.0000
Warm
0.313
0.329
6,500K
0.0000
▪ Standard color coordinate and temperature using CA-210
(1) LGD , 65”AUO and 50” AUO module
Mode
Coordinate
Temp
△
uv
x
y
Cool
0.269±0.002
0.273±0.002
13,000K
0.0000
Medium
0.286±0.002
0.289±0.002
9,300K
0.0000
Warm
0.313±0.002
0.329±0.002
6,500K
0.0000
(2) O/S Module(AUO, CMI, Sharp,IPS…)
Mode
Coordinate
Temp
△
uv
x
y
Cool
0.271±0.002
0.276±0.002
13,000K
0.0000
Medium
0.286±0.002
0.289±0.002
9,300K
0.0000
Warm
0.313±0.002
0.329±0.002
6,500K
0.0000
▪ Normal line (March ~ December)
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
▪ LGD TN Module(Cool temp Spec is 6500K)
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA4AA Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option.
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
6. GND and HI-POT Test
6.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE insertion
condition
6.2. GND & HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next
process automatically
6.3. Checkpoint
(1) Test voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
- GND Test = POWER CORD GND and SIGNAL CABLE
GND.
- Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
NC
5.0
Aging
time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
286
289
313
329
1
0-2
282
289
297
308
324
348
2
3-5
281
287
296
306
323
346
3
6-9
279
284
294
303
321
343
4
10-19
277
280
292
299
319
339
5
20-35
275
277
290
296
317
336
6
36-49
274
274
289
293
316
333
7
50-79
273
272
288
291
315
331
8
80-119
272
271
287
290
314
330
9
Over 120
271
270
286
289
313
329
Cool
Medium
Warm
x
y
x
y
x
y
spec
286
289
295
305
313
329
target
286
289
295
305
313
329